Operator Control Panel (Digital Engine Controller Only)
The Operator Control Panel is shown in Figure 4-1.
WARNING: Never connect this generator to any buildings electrical system unless a licensed electrician
has installed an approved transfer switch. The National Electrical Code (NEC) requires that
connection of a generator to any electrical circuit normally powered by means of an electric
utility must be connected by means of approved transfer switch equipment so as to isolate
the electrical circuit from the utility distribution system when the generator is operating.
Failure to isolate the electrical circuits by such means may result in injury or death to utility
power workers due to backfeed of electrical energy onto the utility lines.
Figure 4-1 Digital Operator Control Panel
DECREMENT
SILENCE
RESET
SHUTDOWN
ALARM
READY
SPEED SIGNAL
EMERGENCY
STOP
RUN
OFF
AUTO
LOAD
TEST
EXIT
ENTER
LAMP TEST
MICROPROCESSOR ENGINE CONTROLLER
INCREMENT
Vavg
000
Aavg
000
Freq
000
VOLTAGE
ADJUST
–
+
LCD Display
-
Vavg
(average voltage) display 0-999 volts.
Aavg
(average amperage) display 0-999 amperes.
Freq
(frequency) display 0-999 hertz.
Alarm LED
-
Flashes when a fault is detected.
Shutdown LED
-
Flashes when a fault is detected.
Ready LED
-
On when the generator set is ready for automatic operation and no Shutdown or Alarm faults are detected.
Speed Signal LED
-
On when the engine speed signal is detected (i.e. the engine is cranking).
Emergency Stop LED
- On when the Emergency Stop Switch is used to stop the engine.
Emergency Stop Switch
- When pushed, the engine is stopped immediately. The engine cannot be restarted until the controller is reset.
Programming Keys
←
Exit pushbutton used to scroll backward through the status menus or programming prompts to the previous item.
Note: The longer the push-button is held down, the faster the menu prompts appear.
↓
Decrement pushbutton used to reduce a programming value while in the programming mode.
Note: The longer the push-button is held down, the faster the value will be decremented.
↑
Increase pushbutton used to increase a programming value while in the programming mode.
Note: The longer the push-button is held down, the faster the value will be incremented.
→
Enter pushbutton used to scroll forward through the status menus or programming prompts to the next item.
Note: The longer the push-button is held down, the faster the menu prompts appear.
Run Switch
-
When pushed, initiates a manual start signal to start the engine. The engine will start and operate continuously providing no
shutdown faults are active. All protective circuits are operative in this mode. There will be no cool down cycle at the end of a
manual run sequence.
Run LED
-
On when the Run switch is used to start the engine (generator set).
OFF Switch
-
When pushed, sends a stop signal to the engine to stop the engine.
OFF LED
-
On when the OFF Switch is used to stop the engine.
Summary of Contents for GLC30
Page 12: ...2 2 General Information MN2408...
Page 32: ...2 22 General Information MN2408...
Page 42: ...3 10 Receiving Installation MN2408 Figure 3 4 Three Phase WYE and DELTA Connections...
Page 52: ...4 6 Operation MN2408 Figure 4 3 Engine Controller Inputs Outputs...
Page 64: ...4 18 Operation MN2408 Figure 4 4 Configuration Data Sheet j j j j j j j j j...
Page 86: ...A 10 Series GLC MN2408 Figure A 2 Customer Interface Connection Diagram MEC20 MEC2...
Page 87: ...Series GLC A 11 MN2408 Figure A 3 Customer Interface w o Breaker Power Connection Diagram...
Page 88: ...A 12 Series GLC MN2408 Figure A 4 Single Phase w o Breaker Connection Diagram...
Page 89: ...Series GLC A 13 MN2408 Figure A 5 Single Phase One Breaker Connection Diagram...
Page 90: ...A 14 Series GLC MN2408 Figure A 6 Single Phase Two Breaker Connection Diagram...
Page 95: ...Series GLC A 19 MN2408 Figure A 11 Three Phase Connection Diagram...
Page 96: ...A 20 Series GLC MN2408 Figure A 12 Three Phase Connection Diagram with PMG...
Page 97: ...Series GLC A 21 MN2408 Figure A 13 Three Phase Connection Diagram Wire 1 0 and larger...
Page 104: ...A 28 Series GLC MN2408 Figure A 20 Control Box Connections with MEC2 Controller...
Page 105: ...Series GLC A 29 MN2408 Figure A 21 Engine Wiring Woodward 4 3L GM...
Page 106: ...A 30 Series GLC MN2408 Figure A 22 Engine Wiring Woodward 5 7L GM...
Page 107: ...Series GLC A 31 MN2408 Figure A 23 Engine Wiring Woodward 8 1L GM...
Page 108: ...A 32 Series GLC MN2408...