Section 4
Operation
Operation 4‐1
MN2408
Digital Engine Controller Description
EM0046A21 (MRS17)
Figure 4‐8 Operator Control Panel
Stop
Manual
Run
Display
Menu
Group
LED Indicators
Operating Modes and
Horn & Fault Reset
Note: The operator control panel is equyipped with a heater element that allows the LCD display
to operate to -40
°
C (not the entire generator set, see generator specifications). This
heater operates from the main battery power.
LED Indicators
Alarm (red) - Alarm (shutdown) condition occurred. Annunciates & shuts down generator.
Not In Auto (red) - Control is not in auto mode and cannot provide standby power.
Running (green) - Generator is running, no alarms or warnings.
Warning (yellow) - A warning condition has occurred. Annunciates only
.
Ready/Auto (green) - Control is in Auto mode and ready to provide standby power.
Supplying Load (green) - Generator is providing output voltage to load.
Table 4‐8 Alarm & Warning Conditions
Alarm
Warning
X
X
High Coolant temperature
X
X
Low Oil pressure
X
X
Low Fuel level
X
X
Generator Under/Over Voltage
X
X
Generator Under/Over Frequency
X
X
Generator Over Current
X
Generator Overspeed
X
Coolant temperature Low
X
Starting battery Under/Over Voltage
Manual Run
Immediately begins the crank cycle to start engine and produce power (MAN mode only).
Start
Start generator set operation (MAN mode only).
Stop
Stops the Engine and generator set (MAN mode only).
Display
Displays setpoints, adjustments, Alarms and Warning conditions and Operating Mode selections.
Page
Changes menu displayed - Measurement, Adjustment or History.
Mode
A
and
"
Allows selection of OFF - MAN - AUTO mode choices.
Horn Reset
Deactivates the Horn output.
Fault Reset
Reset Alarms and Warnings.
Y
and
B
Selects the menu choice, select the setpoint or select the menu or increase/decrease the
setpoint value.
Enter
Confirm and accept changed setpoint value.
Enter +
Y
and
B
Adjusts display contrast.
Enter+ Fault Reset
Clears engine ECU faults.
Summary of Contents for GLC10
Page 12: ...2 2 General Information MN2408...
Page 24: ...2 14 General Information MN2408...
Page 40: ...3 16 Receiving Installation MN2408...
Page 58: ...4 18 Operation MN2408 Figure 4 15 Engine Controller Inputs Outputs...
Page 70: ...4 30 Operation MN2408 Figure 4 16 Configuration Data Sheet j j j j j j j j j...
Page 74: ...4 34 Operation MN2408...
Page 88: ...A 10 Series GLC MN2408...
Page 90: ...B 2 Series GLC MN2408 Figure B 11 Customer Interface Connection Diagram MEC20 MEC2...
Page 91: ...Series GLC B 3 MN2408 Figure B 12 Customer Interface w o Breaker Power Connection Diagram...
Page 92: ...B 4 Series GLC MN2408 Figure B 13 Single Phase w o Breaker Connection Diagram...
Page 93: ...Series GLC B 5 MN2408 Figure B 14 Single Phase One Breaker Connection Diagram...
Page 94: ...B 6 Series GLC MN2408 Figure B 15 Single Phase Two Breaker Connection Diagram...
Page 99: ...Series GLC B 11 MN2408 Figure B 20 Three Phase Connection Diagram...
Page 100: ...B 12 Series GLC MN2408 Figure B 21 Three Phase Connection Diagram with PMG...
Page 101: ...Series GLC B 13 MN2408 Figure B 22 Three Phase Connection Diagram Wire 1 0 and larger...
Page 106: ...B 18 Series GLC MN2408 Figure B 27 Control Box Connections with MEC20 Controller...
Page 107: ...Series GLC B 19 MN2408 Figure B 28 Control Box Connections with MEC20 Controller Governor...
Page 108: ...B 20 Series GLC MN2408 Figure B 29 Control Box Connections with MEC2 Controller...
Page 109: ...Series GLC B 21 MN2408 Figure B 30 Engine Wiring Woodward 4 3L GM...
Page 110: ...B 22 Series GLC MN2408 Figure B 31 Engine Wiring Woodward 5 7L GM...
Page 111: ...Series GLC B 23 MN2408 Figure B 32 Engine Wiring Woodward 8 1L GM...
Page 112: ...B 24 Series GLC MN2408...
Page 113: ...Baldor District Offices...