Technical data
54 / 55
UF_PS9000_BA_02_1108
14. Technical data
Operating voltage
100-240 V/AC, DC input 18V maximum
2,22A
Operating temperature
-20°C up to +60°C
System of protection (converter)
IP54
Rechargeable battery running time (for a
new and fully loaded rechargeable
battery)
Approx. 3 hours with activated background
lighting; approx. 5 hours with deactivated
backlight.
Weight (converter)
1.5kg
Display LCD
320x240
Dimmable background lighting
Measuring range
-30 up to +30 m/s
Converter dimensions (l x w x d)
265 x 190 x 70 mm
Signal damping
0 up to 100 sec. (adjustable)
Inputs/Outputs
Ultrasonic sensors
2 x BNC, impedance: 50 ohms
Analogue outputs
2x 4-20mA active or passive (adjustable)
(factory adjustment: active 24V/DC), short
circuit proof
Digital output
1x relay, NO (Normally Open),
potential-free
USB mini socket
Type B
2x PT100 (three-wire system)
-
Ultrasonic sensors
Type Pipe
size
Temperature
F20 (2 MHz)
DN10-DN100
-40° up to 150°C
F10 (1 MHz)
DN32-DN400
-40° up to 150°C
F05 (500 kHz)
DN200-DN6000
-40° up to 150°C