4…20 mT Current Output (Current Sourcing)
4 . . . 20 mA
Signal
0V DC
(Ground)
Jumper
Figure 118: 4…20 mA current sourcing output
The current output from the DXN can also be configured to source current . With terminals 6 and 7 jumpered together .
15V DC Supply (30 mT Max)
The DXN has a built in power supply that can be used to power current or voltage sensors external to the meter .
4…20 mT Supply (30V DC Max)
RTD Connections
RTD 2
RTD 1
1000 Ω
1000 Ω
Figure 119: RTD connections
Inputs/Outputs