Digital Outputs
Digital/Pulse Outputs
The digital output is an open collector transistor which must have a pull-up resistor to function . The output can be configured
as either a frequency output scale, based upon the minimum and maximum flow rate chosen, or a totalizing pulse controlled
by the incrementing totalizer .
+ V
External
Pull-Up
Resistor
33 mS
0
+V
Totalizing Pulse - 33 mS Duration
0
+V
On Off
Rate pulse - 1 KHz Maximum
On Time = Off Time
Figure 114: Digital output external power
External
Pull-Up
Resistor
33 mS
0
+V
Totalizing Pulse - 33 mS Duration
0
+V
On Off
Rate pulse - 1 KHz Maximum
On Time = Off Time
Figure 115: Digital output internal power
Inputs/Outputs
Page 85
November 2016
HYB-UM-00090-EN-04