background image

9

SUBJCET TO CHANGE WITHOUT PRIOR NOTICE

    

This product falls within the scope of Directive 2012/19/EU on the management of waste electrical and electronic equipment (RAEE). 

The appliance should not be disposed of with household waste as it consists of different materials that can be recycled at the 
appropriate facilities. Inquire through the municipal authority about the location of the ecological platforms to receive the product 

for disposal and its subsequent proper recycling. The product is not potentially dangerous to human health and the environment, but if 
abandoned in the environment impacts negatively on the ecosystem. The crossed-out bin symbol on the label on the appliance indicates 
that the product complies with the legislation on waste electrical and electronic equipment. The abandonment of the equipment in the 
environment or the improper disposal of the same is punished by law.

7. Information for the correct disposal

8. Technical data

Model

HYDROSONIC M1

Metrological class

R250
R400
R500 (on request)

Flow detection technology

Ultrasonic

Temperature class

T50 cold water ( from +0,1°C to 50°C)

Display

LCD, 8 icons

Protection class

IP68*

Local interface

NFC

Radio standard

- Wireless MBUS EN 13757-4 OMS v4;
- LoRaWAN 1.0.3;
- LoRaWAN 1.0.3 + Wireless MBUS EN 13757-4 OMS v4.

Radio frequency

868 MHz

Radio range / radio power

Wireless MBUS: 300 meters**
LoRaWAN: 5 Km**

Battery life

max 13 years***

Cut-off

The meter does not count volume below 1/3*Q

1

Permitted installations

Any

* IP68: maximum 24 hours continuous immersion at 1 m depth. 

Note: In case of damage caused by accidental impact, the meter must be replaced 
with a new one, to restore the degree of protection.
** In optimal propagation conditions, the radio range depends on physical conditions 
(building construction, climatic conditions...) where the propagation of the radio signal 
can therefore vary.

*** Battery life depends heavily on the working time window, set during the configuration 
process, and the environmental conditions. The battery life estimated is provided by the 
configuration software.

Summary of Contents for HYDROSONIC-M1

Page 1: ...Function 5 Display 5 3 Radio parameters 5 Delivery status 5 Operating mode Radio activation 5 4 Device display loop 6 5 Error message 7 6 Battery and replacement procedures 8 7 Information for correct...

Page 2: ...H mm 90 93 107 114 h mm 20 21 30 28 33 01 Serial number 02 Q3 meter size 03 Measuring class installation positioning allowed RxxH horizontal installation RxxVH vertical and horizontal installation 04...

Page 3: ...itable billing of consumption possible Carefully observe the instructions in the data sheet instruction manual application notes and lid Failure to comply with the operating conditions may result in s...

Page 4: ...ulting from the use of third party seals such as corrosion of seal surfaces and threads Manually and simultaneously screw the meter fittings on both sides and then tighten in opposite directions using...

Page 5: ...ng software Packet data will be transmitted according to the default or NFC settings If the frequency is 200 seconds the transmission is asynchronous otherwise synchronous Transmission frequency confi...

Page 6: ...icon on the display will flash every second If it succeeds the icon will remain fixed and stable otherwise it will turn off It is possible to change the configuration parameters via android NFC devic...

Page 7: ...Historical Day Date 2 not displayed by default 2 seconds CRC 32 ultrasonic firmware legal part 2 seconds Every 130 seconds the display will show the following reduced cycle If an error occurs an error...

Page 8: ...recorded END BATTERY LIFE Low battery Contact supplier NFC FRAUD n Continuous NFC field detected for several consecutive minutes Reset via NFC or LORA RTC P Sudden reset of date and time detected Upd...

Page 9: ...rrect disposal 8 Technical data Model HYDROSONIC M1 Metrological class R250 R400 R500 on request Flow detection technology Ultrasonic Temperature class T50 cold water from 0 1 C to 50 C Display LCD 8...

Page 10: ...O 4064 3 2017 EN 14154 3 2005 A2 2011 OIML R 49 3 2013 EN ISO 4064 5 2017 ETSI EN 300 220 2 v3 2 1 ETSI EN 300 220 1 v3 1 1 ETSI EN 301 489 3 v 2 1 1 ETSI EN 301 489 1 v2 2 3 Welmec Guide 7 2 2020 EN...