The device is available in four types:

Safety conditions

Types

Packing content

Envinronmental conditions

 

Wireless MBUS OMS v4 (output configuration only Wireless MBUS OMS v4)

 

LoRaWAN (output configuration only LoRaWAN)

 

L Wireless MBUS OMS v4 (COMBO, output configuration L Wireless MBUS OMS v4)

 

Hydrosonic water meter

 

Connection gaskets*

 

Connectors*

 

Seal*

 

Storage and transportation: from -20°C to +70°C

 

Operating: from +1°C to +55°C

 

Storage duration does not have to exceed 1 year

 

Water meters are precision devices and they have 
to be protected from shock and vibrations

*depending if ordered with the meter

Read carefully all the instructions before proceeding with the installation! Failure to follow one or more of the procedures contained in the 

manual can be dangerous and cause harm to things and people. Please comply with all applicable safety and accident prevention laws.

Comply with the national regulations on water measurement.

Comply with the technical requirements for the installation of electrical equipment.

The device complies with the requirements of Directive 2014/30/EU of the European Council on electromagnetic compatibility, 

Directive 2014/35/EU on electrical safety and Directive RED 2014/53/EU.

The warranty and validity of the verification before expires if the identification plate and seals attached to the instrument are 
removed or damaged.

Air transportation of tools with active radio interface prohibited.

To clean the device externally use a soft cloth and moistened with water. Do not wash with high pressure jets or immerse the 

device in water. Avoid contact with oils and solvent. Do not use alcohol or detergents.

Remove the product from the package only at installation to protect it from damage and dirt.

If several devices are installed in a unit, the installation conditions must be the same for all devices in order to ensure the most 
equitable billing of consumption possible.

Carefully observe the instructions in the data sheet, instruction manual, application notes and lid. Failure to comply with the 
operating conditions may result in situations of danger and forfeiture of all claims of liability for defects and liability on the 
basis of any guarantees expressly granted. Further information is available on www.bmeters.com

Dispose of replaced devices and defective components in accordance with current environmental regulations.

Do not damage the device casing. In the event of blunt objects hitting the front of the display, it can be damaged irremediably 
and lose the degree of protection IP65 or IP68. Install in areas protected against impact. In case of breakage of the protective 
casing contact customer support.

The meter is not suitable for running water in central heating systems but is suitable for clean water.

Pay attention to sharp edges or sharp projections in the threads, flanges and measuring tube. Therefore, it is recommended 
to wear protective gloves.

After installation of the meter perform a leak test of the system.

The meter must be mounted or removed only after the system has been depressurized.

The meter does not have lightning protection.

Do not expose the meter to sun and heat sources. Do not throw into the fire.

The device shall be used in such a way as to minimise the potential for human contact during normal operation. In order to 
avoid the possibility of exceeding the limits of exposure to radio frequencies, the human proximity to receivers with integrated 

antenna should not be less than 20 cm (8 inches) during normal operation.

Keep away from children.

Water meters do not require special protection against electrical interference; however, electromagnetic 
interference must be avoided.

 Attention

: highlights instructions to be followed scrupulously for the correct operation of the water meter.

 Danger

: the paragraphs highlighted by this symbol contain important information to avoid situations of danger for themselves or for others. 

 Notes

: notes with this symbol contain useful information for better use of the device.

Summary of Contents for HYDROSONIC-M1

Page 1: ...Function 5 Display 5 3 Radio parameters 5 Delivery status 5 Operating mode Radio activation 5 4 Device display loop 6 5 Error message 7 6 Battery and replacement procedures 8 7 Information for correct...

Page 2: ...H mm 90 93 107 114 h mm 20 21 30 28 33 01 Serial number 02 Q3 meter size 03 Measuring class installation positioning allowed RxxH horizontal installation RxxVH vertical and horizontal installation 04...

Page 3: ...itable billing of consumption possible Carefully observe the instructions in the data sheet instruction manual application notes and lid Failure to comply with the operating conditions may result in s...

Page 4: ...ulting from the use of third party seals such as corrosion of seal surfaces and threads Manually and simultaneously screw the meter fittings on both sides and then tighten in opposite directions using...

Page 5: ...ng software Packet data will be transmitted according to the default or NFC settings If the frequency is 200 seconds the transmission is asynchronous otherwise synchronous Transmission frequency confi...

Page 6: ...icon on the display will flash every second If it succeeds the icon will remain fixed and stable otherwise it will turn off It is possible to change the configuration parameters via android NFC devic...

Page 7: ...Historical Day Date 2 not displayed by default 2 seconds CRC 32 ultrasonic firmware legal part 2 seconds Every 130 seconds the display will show the following reduced cycle If an error occurs an error...

Page 8: ...recorded END BATTERY LIFE Low battery Contact supplier NFC FRAUD n Continuous NFC field detected for several consecutive minutes Reset via NFC or LORA RTC P Sudden reset of date and time detected Upd...

Page 9: ...rrect disposal 8 Technical data Model HYDROSONIC M1 Metrological class R250 R400 R500 on request Flow detection technology Ultrasonic Temperature class T50 cold water from 0 1 C to 50 C Display LCD 8...

Page 10: ...O 4064 3 2017 EN 14154 3 2005 A2 2011 OIML R 49 3 2013 EN ISO 4064 5 2017 ETSI EN 300 220 2 v3 2 1 ETSI EN 300 220 1 v3 1 1 ETSI EN 301 489 3 v 2 1 1 ETSI EN 301 489 1 v2 2 3 Welmec Guide 7 2 2020 EN...

Reviews: