background image

8

SUBJCET TO CHANGE WITHOUT PRIOR NOTICE

FREEZING

' F '

A minimum water temperature < 2 is detected. C. 

The activation date is recorded.

Temporary

Automatically when 

the initial condition is 

restored.

MAXIMUM FLOW 

RATE EXCEEDED

' O '

The counter shall operate at a flow rate exceeding 

Q4 for 10 consecutive minutes. The activation 

date shall be recorded. 

Permanent

Reset via NFC 

or LORA.

LEAKAGE

' L '

The meter detects a continuous flow >0.5*Q1 for 

12 hours. The alarm resets when the flow average 

in 5 minutes is below the threshold indicated 

above. The date of the resolved loss will then be 

recorded. The threshold can be set via NFC or 

LORA (minimum 1 hour).

Temporary

Automatically when 

the initial condition is 

restored.

BURST

' b '

The flow rate of the meter remains continuously 

above Q3 for 30 minutes.

REVERSE FLOW

' I '

Continuous reverse flow greater than 200 liters. 

Threshold can be set via NFC or LORA (minimum 

20 liters). The activation date is recorded.

Permanent

Reset via NFC 

or LORA.

NO CONSUMPTION

' c '

Flow detected for 7 consecutive days (minimum). 

Threshold can be set via NFC or LORA.

Temporary

Automatically when 

flow is detected.

RESET

' S '

Device restarted for any external cause.

Permanent

Reset via NFC 

or LORA.

EXCESSIVE 

TEMPERATURE

' h '

An ambient temperature of > 55 ºC is recorded. 

The activation date is recorded.

END BATTERY LIFE

 

Low battery

Contact supplier

NFC FRAUD

' n '

Continuous NFC field detected for several 

consecutive minutes. 

Reset via NFC 

or LORA.

RTC

' P '

Sudden reset of date and time detected.

Update date and time 

via NFC or LORA.

6. Battery and replacement procedures

The water meter constantly monitors the status of the battery (total discharge: 13 years*) and signals the imminent discharge by 
displaying the icon 

 . The report takes place one year before the total download. For replacement contact the manufacturer.

*Battery life depends heavily on the working time window, set during the configuration process, and the environmental 

conditions. The battery life estimate is provided by the configuration software.

The meter uses non-rechargeable batteries that, if misused with, can be potentially dangerous. 
To reduce the risks, you should take the following precautions:

Do not recharge or replace the battery

Do not open, puncture or damage batteries;

Do not short-circuit batteries;

Do not expose batteries to temperatures above 85 ºC;

Do not insert into ovens, crush or cut: these actions could cause an explosion or leakage of flammable gases or liquids.

Do not use naked flames near the device;

Do not put in contact with water;

Do not expose the battery to an extremely low pressure environment which could cause an explosion, a gas or flammable liquids leak;

Always dispose of batteries in compliance with current regulations;

Always use original spare parts authorized by the manufacturer;

Summary of Contents for HYDROSONIC-M1

Page 1: ...Function 5 Display 5 3 Radio parameters 5 Delivery status 5 Operating mode Radio activation 5 4 Device display loop 6 5 Error message 7 6 Battery and replacement procedures 8 7 Information for correct...

Page 2: ...H mm 90 93 107 114 h mm 20 21 30 28 33 01 Serial number 02 Q3 meter size 03 Measuring class installation positioning allowed RxxH horizontal installation RxxVH vertical and horizontal installation 04...

Page 3: ...itable billing of consumption possible Carefully observe the instructions in the data sheet instruction manual application notes and lid Failure to comply with the operating conditions may result in s...

Page 4: ...ulting from the use of third party seals such as corrosion of seal surfaces and threads Manually and simultaneously screw the meter fittings on both sides and then tighten in opposite directions using...

Page 5: ...ng software Packet data will be transmitted according to the default or NFC settings If the frequency is 200 seconds the transmission is asynchronous otherwise synchronous Transmission frequency confi...

Page 6: ...icon on the display will flash every second If it succeeds the icon will remain fixed and stable otherwise it will turn off It is possible to change the configuration parameters via android NFC devic...

Page 7: ...Historical Day Date 2 not displayed by default 2 seconds CRC 32 ultrasonic firmware legal part 2 seconds Every 130 seconds the display will show the following reduced cycle If an error occurs an error...

Page 8: ...recorded END BATTERY LIFE Low battery Contact supplier NFC FRAUD n Continuous NFC field detected for several consecutive minutes Reset via NFC or LORA RTC P Sudden reset of date and time detected Upd...

Page 9: ...rrect disposal 8 Technical data Model HYDROSONIC M1 Metrological class R250 R400 R500 on request Flow detection technology Ultrasonic Temperature class T50 cold water from 0 1 C to 50 C Display LCD 8...

Page 10: ...O 4064 3 2017 EN 14154 3 2005 A2 2011 OIML R 49 3 2013 EN ISO 4064 5 2017 ETSI EN 300 220 2 v3 2 1 ETSI EN 300 220 1 v3 1 1 ETSI EN 301 489 3 v 2 1 1 ETSI EN 301 489 1 v2 2 3 Welmec Guide 7 2 2020 EN...

Reviews: