background image

2

SUBJCET TO CHANGE WITHOUT PRIOR NOTICE

IT-013-20-MI001-2213

1383

SONIC

T50 

T50 

IP68

12345678

Q

Q

33

2,5

2,5

R500

R500

M20

2020

2020

2030

2030

-M1

Via friuli n°3 - 33050 - Gonars (UD) - ITALY

1. Content

Design

SIze

15mm

(1/2”)

20mm

(3/4”)

20mm

(3/4”)

25mm

(1”)

32mm

(1” 1/4)

40mm

(1” 1/2)

L

mm

110 145 165

130

190

260

300

B

mm

98

I

mm 190 225 245

228

288

360

380

440

D

in

3/4”

1”

1”

1”1/4

1”1/2

2”

H

mm

90

93

107

114

h

mm

20

21

30

28

33

01. 

Serial number

02. 

Q3 meter size

03. 

Measuring class/installation positioning allowed: 

RxxH - horizontal installation

 

RxxVH - vertical and horizontal installation

04. 

CE marking

05. 

Type approval number

06. 

Maximum allowed working pressure

07. 

Battery expiration year

08. 

Company address

09. 

Optical interface

10. 

Type

11. 

Manufacturer

12. 

Year of production

13. 

Temperature class

Device Dial

The water meter HYDROSONIC-M1 is a water meter with digital display and ultrasonic flow detection. 

It is available only for cold water.

Functionality

Summary of Contents for HYDROSONIC-M1

Page 1: ...Function 5 Display 5 3 Radio parameters 5 Delivery status 5 Operating mode Radio activation 5 4 Device display loop 6 5 Error message 7 6 Battery and replacement procedures 8 7 Information for correct...

Page 2: ...H mm 90 93 107 114 h mm 20 21 30 28 33 01 Serial number 02 Q3 meter size 03 Measuring class installation positioning allowed RxxH horizontal installation RxxVH vertical and horizontal installation 04...

Page 3: ...itable billing of consumption possible Carefully observe the instructions in the data sheet instruction manual application notes and lid Failure to comply with the operating conditions may result in s...

Page 4: ...ulting from the use of third party seals such as corrosion of seal surfaces and threads Manually and simultaneously screw the meter fittings on both sides and then tighten in opposite directions using...

Page 5: ...ng software Packet data will be transmitted according to the default or NFC settings If the frequency is 200 seconds the transmission is asynchronous otherwise synchronous Transmission frequency confi...

Page 6: ...icon on the display will flash every second If it succeeds the icon will remain fixed and stable otherwise it will turn off It is possible to change the configuration parameters via android NFC devic...

Page 7: ...Historical Day Date 2 not displayed by default 2 seconds CRC 32 ultrasonic firmware legal part 2 seconds Every 130 seconds the display will show the following reduced cycle If an error occurs an error...

Page 8: ...recorded END BATTERY LIFE Low battery Contact supplier NFC FRAUD n Continuous NFC field detected for several consecutive minutes Reset via NFC or LORA RTC P Sudden reset of date and time detected Upd...

Page 9: ...rrect disposal 8 Technical data Model HYDROSONIC M1 Metrological class R250 R400 R500 on request Flow detection technology Ultrasonic Temperature class T50 cold water from 0 1 C to 50 C Display LCD 8...

Page 10: ...O 4064 3 2017 EN 14154 3 2005 A2 2011 OIML R 49 3 2013 EN ISO 4064 5 2017 ETSI EN 300 220 2 v3 2 1 ETSI EN 300 220 1 v3 1 1 ETSI EN 301 489 3 v 2 1 1 ETSI EN 301 489 1 v2 2 3 Welmec Guide 7 2 2020 EN...

Reviews: