Delivery status

Operating mode - Radio activation

The factory setting is on power saving mode. In this mode the radio transmission function is not activated yet, to save battery power during 
shipment and storage in stock. However, the device can count consumption and send errors (e.g. reverse flow for incorrect installation).

This paragraph describes the operating and radio communication parameters of the device. For the WM-Bus transmission, a test function 
can be activated via the NFC interface (only before the passage of ±5 liters), to verify the correct operation of the device. By means of test 
function the device will transmit for 1 minute a standard data packet with a range of 5 seconds between one packet and another. After this 
cycle the device will return to the previous mode, waiting for the passage of ±5 liters.

2. Operation

3. Radio parameters

Display

Note: For illustrative representation purposes.

01

02

03

04

05

06

07

08

09

01. 

Reverse flow direction

02. 

Main display (m

3

) internal decimal places (litres)

03. 

Unit of measurement

04. 

Historical data

05. 

Configuration mode/alarm

06. 

Battery warning symbol

07. 

Radio transmission status

08. 

Test mode

09. 

Flow rate 

Wireless MBUS – OMS v4 certified (output configuration, only Wireless MBUS)

Radio parameters

At the passage of ±5 liters, the meter begins to transmit a Wireless MBUS telegram in T1 mode (synchronous unidirectional transmission).

Preconfigured radio parameters (AMR synchronous mode, OMSv4 certified)

:

These parameters can be changed in Walk-By or Advanced mode via Android app BMetering NFC Config or BMetering software:

Packet data will be transmitted according to the default or NFC settings. 
If the frequency is < 200 seconds the transmission is asynchronous, otherwise synchronous.

 

Transmission frequency: configurabile (minimo 60 secondi) 

 

Transmission span: from Monday to Friday (weekend optional), maximum 12 hours a day 

 

It is possible to select the active transmission for 24 hours only under the following conditions:  

 

Transmission frequency: > 300 seconds (synchronous) 

 

No historical send: Historical package not selectable

 

Encrypting: enabled/disabled 

 

Historical data (12 months and historical storage day) 

 

Transmitted data: 

 

Battery value and percentage

 

Errors

 

Standard (max. 10 bytes): date and time, water consumption data, inverted flow data, instantaneous flow rate,  
water temperature, CPU temperature

 

Extended (max 19 bytes): standard package with the addition of alarm dates (empty pipe, leakage, freezing)

 

Historical (max. 47 bytes): standard package with addition of 12 months previous historical and historical storage day. 

 

Memory day (max. 20 bytes); standard package with addition of memory day 1 and 2 data (date and consumption in litres)

 

Transmission frequency: every 200 seconds

 

Transmission span: every day, from 0 to 24h 

 

Encryption: disabled (default) 

 

No historical data 

 

Transmitted data: Extended package containing errors, battery percentage, reverse flow data, instantaneous flow, water temperature, 
CPU temperature, alarm dates (empty pipe, loss, freezing).

Preconfigured parameters

:

 

Transmission frequency: data rate based (every 12 hours with DR0, every 6 hours with data rate between DR1 and DR5)

LoRaWAN (transmission configuration only LoRaWAN) 

At the passage of ±5 liters, the meter starts transmitting a lorawan telegram compliant with version 1.0.3, class A and will require the 

network server to update the date and time (if available).

Summary of Contents for HYDROSONIC-M1

Page 1: ...Function 5 Display 5 3 Radio parameters 5 Delivery status 5 Operating mode Radio activation 5 4 Device display loop 6 5 Error message 7 6 Battery and replacement procedures 8 7 Information for correct...

Page 2: ...H mm 90 93 107 114 h mm 20 21 30 28 33 01 Serial number 02 Q3 meter size 03 Measuring class installation positioning allowed RxxH horizontal installation RxxVH vertical and horizontal installation 04...

Page 3: ...itable billing of consumption possible Carefully observe the instructions in the data sheet instruction manual application notes and lid Failure to comply with the operating conditions may result in s...

Page 4: ...ulting from the use of third party seals such as corrosion of seal surfaces and threads Manually and simultaneously screw the meter fittings on both sides and then tighten in opposite directions using...

Page 5: ...ng software Packet data will be transmitted according to the default or NFC settings If the frequency is 200 seconds the transmission is asynchronous otherwise synchronous Transmission frequency confi...

Page 6: ...icon on the display will flash every second If it succeeds the icon will remain fixed and stable otherwise it will turn off It is possible to change the configuration parameters via android NFC devic...

Page 7: ...Historical Day Date 2 not displayed by default 2 seconds CRC 32 ultrasonic firmware legal part 2 seconds Every 130 seconds the display will show the following reduced cycle If an error occurs an error...

Page 8: ...recorded END BATTERY LIFE Low battery Contact supplier NFC FRAUD n Continuous NFC field detected for several consecutive minutes Reset via NFC or LORA RTC P Sudden reset of date and time detected Upd...

Page 9: ...rrect disposal 8 Technical data Model HYDROSONIC M1 Metrological class R250 R400 R500 on request Flow detection technology Ultrasonic Temperature class T50 cold water from 0 1 C to 50 C Display LCD 8...

Page 10: ...O 4064 3 2017 EN 14154 3 2005 A2 2011 OIML R 49 3 2013 EN ISO 4064 5 2017 ETSI EN 300 220 2 v3 2 1 ETSI EN 300 220 1 v3 1 1 ETSI EN 301 489 3 v 2 1 1 ETSI EN 301 489 1 v2 2 3 Welmec Guide 7 2 2020 EN...