9
USA
3.11
Additional components
The DSM system comes with additional components to help configure the
system to work best in the operating room.
Aesculap doesn’t provide a sterile drape for the DSM cart. If required, the
sterile drape should meet the following recommendations:
4.
Preparation and setup
Non-compliance with the following instructions will preclude all respon-
sibility and liability in this respect on the part of Aesculap.
►
When setting up and operating the product, adhere to
– national regulations for installation and operation,
– national regulations on fire and explosion protection.
Note
For the safety of patients and users it is essential that the mains power cord
and, especially, the protective earth connection are intact. In many cases
defective or missing protective earth connections are not registered imme-
diately.
►
Connect the device via the potential equalization terminal
j
at the front
of the cart to the potential equalization system of the room used for
medical purposes, see Fig. 5.
Note
The potential equalization lead can be ordered from the manufacturer as
art. no. GK535 (4 m length) or TA008205 (0.8 m length).
5.
Working with the product
5.1
Transport
►
Do not push the product while transporting. Only pull the product,
especially over elevator and door thresholds.
5.2
System set-up
5.2.1
3D display and robotic arm workspace
To help with positioning the DSM in the operating room, the cart dimen-
sions, the minimum and maximum extensions of the 3D display arm, and
the height and maximum extension of the robotic arm are shown below.
Fig. 8
Legend
a
Max. length (arm fully extended)
b
Max. monitor height
c
Min. monitor height
d
Highest point (roll through doors)
e
Radius
Art. no.
Designation
Function
FS095
Mains cord
orange angled
Switzerland
FS096
Europe
FS097
Great Britain and Ireland
FS098
Japan, USA, Canada
PV012SU
DSM sterile drape
Sterile drape for the head and robotic
arm, sold separately. Single use only
PV030
White balance
card
White-balancing the DSM head image
sensors. The reverse side of the card is
used for checking the focus and align-
ment of the DSM head optics.
PV032SU
DUV 400 refer-
ence card
For checking the functionality of the
DUV 400 imaging module (optional).
Single use only for accuracy check
TA015635
Lens cap
Protecting the lens of the DSM head
when it is being stored
Minimum height
30 cm
Maximum height
75 cm
Minimum width
70 cm
Maximum width
115 cm
Additional recommenda-
tions
■
Must not hang over the castors
■
Must not cover the cart vents
WARNING
Risk of injury and/or product malfunction due to
incorrect operation of the electromedical system!
►
Adhere to the instructions for use of any medi-
cal device.
a = 2,34 m
b = 2,03 m
c = 1,47 m
e = 1,24 m
d = 1,86 m