___________________________________________________H3000 Pilot Handbook
HB-3001-02
53
Hydraulic Pumps
Pump unit is shielded from the direct effects of the elements.
Minimise the lengths of the hydraulic lines from the pump to the
cylinder and where possible the pump motor supply cables.
Absence of oil leaks.
Absence of air in the hydraulic system.
Rotary Drives
No backlash or excessive slackness in chains/linkages.
Rudder Reference Installation
Base securely fixed to boat structure.
Arm securely fixed to boss.
Ball joint securely fixed to arm.
Linkage has not been over extended.
No slack or backlash in the linkage.
Linkage does not foul when rudder moved hard over to hard over.
Arm moves through at least 90° when rudder moved hard over to
hard over (there must be at least a 1.0V difference between the end
stops).
Ball joint securely fixed to quadrant/tiller.