Fault 115 – Drive Power Failure: Check Supply
Fault Description
The Pilot processor PCB is unable to communicate with the drive PCB.
Remedial Action
Check to ensure the high current drive supply is present and is of the
correct voltage. It is normal for the drive supply to be on a separate circuit
breaker to the rest of the Pilot electronics, ensure this breaker (if present)
is switched on.
Pilot Display Shows "No Pilot"
Fault Description
No regular messages are being received by the Pilot display (GPD) from
the Pilot computer via the Fastnet network, either the display is not
receiving messages or the Pilot computer is not transmitting them.
Remedial Action
If other displays show Pilot data, check the Fastnet network installation of
the affected Pilot display. If the installation is correct suspect a fault with
the Pilot display unit.
If no Pilot data is available on any display check the installation of the
whole Fastnet network, if there is an instrument system operating on the
same network is that data available on displays? If the installation is
correct, and the instrument system displays are functioning on the same
network, suspect a fault with the Pilot computer.