H3000 Pilot Handbook___________________________________________________
HB-3001-02
102
Fault 110 - No Optimum Wind Data
Fault Description
No Optimum Wind Angle data is being received via the Fastnet network.
Remedial Action
1)
Check the Optimum Wind Angle (OPT W/A) data displayed on the
instrument system.
2)
Check connections to instrument system.
Fault 111 - Current Trip: Drive or Clutch
Fault Description
The current limiting circuit for the drive motor (25A on ACP1, 40A on
ACP2) or the clutch (2A) has tripped.
Remedial Action
1)
Check the installation and wiring for short circuits or loose
connections.
2)
Check the current to the clutch, if this exceeds the maximum value the
fault will occur immediately.
3)
Check the current to the drive motor, if this exceeds the maximum
value the fault will occur immediately.