background image

AB-6387

7

 

„

Installation

 

CAUTION

Install, wire, and use this product under the 

conditions specified by this manual.

Failure to do so may cause fire or device 

failure.

Installation and wiring of the actuator must 

be performed by personnel qualified to do 

instrumentation and electrical work.

Mistakes in installation or wiring may cause 

fire or electric shock.

Do not put a load or weight on this product.

Doing so may damage the product.

 

z

Precautions for installation

Observe the following cautions in order to avoid 
failure of this product.

 

Do not strike or jar this product.

 

Do not install this product near a steam coil or 
pressurized hot-water coil.   

 

  

High-temperature radiant heat may cause failure of 
the actuator.

In addition, observe the following cautions.

 

Install the product in a position allowing easy 
access for maintenance and inspection.

Refer to ■ "Dimensions."

 

If the product is installed in a ceiling, make a 
trapdoor for inspection within 50 cm around the 
valve.

 

z

Mounting position

 

The product can be mounted at any angle from 
upright to sideways  (90-degree inclination)  based 
on the output shaft.    

 

 

 

Do not mount it with the output shaft pointing 
upward.

Figure. 3  Incorrect mounting position

 

z

When using with the control valve

When this product is used with the control valve 

(Models V5063A, 5064A, V5065A, etc.) , use the 

valve linkage  (Models Q455C or Q455D) .

To attach the valve linkage, refer to AB-4051, “

Valve Linkages Mod-

els Q455C, Q455D, Q455F Specifications/Instructions

.”

 

z

When using with the damper

When this product is used with the damper, use the 
damper linkage  (Models Q605A, Q605D, or Q605E) .

To assemble the product, damper linkage, and damper, refer to AB-
4062, “

Damper  Linkages  Q605A,  D  and  E  Specifications/Instruc

-

tions

.”

 

„

Wiring

 

WARNING

Before wiring, be sure to turn off the power to 

this product.

Failure to do so may result in electric shock 

or device failure.

Be sure to ground this product with a ground 

resistance of less than 100 Ω.

Improper grounding may cause electric 

shock or malfunction.

 

CAUTION

Provide a circuit protector  (e.g., a fuse or 

circuit breaker) for the power source.

Failure to do so may cause a short circuit 

leading to fire or device failure.

Install, wire, and use this product under the 

conditions specified by this manual.

Failure to do so may cause fire or device 

failure.

Installation and wiring of the actuator must 

be performed by personnel qualified to do 

instrumentation and electrical work.

Mistakes in installation or wiring may cause 

fire or electric shock.

All wiring must comply with applicable codes 

and ordinances.

Otherwise there is a danger of fire.

Use crimp terminals with insulation for 

connections to the product terminals.

Failure to do so may cause a short circuit 

leading to fire or device failure.

Tighten the terminal screws with the specified 

torque.

Insufficient tightening of the terminal screws 

may cause fire or overheating.

Summary of Contents for MY3000 00 Series

Page 1: ...xerting proportional control when combined with the electric proportional controller such as Neostat Model TY900_Z insertion type temperature controller Model TY9800 4 20 mA DC input type exerting pro...

Page 2: ...sts etc taking into consideration the operating environment conditions and frequency of use as basic parameters The recommended design life of this product is 10 years The recommended design life assu...

Page 3: ...ue Remarks 50 Hz 60 Hz MY3000F0200 24 V AC Nominal 135 feedback potentiometer 160 69 s 58 s 12 5 N m MY3000F0400 35 s 29 s 6 N m High speed motor type MY3000E0200 Nominal 135 resistance Input 69 s 58...

Page 4: ...eedback potentiometer F B potentiometer total resistance nominal 135 Max applied voltage 5 V DC Nominal 135 resistance Input 4 20 mA DC input Input impedance 125 2 10 V DC input Input impedance 1 M or...

Page 5: ...tdoor cover optional parts etc to avoid direct sunlight Mounting position Refer to Installation Mounting position Manual operation Available Refer to Installation Manual open close operation Insulatio...

Page 6: ...ixing the cover Three screws are provided in total Bracket Base for mounting the main body Mounting holes Holes in the bracket for mounting the actuator Mount the actuator with M6 screws Cover Plastic...

Page 7: ...Models Q455C or Q455D To attach the valve linkage refer to AB 4051 Valve Linkages Mod els Q455C Q455D Q455F Specifications Instructions z z When using with the damper When this product is used with t...

Page 8: ...y Switch Unit Optional WARNING Before beginning setup work be sure to turn off the power to this product Failure to do so may result in electric shock or device failure Before setting or engineering w...

Page 9: ...dials A B C D After setting the auxiliary switches check that they operate as intended The operation range of the auxiliary switches is as follows Setting range valve position from 5 to 95 Repeatabili...

Page 10: ...Y3000E0200 4 5 6 7 To controller 24 V AC power Open F G R B W T2 T1 1 3 2 Figure 13 z z 4 20 mA DC input Model MY3000G0200 Model MY3000G9200 4 5 6 4 20 mA DC inputs to controller 24 V AC power or 85 2...

Page 11: ...o the terminal W on either the motor side or the controller side Figure 18 Connection to Neostat z z 4 20 mA DC input Model MY3000G0200 Model MY3000G9200 Model R35TC0 Model R36TC0 Control motor 4 20 m...

Page 12: ...an abnormal condition such as disconnection in the actuator an abnormal input signal failure of the feed back potentiometer due to its product service life the minimum opening position cannot be maint...

Page 13: ...not internally connected 3 Do not implement a daisy chain wiring passing through this product s power terminals Figure 24 z z 2 10 V DC input Model MY3000V0200 Input signals and power are shared Model...

Page 14: ...s Damages on the product Operation status 6 months Check that the valve is smoothly opened or closed Check that no abnormal sound or vibration is observed Regular inspection Whenever necessary Check t...

Page 15: ...AB 6387 15 Disposal Dispose of this product as industrial waste in accordance with your local regulations Do not reuse all or any part of the product...

Page 16: ...n Infilex is a trademark of Azbil Corporation Specifications are subject to change without notice http www azbil com 1 12 2 Kawana Fujisawa Kanagawa 251 8522 JAPAN Building Systems Company 16 AB 6387...