OPERATION MANUAL BD/TL
31
__________________________________________________________________________________________________________________
-
OFF
– charging accumulator turned off,
-
On
– charging accumulator on,
-
LEVEL
– charging status readout in %.
AutoOF
scale automatic off function settings:
- OFF – scale doesn’t turn off,
- ON – scale turns off after 5 minutes without actions (no load change or using
keys),
- bAtt – as above but only when supplied from accumulators.
FIrMW
firmware actualization (service),
dEFAUL default settings
Maintenance and repairs of small defects
1.
The scale should be kept clean.
2.
Take care that no dirt gets between the platform and the scale base. If found
any, remove the pan (lift it up), remove dirt and then replace the pan.
3.
In case of improper operation caused by short-lasting power supply decay,
unplug the scale from the mains and then plug it again after few seconds.
4.
It is forbidden to make any repairs by unauthorised persons.
5.
To repair the scale, please contact our nearest service. List of authorized
services is shown on site: www.axis.pl.
6.
Damaged scales should be sent to repair in original package only. Scale should
be protected against pressure.
Error communicates:
Communicate
Possible cause
Remedy
C-1
...
6
(over 1 min.)
self test failed
if displayed more than 1 minute,
contact an authorised service
balance
doesn’t work
protection rod
remove protection rod and cap
L
pan missing
put the pan on
mechanical damage
contact an authorized service
H
overloading
remove the load from the pan
mechanical damage
contact an authorized service