28
OPERATION MANUAL BD/TL
__________________________________________________________________________________________________________________
- totAL
ModE
totAL register measurement confirmation mode:
manual (MAnUA) –after pressing
∑
key,
automatic (Auto) – after indication stabilization,
totAL work with (On) printout or without (OFF),
SAVE
totAL summing register saved to non-volatile memory (On) or reset
after each turning off the scale (OFF).
- thr
Function allows for comparing weighing result with two programmed thresholds
values P1 (Lo -lower) and P2 (Hi - upper). Comparing result is signalized by
Lo
,
Ready
or
Hi
marks on display.
oFF
threshold function off,
on
threshold function on (run), threshold values edition
(SEt Lo, SEt HI, SEt Zr),
threshold values printout,
ModE
threshold function work mode: net mass (MASS) or pieces quantity
(PCS),
outPut
transoptors out working mode:
standard impulse (IMPULS) or signalizator (SIGnAL)
mode
SIGNAL.
: mode
IMPULS
:
If the scale is additionaly equipped with threshold outputs (option) in
IMPULS
mode on outputs P1 (threshold I) and P2 (threshold II) short-circuit impulses
appear for about 0,5s. On output P3 (zero) short-circuit state appears with the
zero threshold indication.