Section 2: Basic Installation
16
AXIS StorPoint CD User’s Manual
Note:
❏
However, if you are using two separate towers, we recommend
that the cable from the StorPoint CD/T to the second tower
complies with the following maximum cable length requirements:
• The ribbon cable from the StorPoint CD/T to the connector
leaving the first tower should not exceed 60 cm.
• The cable connecting the two towers should not exceed 50 cm.
Caution
0
Always make sure that power is
not
connected to the StorPoint CD or
any of the CD-ROM drives when making changes to the SCSI chain.
The SCSI bus may become damaged if you connect or disconnect any
units when the power is on.
Connecting the
SCSI Drives
To connect the SCSI drives to the StorPoint CD, follow these steps:
1.
Connect the SCSI cable to the SCSI connector on the StorPoint
CD.
2.
Connect the SCSI cable to the CD-ROM drive(s).
3.
Set a unique SCSI address 0 through 6 for each of the connected
CD-ROM drive(s). The Dual SCSI version has two separate buses
with addresses 0 through 6 available on each. Refer to the CD-ROM
drive documentation for instructions on how to set the SCSI
address.
Note:
❏
The SCSI address of the StorPoint is 7, and cannot be changed.