15. Unpack the balance. Attach meter to the wall or desktop, choosing one of three methods.  

 
 

 
 
 

 
 
 
 

 
 
 

 
 
 

16. Connect the supply cable plug to socket with protective contact with unloaded balance, which will cause 
autotests performing and after indication stabilization displaying of sero indication 

9.

 

Balance test

 

During  balance  operation,  in  order  to  confirm  its  efficiency,  it  is  recommended  to  check  the  weighing 

precision by putting and object of exactly known weight before and after series of measurements.  

For testing of verified balances use weight standard, having  valid standardization certificates. In case of 

allowable  measurement  error  exceeding  contact  authorized  service  company  to  perform  balance 
adjustment.  

Balance  adjustment  must  be  performed  by  authorized  service  company  only,  as  it  is 

connected with necessity of seals breaching, required for warranty purposes. 

Summary of Contents for 4BA SERIES

Page 1: ...USER MANUAL 4BA N 4BANA N 4BAF N 4BAPZ N and 4BAPA N SERIES File 2016 04 19 4BAxx bE0109 GB ...

Page 2: ...foundation 19 8 3 2 Scale installation 21 9 Balance test 22 10 Accumulator change ME 01 option 23 11 Scale with ME 01 meter keys and indicators 24 12 Operation principles 26 13 Start up 27 14 Weighing with tare 28 15 Scale menu 29 16 Menu navigation rules 30 17 Scale setup SEtUP 35 17 1 Scale calibration CALIb 37 17 2 Autozeroing function AutoZEr 38 17 3 Weight unit selection UnIt 39 17 4 Serial p...

Page 3: ...8 8 Total weight function totAL 57 18 9 Checkweighing function thr 59 18 10 Setting date and time function dAtE 62 18 11 Radio communication channel choice function rF CHn 63 18 12 Charging accumulators function bAttErY option 64 18 13 Automatic switching off the scale function AutoOFF 65 18 14 Statistical calculations function StAt 66 18 15 Paperweight calculation PAP 69 19 Maintenance and repair...

Page 4: ...ording to order balances may be verified or calibrated EC verification conformity assessment of balances is required for special applications trade tariffs pharmacy recipes medical and pharmaceutical analysis packing of goods For other applications it is recommended to replace verification with calibration Verified balances have the following verification features protection stamps located on bala...

Page 5: ...meter in aluminium A housing and LCD display 18mm digits height Full set of special functions chapter 15 and standard set of keys ME 01 N18 LED Standard universal ME 01 meter in stainless steel housing and LED display 18mm digits height Full set of special functions chapter 15 and standard set of keys ME 01 N LCD Standard universal ME 01 meter in stainless steel housing and LCD display 18mm digits...

Page 6: ...ousing SE 03 N LCD surcharge designed to cooperate with label printer numerical keys stainless steel housing SE 12 N 2xLCD surcharge designed to operate with computer through RS485 or LAN network with possibility to connect scanner and label printer options 2 displays digit weight indication and text menu and data stainless steel housing SE 22 N 2xLCD meter surcharge one ingredient or multi ingred...

Page 7: ... 1kg 2kg Verification graduation e 100g 200g 500g 1kg 1kg 2kg Minimum load Min 2kg 4kg 10kg 20kg 20kg 40kg Tare set range 300kg 600kg 1500kg 2000kg 3000kg 6000kg Precision class III Operational temperature 10 40 C Weighing time 3s Platform dimensions Balance weight 1000x1000x80 85 mm 60kg 1250x1250x80 85 mm 100kg 1500x1500x80 85 mm 140kg 1500x1500x112 110 mm 150kg 1500x2000x112 110 mm 190kg Displa...

Page 8: ... backlighting and 16h without Indicator protection rating 4BA NA no IP 4BA NAN stainless scales IP65 Sensors protection rating 4BA NA IP67 4BA NAN stainless scales IP68 Pallet scales 4BA PA oraz 4BA PAN Scale type 4BA300 PA N 4BA600 PA N 4BA1000 PA N 4BA1500 PA N 4BA2000 PA N 4BA3000 PA N Maximum load Max 300kg 600kg 1000kg 1500kg 2000kg 3000kg Reading graduation d 0 1kg 0 2kg 0 5kg 0 5kg 1kg 1kg ...

Page 9: ...h with display backlighting and 16h without Scale weight 40kg Indicator protection rating 4BA PA no IP 4BA PAN stainless steel IP65 Sensors protection rating 4BA PA IP67 4BA PAN stainless steel IP68 Foundation scales 4BA F and 4BA FN Balance type 4BA300F N 4BA600F N 4BA1500F N 4BA2000F N 4BA3000F N Maximum load Max 300kg 600kg 1500kg 2000kg 3000kg Reading graduation d 100g 200g 500g 1kg 1kg Verifi...

Page 10: ...nly To avoid fire risk use a feeder of an appropriate type supplied with the scale Pay attention that supply voltage is compatible with specified technical data Do not use the scale when its cover is opened Do not use the scale in explosive conditions Do not use the scale in high humidity If the scale seems not to operate properly unplug it from the mains and do not use until checked by authorised...

Page 11: ..._____________________________________________ 7 Scale external outputs ME 01 meter in aluminium housing RS232C WY Extensometer 12V 1 2A RxD receive TxD transmission mass housing RS232C 1 2 3 4 5 6 7 8 9 P2 threshold 2 P1 threshold I P3 threshold ground housing WY option 1 2 3 4 5 6 7 8 9 Feeder ...

Page 12: ..._________________________ ME 01 meter in stainless steel housing Separate ground connection scales in stainless steel version must be connected using additional conductor Extensometers are connected permanently RS232C Extensometer Power unit 12V Feeder USB Ground RxD receive ground housing RS232C 1 2 3 4 5 6 7 8 9 ...

Page 13: ... set in special funcion LabEL Set of send data is set using special function PrInt The following data can be send Header scale type Max d e serial number Operator identification number Successive printout number measurement Identification number or product bar code Number of pcs PCS function only Single detail mass PCS function only Nett weight Tare package mass Gross weight Total mass Total funct...

Page 14: ...es the same as SI commad Readout of stabilization indicator and actual indication Computer Scale Sx3 CR LF initiaton signal Scale Computer scale send indicator S stable or U unstable 16 bytes the same as SI command Attention Network number different than zero SErIAL nr function changes scale working mode communication with a computer is possible after logging the scale in with 02h scale number com...

Page 15: ...of digits after dot should be the same as on scale display Scale Computer without response Example in order to set low threshold 1000g in scale B1 5 d 0 5g the following order should be sent S L 1 0 0 0 0 CR LF 53h 4Ch 31h 30h 30h 30h 2Eh 30h 0Dh 0Ah in order to set low threshold 100kg in scale B150 d 50g the following order should be sent S L 1 0 0 0 0 CR LF 53h 4Ch 31h 30h 30h 2Eh 30h 30h 0Dh 0A...

Page 16: ... variable signs mm gg 5 signs minutes hour rrrr mm dd 10 signs year month day masa 10 signs scale indication mass unit P1 Steering instruction Attention 1 Except variable signs constant signs can also be inscribed e g factory name product name and so on 2 In standard only one label pattern is possible to printout number 0001 Using bigger amount of patterns other label numbers is possible thanks to...

Page 17: ...scales 1 Unpack balance remove protective foils 2 Place balance on flat horizontal foundation in place not subjected to mechanical vibrations and strong air movements 3 Air bubble in level should be located in the middle position Good Bad 4 Attach meter to the wall desktop or tripod option choosing one of three methods 5 Connect the supply cable plug to socket with protective contact when balance ...

Page 18: ...ur legs 3 Air bubble in level should be located in the middle position Good Bad 4 Lift scale corners up and put locks under in such way that scale legs go into prepared holes 5 Mount locks permanently to the ground using 10 holes 6 Put balance approaches drives on settling them into locks 7 Unscrew transport handles mounted for transport 8 In hermetic scales plug not used joints with supplied caps...

Page 19: ...e at least 50 mm 6 Keep the area free from reinforcing bars as shown in fig 2 on page 8 7 Foundation external and internal dimensions proper for various platform dimensions are shown in table below Balance type Platform dimensions mm Foundation internal dimensions WxLxH mm Foundation enternal dimensions WxL mm 4B300FN 800x800 820x820x128 1220x1220 4B300FN 1000x1000 1020x1020x128 1420x1420 4B300FN ...

Page 20: ...ove 300 70 180 180 65 65 300 210 210 Stopy pod nóżki wagi 200 Rama fundamentu z kotwami 60 Kolektor do odprowadzenia wody Rura z PCV na przewód Obszar wolny od prętów zbrojeniowych Rama fundamentu z kotwami Miejsca na kotwy ramy Feet under balance legs Foundation frame with anchors Water collector PCV pipe for cable Places for frame anchors Area reinforcement bar free Foundation frame with anchors...

Page 21: ...on so legs 7 fit vertically in the limiters 4 holes 6 Place upper plate on balance structure and lightly screw in the fixing screws 7 Check the upper plate location in the foundation level in relation to foundation edge and distance from the edges fig 1 8 When needed shift the plates 5 or put spacers beneath them made from sheet with dimensions of plate 9 If the position of upper plate is correct ...

Page 22: ...ing of sero indication 9 Balance test During balance operation in order to confirm its efficiency it is recommended to check the weighing precision by putting and object of exactly known weight before and after series of measurements For testing of verified balances use weight standard having valid standardization certificates In case of allowable measurement error exceeding contact authorized ser...

Page 23: ...__ 10 Accumulator change ME 01 option 1 Remove screws 11 holding plate 12 remove the plate 2 Take out container with accumulators 13 and place 4 AA format accumulators The way of packing accumulators into the container is shown on the figure on the left and is also shown on the container 12 11 13 RS232C WY Tensometr 12V 1 2A Extensometer ...

Page 24: ...after using T key MODE 19 special function menu turning on indicator B G 20 gross weight after using TARE and key AUT 21 autotare function on T 22 tare memory function on TOTAL FILTER SUM 23 special functions indicators ct n g m2 lb mg 24 unit indicators pcs 25 pieces counting indicator n 26 measurements quantity indicator total function OFF 27 scale turned off standby MIN 28 weighing result under...

Page 25: ...bilization indicator NET 43 net weight after using T key W1 44 first range on in two range scale W2 45 second range on in two range scale HOLD 46 indication locked concerns LOC and UP functions FUNC 47 special function turned on PCS 48 pieces counting g kg lb unit 49 weight unit g gram kg kilogram lb pound unit other MIN 50 weighing result under threshold I thr function OK 51 weighing result betwe...

Page 26: ...placed in the platform centre Do not drop weighed objects on the platform Do not overload the balance over 20 of maximum load 4 The weighing result should be read during the indicator lighting which indicates the result stabilization 5 When there is no weighing but the balance should be ready for operation it may be switched off by I key It causes the balance reading system deactivation end enteri...

Page 27: ..._______________________ 13 Start up Leave the pan empty plug a scale to the mains with a ground contact The scale proceeds with following start up actions Display test Meter type displaying Program version The scale is now ready to work Attention Displaying program version means positive result of all tests 0 0 kg kg ...

Page 28: ...y Zero indication and 0 indicator mean that the scale is ready to work After putting container package tare the scale using T key NET indicator will show up Put on weighted object and readout net weight NET indicator shows that scale indicates net weight In order to readout gross weight press key B G indicator shows that scale indicates gross weight Press again key in order to come back to net ind...

Page 29: ...In out of the box scale after pressing MENU key only SEtuP option it contains all configuration options is available One of the configuration options is Menu that is used to create personalized menu To add a function to personalized menu press T key when the function is indicating Chosen function is indicated with o sign on the left side of display After adding all necessary functions press out in...

Page 30: ...nds and then the scale sequentially displays next menu positions Choosing menu position option is done by pressing T key when it is displayed on the screen After choosing position option usually several options show up on turning on selected option OFF turning off out out to menu Accelerated working with menu Menu first position is displayed for about 7s During this time user can view next positio...

Page 31: ...ey working method During standard weighing key is used to switch between net and gross indication When special function e g PCS is turned on using key enables to go back to standard weighing mode Sign o on the left side signalizes that special function is turned on and user can go back to function mode by pressing key 0 0 0 kg 0 0 0 kg kg kg ...

Page 32: ... normal weighing temporary 5s readout resolution increase is possible Return to normal indication is made automatically Inscribing numerical values Inscribing numerical values is needed in some special functions e g tArE function requires to inscribe tare values Keys 0 increasing digit value decimal point T next digit position MENU end of inscribing 0 0 kg kg 5s 0 kg ...

Page 33: ...ation exit autozeroing autozeroing on autozeroing off lasts 10min exit settings creating menu added to menu choosing product choosing user pieces counting function actual unit selection percentage conversion function animals weighing function tare memory bank maximum value function force and torque value function summation series of measurements function threshold values comparing function statist...

Page 34: ...ansmission type Stab no StAb Auto Cont rEMoVE protocol LonG EPL EPL_A EPL d PEn 01 cooperation with barcode readers MJ 4209 port 2 as above printout data configuration transmission port 1 header scale type Max d e serial nr scale operator id number user name succesive printout measurement number product identification number product barcode number product name pieces quantity PCS function product ...

Page 35: ...____________________________ bAttEry AUto OFF ZEro dEFAULt SErVICE out turn on off accumulator charging if the scale is equipped with accumulator automatic turning off saving accumulator power as above scale start zero inscribing factory zero restore default settings for all options options only for service exit ...

Page 36: ...d user menu CALIb scale sensitivity calibration AutoZEro ing self maintaining zero indication unloaded scale UnIt weight unit selection SErIAL setting serial ports Print transmission printout data selection FILtEr anti disturbance filter b_LIGHt backlight setting Ad420 analogue out configuration FIrMW are updating software only for service dEFAULt reset to factory settings sample of using in chapt...

Page 37: ...CAL StP calibration with external weight confirmation of succesive steps MENU key out leave without changes Press T key when CAL StP option appears calibration in two steps Press T key when weight value used for calibration is indicating or use othEr option and inscribe proper value keys 0 T Press MENU and wait for writing zero to the scale When LOAD message appears put standard of mass on the pan...

Page 38: ...able zero indication if the pan is empty or if zero indication was acquired by pressing T key To turn on the function use MENU key and using T key choose AutoZEr and then Aut on To leave the function press MENU key then with T key chose AutoZEr and Aut OFF Note 1 AUt sign occurs only in scales with LCD display 2 In scales with 0 key active function changes name into AutoZE autozeroing and works on...

Page 39: ...1mg 0 001g milligram KGrAM 1kg 1000g kilogram Pound 1 lb 453 592374g English pound OunCE 1oz 28 349523g ounce OunCEt 1ozt 31 1034763g pharmaceutical ounce GrAIn 1gr 0 06479891g grain PennYW 1dwt 1 55517384g jewellery mass unit GrAM 1g gram The way of choosing carats as weighing unit is shown on the example Attention In scale with LED display designations of mass units lb kg oz ozt ct are not displ...

Page 40: ...har bitS 7 8 parity control PArItY nonE no control Odd nonparity Even parity control scale number in network nr if the scale doesn t work in network the number must be 0 transmission through serial interface SendInG StAb transmission after key is used and result is stable noStAb transmission after key is pressed without need of stabilisation Auto automatic transmission after load is put on and res...

Page 41: ...sult PCS function APW unitary mass PCS function netto net mass tArE current tare value GroSS gross mass totAL total mass totAL function In printout configuration user can set if measurement printout number is saved after turning off the scale or not Enter option Print and choose Prn no Following options will appear rESEt resetting zeroing measurement number counter SAVE activate saving measurement...

Page 42: ...intout during normal weighing with clock option all printout positions deactivated Sample printout during normal weighing some printout positions activated 20 07 kg 20 04 kg 20 04 kg 20 07 kg 2012 11 08 10 01 20 04 kg 2012 11 08 10 01 20 04 kg 2012 11 08 10 01 BA30 MAX 30kg e d 0 01kg S N ID OPER 000001 DATE 2012 11 08 TIME 12 26 NO 3 ID PROD 01 COUNT 0 PCS APW 0 000 g NET 3 08 kg TARE 0 00 kg GRO...

Page 43: ...g the work mode of scale display backlight b_L OFF switch backlight off b_L on switch backlight permanently on b_L ECO switch off after 30 seconds of inactivity no load changes and no key operation b_L bAt like above but when powering from accumulators only out out without changes Switching backlight off causes decrease of energy consumption by the scale what is important during powering from accu...

Page 44: ...__________________________ 17 7 Analog out configuration AnALoG This option enables to set up analog out 4 20mA or 0 10V working method used e g in PLC regulators AnG rnG inscribing Max value AnG CFG working mode configuration PLUS workmode for only positive values MinuS only for negative values both for both 0 kg ...

Page 45: ...ess MENU key When ZErO is displayed press T key On the display a sign ZEr Cod will show up momentary and the a dash on last digit position To enter code in new scale 1234 use keys 0 increasing digit T next digit MENU end of inscribing The following options appear successively on display ZEr Cod enter new secure code value ZEr SEt enter new zero value Using T key choose ZEr SEt Direct result from A...

Page 46: ...tArE maximum value indication function UP force measuring function nEWton statistical calculations StAt paperweight calculation function PAPEr and functions that require additional equipment to be completely functional option with accumulator supply Setting accumulators charging bAttErY Automatic switching off scale function AutoOFF options with the clock 53 setting current date and time function ...

Page 47: ... datasheet form where each product has one row and each column have product data This way created database saved in csv extension with semicolons can be send to scale using Scale Database software and scale s serial interface Scale Database is available on our webpage www axis pl en Database and possibility to cooperate with external devices printer label printer barcode reader and computer enable...

Page 48: ...tabase then no communicate appears the scale stores id barcode number temporarily in memory and enables to send it to the port to printer computer together with actual weighing result LIMIt searching through products from database if product is found then Found communicate appears and all product data is recalled if there is no product in database then not Found communicate appears Prn_P sending a...

Page 49: ...ode from outside the base accepted Std mode not Found barcode from outside the base not accepted and no product is selected LIMIt mode Found product barcode found in database and data recalled Attention If the scale doesn t indicate any communicate check barcode reader connections port configuration and transmission protocol SErIAL function Other fast way is to press and hold MENU key about 3s Pro...

Page 50: ...ling product is equivalent with choosing corresponding label number If database is not used proper label can be choosed using LabeL option To each weighing results transmission a set of product and user identification data is added The set is activated in Print option Available data from products and users base Print SEtuP option USEr Id user identification number USEr nA user name inscribed from ...

Page 51: ...PCS APW set unitary mass directly PCS rS inserting number of details in a sample and receiving of their mass from other scale connected by RS 232C It is advised that single piece weight is not less than one reading unit and sample weight used in first phase is bigger than 100 reading units To leave function press MENU key and then using T key chose PCS and PCS oFF Note 1 APW too LOW communicate si...

Page 52: ...100 second phase measuring specific sample as a percentage of the reference sample Weighing result is displayed in different format depending on the weight value of reference sample The function has the following options PEr oFF disable the function PEr on set current scale indication as 100 and activate percentage weighing out exit without changing settings Note 1 PEr Err message informs that ref...

Page 53: ... user should be saved in scale memory according to printer manual Label pattern choice is made by inscribing label number using LAbEL function Press MENU button When LAbEL is displayed press T key Actual label number will show To enter new label number press T key to exit function without number change press MENU To inscribe label number use keys 0 digit increase T next digit MENU end After enteri...

Page 54: ...ing the scale LOC Prn the measurement initiated manually by pressing key When LOC on is displayed press T key Tare the scale using T key if necessary and place the animal on the pan Wait until the weighing result is averaged scale display blinks Then scale will show stable averaged result and will send it through serial port The result remains on display for about 30 second Important notes 1 The l...

Page 55: ...is function allows holding maximum or minimum value that is indicating at the moment Before measurement scale should be tared Function has following options UP oFF function off HIGH holding maximum value LOW holding minimum value Pressing T key will cause result zeroing Note Autozeroing function and the stabilisation indicator are deactivated when UP function is running 0 0 kg kg 1kg ...

Page 56: ...ivation causes displaying result in force units N Press MENU key Using T key choose NEWto function Function has several options nEW oFF function off nEW on measurement in Newtons ArM torque measurement arm length should be inscribed in meters using T 0 and MENU keys Attention Units convertion from mass kg to force N is made for acceleration of gravity g 9 80665m s2 Note 1N 0 1019kg 0 kg 0 ...

Page 57: ...ot working with receipt printout after each measurement tot working without receipt printout tot CFG saving measurement mode using key Manual after taking off the load auto Press T key when tot is displayed Perform measurement series by pressing key for storing results into total register In order to print and display results enter the function by choosing totAL and tot Prn option from menu The re...

Page 58: ...eceipt form Report form total weight number of measurements average weight Note When the scale doesn t have an internal clock Date and Time do not appear on printout Maximum number of measurements is 99 999 Maximum total load 99 999 000d The weighing unit of the total value from the register Total is the same as the weighing unit stated on the keypad or is 1000 times greater what is signalled by o...

Page 59: ...ignal greater than upper threshold the scale signals MAX red colour long sound signal The checkweighing results can be use to control optical indicator Indication mode batching devices Batching mode Standard scale is set for cooperation with optical indicator On outputs P1 P3 Relays socket short circuit states appear as result of comparison scale indication with threshold values On the chart below...

Page 60: ...g T key The following options for entering thresholds are displayed SEt LO set lower threshold value SEt HI set upper threshold value SEt ZEr set zero signalisation threshold Using T key select SEt LO option Set lower threshold value using the following keys 0 digit increase decimal point T move to next digit MENU finish Then select SEt HI option and enter upper threshold value Choosing SEt ZEr op...

Page 61: ...des e g 1N4148 It is advised to use MS3K P electronic board sold separately consisting of RM96P transmitters with DC24V input voltage and AC250V 3A output Important notes 1 After switching the scale on both thresholds are set to maximum values 2 When setting upper threshold value pay attention that its value is not below lower threshold value 3 Setting lower and upper threshold value is possible a...

Page 62: ...dAt SEt change current date and time dAt PIn data and time secure password to prevent from changing date and time by unauthorized personel dAt For data printout in different format The example at the left presents how to set current date and time using dAt SEt option After setting proper date and time activate it with dAt on option Date and time format PL rrrr mm dd gg mm UE dd mm rrrr gg mm USA m...

Page 63: ...he scale and a pilot In scale and in pilot the same radio channels must be chosen Function should be used when communication is disturbed by other devices that use the same communication channel Press MENU key and choose rF CHn by pressing T key The following communicates will appear on display Na wyświetlaczu pojawią się kolejno CHn 01 channel 1 CHn 02 channel 2 CHn 16 channel 16 out out without ...

Page 64: ... during work with feeder and checking their power level The function has the following options bAt OFF charging off option required if ordinary batteries are used bAt on charging on accumulators are being charged even after switching scale off using I key bAt VoL reading power level of accumulators in go back to mass indication pressing MENU key out leave without changes An attempt of charging ord...

Page 65: ... is helpful in scales supplied from accumulators The function causes scale to switch off automatically Press MENU key When AutoOFF is displayed press T key The following options appear successively on display AOF oFF deactivate function AOF on activate function scale turns off after 5 minutes of not making any actions AOF bAt as above but only when supplied from accumulators Out out without change...

Page 66: ...cur after the scale is loaded and its indications stabilize After each loading printout is made with number of measurements result date and time if clock is installed and the function is activated For the obtained measurements series the scale evaluates n number of samples sum x sum of all samples n x x sum _ x average value sum x n min minimal value from n samples max maximal value from n samples...

Page 67: ...bing tolerance in Sta tAr automatic tare on off StA CFG function configuration Auto Automatic work samples are confirmed after loading the scale and indication stabilization ManuAL manual work confirmation is made by pressing key out exit from function Remember first to inscribe nominal weight value and tolerance mentioned above After that push T key when StA o is displayed Put on successive objec...

Page 68: ...ERAGE average weight as Total n MIN minimum weight in n samples MAX maximum weight in n samples ST DEV standard deviation ST DEV standard deviation percentage To finish work with this function and zeroing result register press MENU key and then when StAt and Sta oFF is displayed press T button Statistics function cooperation with computer and Printer Scale can be equipped with two serial ports mar...

Page 69: ... Menu To enter the function press T key when PAPEr is displayed Following options show on the display PAP oFF turn off the function PAP on turn on PAP n inscribing number of paper pieces on pan PAP ArE inscribing surface of single piece in m2 Press T key when PAP n and PAP ArE is displayed Enter number of samples using 0 increasing digit T next digit MENU end of inscribing Press T key when PAP ArE...

Page 70: ...repair the scale please contact our nearest service Error communicates Communicate Possible cause Remedy C 1 6 over 1 min selftests failed if displayed more than 1 minute contact an authorised service unLOAd SErvic e the scale was switched on with loaded pan remove a load from the pan mechanical damage of the load cell contact an authorised service L pan missing put the pan on mechanical damage co...

Page 71: ... 4BA2000PZ 4BA3000PZ 4BA300PZN 4BA600PZN 4BA1000PZN 4BA1500PZN 4BA2000PZN and 4BA3000PZN 4BA300F 4BA600F 4BA1500F 4BA2000F 4BA3000F i 4BA6000F 4BA300FN 4BA600FN 4BA1500FN 4BA2000FN 4BA3000FN i4BA6000F marked with CE mark comply with the following 1 Directive 2004 108 EWG electromagnetic compatibility and harmonized norms EN 61000 4 3 A1 2008 A2 2011 EN 61000 6 3 2008 A1 2011 2 Directive 2006 95 WE...

Page 72: ...tion Conformity evaluation for the Directive 2006 95 WE and 2004 108 WE was carried out by Research Laboratory of Electrotechnology Institute Division Gdańsk accredited by PCA Conformity T7950R0 evaluation was carried out by NMI Certin B V Notified Body No 0122 Per pro Director of AXIS Sp z o o Production Manager Jan Kończak ________________ Date 30 10 2015 ...

Page 73: ...ge 55 Max1 50 of maximum load mostly 56 Max2 100 of maximum load and adequate reads digit d1 i d2 d1 d2 Double range options causes change of scale s operation after turn on in small mass range 0 Max1 scale displays result with reading unit d1 57 when the load pass the Max1 scale changes reading unit on d2 from this moment scale displays result with reading unit d2 on all measure range 0 Max2 58 r...

Reviews: