background image

Conting Scale

User Manual

Summary of Contents for HCS Series

Page 1: ...Conting Scale User Manual ...

Page 2: ...ecifications 4 Display 4 Controls 5 Packing List 6 Unpacking 6 Installation 6 Getting Started 7 Calibration 7 Zero 7 Tare 7 Unit Conversion 7 Counting Function 8 Accumulation Alarm Function 9 LP50 Print Mode Setting 11 RS232 Printout Settings 12 Cleaning 13 Troubleshooting 14 Factory Testing 15 Company Information 16 ...

Page 3: ...he weighing pan Allow the balance to warm up for 15 20 minutes before using Do not exceed the maximum capacity of the balance If OVER appears on the display the balance is overloaded Remove objects until the amount to be weighed is less than the maximum capacity of the balance Installation and Use Location The balance s working environment should be between 40 F and 105 F Install the balance on a ...

Page 4: ...etc Stabilization time 5 seconds Functions Weighing Counting Zero Tare Print Sensor Load cell Materials ABS body stainless steel double layer weighing pan Calibration External Maximum capacity Product Specifications Display 4 LS Light Sample AS Add Sample CQ Check Quantity CW Check Weight M In Accumulation Mode T Tare 0 Zero ...

Page 5: ...hange quantity and weight PCS SET Short press Used for counting function WT SET Short press Used to alternate counting P Short press Used as 1 Press for print function or 2 Press and hold to cancel upper and lower limit setting TAR Short press Used to reduce gross weight to tare weight ALARM Short press Set upper and lower limits for weight and quantity M Short press Add to memory for the alarm fu...

Page 6: ...cluded Installation Assemble the scale by installing the pan holder and weighing pan Attach the power cord and plug the scale into a 110V 220V socket Please confirm the correct voltage before using the scale 1 2 3 6 Getting Started Ensure the scale is level The supports on the bottom of the scale can be screwed in or out as needed to level the instrument Press the ON OFF button to turn the scale o...

Page 7: ...rence weights The instrument can only be as accurate as the standard masses used 1 2 3 4 5 6 NOTE If this is the first time using the balance repeat the calibration steps 2 3 times Please ensure that the scale is completely level and stable during calibration If after repeating the calibration steps 2 3 times the weighing is still inaccurate contact customer service for assistance before making a ...

Page 8: ...perating in one of these alarm states If it is try increasing the sample size or piece weight first before returning the product WT SET Enter the unit weight with the number keys and press WT SET When more units are added the counting window will show the total number of pieces The total weight window will display the total sample weight The unit weight window will display the weight of a single u...

Page 9: ...ch sample Once all samples have been weighed and removed press M and the entire weight and count will be displayed Press MC to clear all data 1 2 3 4 5 6 7 8 9 10 Accumulation Function Alarm Function Long press Alarm The display will show Weight If it does not press Zero to switch from weight to count function Press the Alarm key again to confirm the Weight function The screen will display hL Ther...

Page 10: ...ower limit using the number keys Press the Alarm key again to confirm upper and lower limit settings Reset settings by repeating steps 1 5 To cancel the setting Long press Alarm The display will show Count If it does not press ZERO to switch from Weight to the Count function Press the Alarm key again to confirm the selection The screen will display hL There will be one or two hyphens displayed to ...

Page 11: ...o confirm upper and lower limit settings Reset settings by repeating steps 1 5 To cancel the setting Settings Weight 1 2 3 4 5 6 7 a Press the Alarm key The screen will display lim hi Using the number keys press 0 b Press the Alarm key The screen will display lim lo Press 0 using the number keys Press the Alarm key to cancel the setting LP50 Print Mode Setting 1 Turn the scale on 2 Press 7 8 9 usi...

Page 12: ...button to send data to the PC Turn on the power Press the TARE button twice and press the CAL PCS key once When the LCD displays 01 dlU press the UNIT button until 08 bud is displayed Press the TARE button If 9600 is not displayed press the UNIT button until 9600 appears Press the TARE button 08 bud will appear Press the UNIT button 09 odE will appear Press TARE the number 3 will appear If 3 does ...

Page 13: ...up After selecting the desired baud rate e g 9600 press PRINT CAL to confirm Cleaning Always power off and unplug the scale before cleaning or storing it Use a damp cloth to wipe down the scale and weighing pan For stubborn stains use a mild detergent on a damp cloth Dry the scale after cleaning Do not clean the scale with solvents or cleaners that may cause damage or corrosion Do not immerse the ...

Page 14: ...d humidity Unstable power supply voltage Use a voltage stabilizer on the power supply Equipment in the vicinity producing high levels of electromagnetic interference or other forms of radiation Locate the balance away from such equipment or use shielding devices OVER is displayed Balance is overloaded Remove objects from the weighing pan No signal from the sensor Ensure the weighing pan is in cont...

Page 15: ... testing Testing is conducted until the readings are consistent and accurate Linearity A weight representing the maximum capacity of the balance is weighed 10 times until the margin of error for each weighing is less than the acceptable specified margin of error i e less than 03g for a 01g accuracy balance As an example for a 2000g maximum capacity balance a 2000g weight is used In order to pass t...

Page 16: ...ar products including analytical balances centrifuges glassware hematology counters hot plates magnetic stirrers pH meters pipettes and pressure pumps We stand behind all of our products offering 1 and 2 year warranties 30 day returns and a responsive customer service team committed to solving any questions or issues you may have About Us Website FristadenLab com Customer Support support fristaden...

Reviews: