Innovator CU10BT-CU5000BT Analog Transmitter
Initial On Site
Turn On Procedure
Instruction Manual, Rev. 0
24
Signal Name
Pin
Designations
Signal Type
Description
RMT Set to
Modulation Type
J12-6
Discrete Open Collector Input - A pull
down to ground on this line indicates
that the Modulation type is set to
Analog, or floating sets to Digital.
Command
RMT Set Channel
J12-7
Not Used
Command
RMT Ground
J12-8
Ground
RMT
System Forward
Power Level
J12-9
Analog Output - 0 to 4.0 V- This is a
buffered loop through of the calibrated
“System Forward Power”. Indicates the
System Forward power.
Scale factor is 100 % = 2.0V.
Metering
RMT
System Aural
Power Level
J12-10
Analog Output - 0 to 4.0 V- This is a
buffered loop through of the calibrated
“System Aural Power”. Indicates the
System Aural power. Scale factor is
100 % = 2.0V.
Metering
RMT
System Reflected
Power Level
J12-11
Analog Output - 0 to 4.0 V- This is a
buffered loop through of the calibrated
“System Reflected Power”. Indicates
the System Reflected power.
Scale factor is 25 % = 2.0V.
Metering
RMT
Input Status
J12-12
Discrete Open Collector Output - A low
indicates that the Input to the System is
OK. Floating indicates an Input Fault.
Status
RMT
Fault Status
J12-13
Discrete Open Collector Output - A low
indicates that the System is OK.
Floating indicates a Fault has occurred.
Status
RMT
Operate Status
J12-14
Discrete Open Collector Output - A low
indicates that the System is in Operate.
Floating indicates the System is in
Standby.
Status
RMT Ground
J12-15
Ground