Innovator CU10BT-CU5000BT Analog Transmitter
Initial On Site
Turn On Procedure
Instruction Manual, Rev. 0
20
Typical System Operating Parameters
Typical Operating Parameters for a CU10
Parameter
Typical Reading
Forward Power
100%
Reflected Power
<5%
Power Supply Voltage
+24 VDC
Heatsink Temperature
20º to 30º F/15º to 20º C above ambient temperature
Pin Attenuator Voltage
1 Volt to 5 Volts
Typical Operating Parameters for a CU50
Parameter
Typical Reading
Forward Power
100%
Reflected Power
<5%
Power Supply Voltage
+28 VDC
Heatsink Temperature
20º to 30º F/15º to 20º C above ambient temperature
Pin Attenuator Voltage
1 Volt to 5 Volts
Typical Operating Parameters for a CU100
Parameter
Typical Reading
Forward Power
100%
Reflected Power
<5%
Power Supply Voltage
+30 VDC
Heatsink Temperature
20º to 30º F/15º to 20º C above ambient temperature
Pin Attenuator Voltage
1 Volt to 5 Volts
Typical Operating Parameters for a CU200
Parameter
Typical Reading
Forward Power
100%
Reflected Power
<5%
Power Supply Voltage
+40 VDC
Heatsink Temperature
20º to 30º F/15º to 20º C above ambient temperature
Pin Attenuator Voltage
1 Volt to 5 Volts
Typical Operating Parameters for a CU100 used as a Driver
Parameter
Typical Reading
Forward Power
20-70% (Depending on output power level of system)
Reflected Power
<3%
Power Supply Voltage
+30 VDC
Heatsink Temperature
20º to 30º F/15º to 20º C above ambient temperature
Pin Attenuator Voltage
1 Volt to 5 Volts
Typical Operating Parameters for the external Amplifier Drawer(s)
in a CU500 or higher power System
Parameter
Typical Reading
Forward Power
100%
Reflected Power
<5%
Power Supply Voltage
+42 VDC
Heatsink Temperature
20º to 30º F/15º to 20º C above ambient temperature