background image

EN

67

EN

66

G - TECHNICAL AND LEGAL INFORMATION

1. COMPATIBLE ACCESSORIES

Backup battery

Photocells

Additional remote 

controls

Gate video 

intercom 

system

Coded keypad

Solar kit

2. TECHNICAL CHARACTERISTICS

The technical characteristics are provided as an indication only and for a temperature of +20°C. The avidsen 
company reserves the right to modify these characteristics at any time, while under all circumstances 
guaranteeing these products’ smooth operation and the type of use intended, with a view to improving 
these products.

MOTOR DRIVE

Type

24 VDC motors, reduction gear, override system

Contents

1 left motor and 1 right motor with integrated electronics

Power supply

24 VDC

Rated torque

50Nm

Summary of Contents for ORANE-CONNECT

Page 1: ...2 www avidsen com V2 FONCTIONNE AVEC AVIDSEN HOME CONNECTE 24V L 2 50M PAR BATTANT 250KG PAR BATTANT KG COMPATIBLE AVEC TOUS TYPES DE PORTAILS PORTAIL BATTANT YEARS 3 SMART 24V 2 50M PER PANEL 250KG P...

Page 2: ...ssembling the pivoting arm 13 3 3 Installing the motors for opening towards the inside of the property 14 3 4 Installing the motors for opening towards the outside of the property 20 4 INSTALLING THE...

Page 3: ...Connecting the contactor 51 8 USE VIA THE APP 52 9 USING THE PRODUCT WITH GOOGLE HOME 53 9 1 If you have an Android smartphone with Google assistant 54 10 USING THE PRODUCT WITH AMAZON ALEXA 54 11 SCE...

Page 4: ...e of the device may set the gate into motion Before setting the gate into motion ensure that there is no person in the area in which the gate moves Avoid any natural obstacles branch stone high grass...

Page 5: ...bstances to clean the product Do not clean the product with a pressure washer Use a lightly damp soft cloth Do not use aerosol sprays on the product because they could damage its interior Regularly ch...

Page 6: ...2 Secondary motor 3 Remote control 4 Flashing light and screws 5 Rear arm 6 Front arm 7 Post mounting bracket 8 Gate mounting bracket 9 M12 L40 screw 10 M8 L25 screw 11 M10 L90 screw 12 M8 CHC L30 sc...

Page 7: ...r Flashing light 10m cable 4 x 6 10 8m cable 2 x 1 5mm2 3m cable 2 x 0 5mm2 Attaching the brackets on the gate Choose a screw nut system that is suitable for the thickness of the gate There are 4 atta...

Page 8: ...c closing The flashing light is an essential safety component The photocell type safety devices and their correct operation must be checked every six months 1 2 Specifications of the gate to motorise...

Page 9: ...Following installation there may be a shear zone between the panel and the corner of the post In this case it is recommended to remove this zone leaving a minimum working distance of 25mm either by po...

Page 10: ...be confinement areas between the panels in open position and the fixed parts close to them To remove these areas it is mandatory to leave a safe distance of 500mm between the fixed part and the movin...

Page 11: ...the General warnings Before starting installation ensure that Hazards can be minimised by following the recommendations under the Chapter Hazard analysis The desired use has been correctly defined Th...

Page 12: ...3 Secondary motor 2 x 1 5mm cable 10m 4 Reception photocell RX 4 x 6 10 cable 10m 5 Transmission photocell TX 4 x 6 10 cable 10m 3 1 Installing the stops This gate motor drive is a self locking motor...

Page 13: ...0 135 50 central stop Inner side of the property view from above opening angle opening angle stop view D D 3 1 2 For opening towards the outside of the property D D central stop Inner side of the pro...

Page 14: ...ends of the pivoting arms will be fastened 1m maximum recommended 14mm Use plugs and screws that are suitable for the post material example for concrete use 12mm plugs and 8mm lag screws with a lengt...

Page 15: ...For optimum motor operation the distance X must be as small as possible Also remember that a 25mm safety distance is required between the open gate and the motor see Hazard analysis chapter Temporari...

Page 16: ...EN 16 12mm bit for 12 plugs Open the cover of the motors Fasten the motors on the mounting brackets C INSTALLATION...

Page 17: ...EN 17 Screw 11 Washer 18 Spring washer 17 Nut 16 Assemble the pivoting arms and motors Washer 12 Washer 14 Screw 10 C INSTALLATION...

Page 18: ...essing it firmly against the central stop Position the pivoting arms against the gate at a distance of 75cm and mark the location of the holes on the gate Important The ends of the right arms should b...

Page 19: ...e gate material Reassemble the end of the arm and the gate bracket Important At this point in the installation the motors are disengaged The gate may be set in motion by the wind or an external push B...

Page 20: ...g arms will be fastened 1m maximum recommended 14mm Inner side of the property Use plugs and screws that are suitable for the post material example for concrete use 12mm plugs and 8mm lag screws with...

Page 21: ...EN 21 C INSTALLATION 37 mm 115mm 12 mm 12mm bit for 12 plugs Open the cover of the motors...

Page 22: ...EN 22 Fasten the motors on the mounting brackets Screw 12 Nut 16 Assemble the pivoting arms and motors Washer 14 Washer 20 Screw 13 C INSTALLATION...

Page 23: ...up to the side stops Turn the pivoting arm to press the gate bracket against the gate as far as possible from the hinges Mark the holes for fastening the bracket on the gate Important The ends of the...

Page 24: ...suitable for the gate material Reassemble the end of the arm and the gate bracket Important At this point in the installation the motors are disengaged The gate may be set in motion by the wind or an...

Page 25: ...remove the transparent part of the flashing light by unscrewing the 2 screws that hold the upper part of the flashing light Continuing to use a screwdriver remove the flashing light bracket by unscrew...

Page 26: ...properly align the infrared beam of the photocells Place the photocells at exactly the same height from the ground they must be perfectly aligned and parallel to each other The distance between the o...

Page 27: ...RX indicated on the back on the motor post containing the electronic card The surface of the posts must be perfectly flat in order to properly align the infrared beam of the photocells Place the photo...

Page 28: ...and parallel to each other The reception photocells RX indicated on the back must be installed facing the motor post where the electronic card is located see drawing below Additional photocells must...

Page 29: ...NSTALLATION 30cm mini 60cm maxi RX1 RX1 pair 1 pair 1 pair 2 pair 2 10 cm min 15 cm max 10 cm min 15 cm max TX1 TX1 90 90 90 90 RX2 RX2 TX2 TX2 Opening inwards view from above Opening outwards view fr...

Page 30: ...connections must be performed with the power switched off safety switch in OFF position and the battery disconnected These connections must be made by a qualified electrician 6 1 The mains electricit...

Page 31: ...opens first must be connected to the M1 output of the electronic card Black Red For outward opening with the motor mounted on the left post view from inside OR For inward opening with the motor mounte...

Page 32: ...th one set of photocells remove the connector between GND and PHO photocell RX1 photocell TX1 BAT TRANS GND GND PHO 24V M1 M2 M1 M2 warn warn 2B NO COM NC With 2 sets of photocells remove the connecto...

Page 33: ...state feedback from the application Put the gate in closed position Install the pre wired magnet on the panel on the side of the electronic card Install the passive magnet on the other panel leaving a...

Page 34: ...rking It is possible to connect a backup battery to perform some manoeuvres in the event of power failure Type of battery NiMH Battery voltage 24V Configuration 20xAAA 800mAh Use the connection cable...

Page 35: ...kit is plugged into the same connector as the backup battery The solar power kit which already has a battery and a backup battery cannot be connected at the same time For installation refer to the sol...

Page 36: ...play press PROG 2 or 3 times and only the green LED should be switched on When the user performs no action on a button for 15 seconds the system automatically goes back to MENU 0 2 BASIC SETTINGS MENU...

Page 37: ...nue le temps OK MENU 0 r glable de 0 4 MODE 1 pas de fermeture auto MODE 2 fermeture auto MODE 3 mode collectif force des moteurs mode de fonctionnement temps de temporisation 0 15 sec 1 30 sec par de...

Page 38: ...strian command Collective mode mode 3 This mode is used for a collective access gate Closed gate one press on the gate command opens the gate which remains open for a certain time adjustable time see...

Page 39: ...the and buttons to change the force and confirm with the OK button All the LEDs will switch on and off to confirm the operation NOTE if the force setting is changed self learning must be repeated 2 6...

Page 40: ...ning If self learning does not work as described above and stops earlier than expected the motors and the flashing light stop some of the red LEDs will be on or flashing and others will be off The con...

Page 41: ...s the gate command and which button will be used as the pedestrian command 2 8 1 Programming with the card Note It is possible to programme a remote control once then use the copy function that allows...

Page 42: ...leting all remote controls To unprogramme all the remote control buttons learnt follow the procedure below Press for 3 seconds and L1 will switch on Press twice and L1 will turn off and L3 will turn o...

Page 43: ...but d ouverture par d faut 1 actives en d but d ouverture 0 portail 2 battants par d faut 1 portail 1 battant portillon L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3...

Page 44: ...on To activate or deactivate this function follow the procedure below Press PROG for 3 seconds L0 will flash once and L1 will switch on Press PROG for 3 seconds L0 will flash twice Press twice and L3...

Page 45: ...one gate panel closes over the other This panel is controlled by the motor connected to output M1 of the electronic card To ensure that the panels close in the correct order the system arranges for th...

Page 46: ...this time to 3 seconds To set the pre flashing time follow the procedure below Press PROG for 3 seconds L0 will flash once and L1 will switch on Press PROG for 3 seconds L0 will flash twice Press PRO...

Page 47: ...from playing near or with the motorised gate Do not deliberately stop the moving gate except of course with a control device or for an emergency stop Prevent any natural obstacles branches stones high...

Page 48: ...l resume its normal pace 1 flash per second 1 second later panel M2 starts closing A few seconds later panel M1 starts closing Panel M2 reaches its closing stop Some time later 2 5 seconds by default...

Page 49: ...in the opposite direction If an obstacle is detected during closure and the operating mode is automatic closure or collective the gate will open again and the time delay will start again If the gate...

Page 50: ...wnload the Avidsen Home app from the Android Play Store or Apple App Store Launch the app and log in if you already have an account If not press CREATE A NEW ACCOUNT and let the application guide you...

Page 51: ...on Select the product you wish to pair and select Home Gate Make sure the contactor is connected and its indicator light is flashing If not press and hold the reset button for 5s so that the indicator...

Page 52: ...on e g obstacle detection motor error etc if the gate remains ajar the contactor cannot be held responsible IMPORTANT The dry contact signal is the same whether the opening or closing of the gate is t...

Page 53: ...THE PRODUCT WITH GOOGLE HOME NOTE the name you give your Avidsen Home devices is the one that will be recognised by Google Assistant Example if you have a contactor named gate OK Google open gate will...

Page 54: ...thing The following information may vary depending on updates to the Alexa app or your operating system The Amazon Alexa Assistant can help you control your connected devices For example you can use t...

Page 55: ...ENARIO AND AUTOMATION 11 1 Scenario The scenario system in the Avidsen Home app allows you to group actions that will be triggered on demand by clicking on a single button on your smartphone Example c...

Page 56: ...creating a Gate opening automatic action that triggers a contact at a given time only if the gate is in closed position The automation system in the Avidsen Home app allows you to group devices and a...

Page 57: ...esponds to a OU OR function If Temperature x OU OR time y OU OR device n then After selecting the condition type choose the conditions themselves 1 3 5 7 2 4 6 1 Set a temperature weather condition 2...

Page 58: ...a device already recorded in the app The last setting allows you to define a time slot during the day if necessary during which to authorise the automation launch Once all these settings have been co...

Page 59: ...olumn in the minute column The time configured will appear between the two parallel lines You can ask for a repeat of the scenario on different days of the week To configure this click on Repeat The c...

Page 60: ...e your scenario at your convenience in our example GATE OPENING Once all parameters have been set click on Save If you wish to access the details or delete it click on the icon at the top right of its...

Page 61: ...EN 61 E USE...

Page 62: ...The water inputs the product is intended for outdoor use however incorrect positioning of the lid the holes made to run the cable or an incorrectly positioned grommet can damage the product Any trace...

Page 63: ...ional and the history of events OK Charge batterie PROG OK Code 1 PROG Code 2 Code 3 Code 4 OK 3s efface historique du plus r cent au plus ancien MENU 0 derni re erreur L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L...

Page 64: ...imum operating time has been reached a motor is idle and the stop has not been reached Check that the motor is engaged E Panel M1 closed before panel M2 Increase the time interval between the movement...

Page 65: ...n if the infrared beam is unobstructed If a wired control device is connected to input 2B LED L2 turns on when the contactor of the component is activated 2 3 Total reset You can reset to factory sett...

Page 66: ...EN 66 F MAINTENANCE AND UPKEEP 2 5 Replacing the power fuse Switch the motor drive off Use a 250V 5A time delay fuse...

Page 67: ...n indication only and for a temperature of 20 C The avidsen company reserves the right to modify these characteristics at any time while under all circumstances guaranteeing these products smooth oper...

Page 68: ...ion 16 bit Rolling code encoder i e 65 536 possible combinations Frequency 433 92 MHz Open air range 80 m Power supply CR2032 Touch sensitive 4 keys Radiated power 10 mW Battery life 1 year at a rate...

Page 69: ...s Connection Wired 1 output Cable cross section Up to 1 5mm2 Use Indoors and outdoors Operating temperature 10 C 50 C Storage temperature 20 C 70 C Power supply 230 VAC 50 Hz Average consumption 1W Po...

Page 70: ...lso hazardous to your health and are explosive Do not use any tool that can conduct voltage wire brush sharp tool etc for cleaning The receipt or invoice is proof of purchase date 4 ASSISTANCE AND ADV...

Page 71: ...essed pursuant to the applicable standards in force Directive RED 2014 53 EU EN 300220 1 V3 1 1 EN 300220 2 V3 2 1 Directive LVD 2014 35 EU EN 62479 2010 EN 62368 1 2014 A11 2017 Directive EMC 2014 30...

Page 72: ...Avidsen 19 avenue Marcel Dassault ZAC des Deux Lions 37200 Tours France...