![Avidsen ORANE-CONNECT Manual Download Page 12](http://html1.mh-extra.com/html/avidsen/orane-connect/orane-connect_manual_3031447012.webp)
EN
13
EN
12
C - INSTALLATION
Tip:
Position the motor containing the electronic card on the post where the 230V electrical supply is located.
If the 230V electrical supply is already located on the left post, the connections do not need to be reversed.
If the electrical supply is located on the right post, it is sufficient to reverse the motor connection polarity in
order to reverse the direction of rotation with respect to the assembly described in these instructions (normal
mounting with motor and electronic card on the left).
List of cables:
Connection
Cable
Max length
1
230VAC power line
Cable 3 x 2.5mm
2
(more than 30m long)
Cable 3 x 1.5mm
2
(less than 30m long)
Unlimited
2
Flashing light
Cable 2 x 0.5mm
2
15m
3
Secondary motor
2 x 1.5mm² cable
10m
4
Reception photocell (RX)
4 x 6/10 cable
10m
5
Transmission photocell (TX)
4 x 6/10 cable
10m
3.1. Installing the stops
This gate motor drive is a self-locking motorisation system. Your 2-panel gate must be equipped with a central
stop and side stops (not included).
The (central and side) stops must stop the gate without locking it. In other words, any mechanical lock (or
latch) and any tilting shoe base or stopper must be removed.
3.1.1. - For opening towards the inside of the property
The installation of the side stops depends on the desired opening angle which depends on distance D (the
distance between the axis of the hinge and the inner side of the post).
D
D
D
D
Positive distance D
Negative distance D
view from above
view from above
post
post
If positive distance
D
is greater than 200 mm or if distance D is negative, the configuration of the posts must
be adjusted.