2.2. Photocell alignment procedure (optional)
The electronic card of this motorised gate is on
standby after 1 minute with no action.
On standby, the photocells no longer have power.
• To prolong the “activation” time, press and release
one of the buttons.
When the photocells have power, a red indicator is
lit inside each one.
When the photocells are not aligned, a second
indicator light turns on in the RX photocells.
When the photocells are aligned, only one red indicator
light turns on inside the RX photocell.
• Move your hand in front of it to hide the infrared
beam. The second indicator light turns on and
off. A relay click can be heard when the status
changes.
2.3. Operating mode
This automatic gate opening mechanism has 3
operating modes.
Semi-automatic mode (mode 1) (default)
• Closed gate -> to open the gate, press and
release the gate command.
• Open gate -> to close the gate, press and release
the gate command.
While the gate is in motion, you can stop it by
pressing the (gate or pedestrian) command.
By pressing on the gate command again, the gate
swings in the opposite direction.
Automatic closing mode (mode 2)
• Closed gate: one press on the gate command
opens the gate, which remains open for a certain
time (adjustable time, see “Time delay”), then
closes automatically.
• During the time delay, you can cancel the automatic
closure by pressing the (gate or pedestrian)
command. The gate stays open and you must press
the gate command to close the gate.
While the gate is in motion, you can stop it by
pressing the (gate or pedestrian) command.
Collective mode (mode 3)
This mode is used for a collective access gate.
• Closed gate: one press on the gate command
opens the gate, which remains open for a certain
time (adjustable time, see “Time delay”), then
closes automatically.
Unlike the automatic closure mode:
• If you press a command during opening, it will not
be acknowledged.
• If you press a command during the time delay,
instead of cancelling the automatic closure, the
time delay starts again at 0.
• If you press a command during closure, the gate
stops, opens back up and starts the automatic
closure time delay.
• You can only control the complete gate. The
pedestrian command does not work.
To choose the operating mode, set a value
from 1 to 3. Follow the procedure below
• Press
PROG
for 3 seconds. L0 will flash once
and L1 will switch on.
• Press
OK
and the number of red LEDs that turn
on will indicate the operating mode that has
already been set (mode 1 by default).
• To change the operating mode, use the “
–
” and
“
+
” buttons, then confirm with the
OK
button. All
the LEDs turn on and off to confirm the operation.
N.B.: applicable regulations require the
installation of photocells for safety during
automatic closing.
2.4. Time delay
The time delay is the time during which the gate
remains open before closing automatically (if
automatic closing is activated).
To adjust this value, follow the procedure
below
• Press
PROG
for 3 seconds. L0 will flash once
and L1 will switch on.
• Press “
+
” once. L2 will turn on instead of L1.
• Press OK, and the number of red LEDs that turn
on will indicate the set value.
• Use the “
+
” and “
-
” buttons to change this value
(see table below).
• Press OK to confirm this value. All the LEDs will
turn on and off to confirm the operation.