48
E - USE
• If this is not the case and the beam is obstructed
when the gate should start to open, the flashing
light will emit double flashes for 30 seconds
unless a command is activated. For the gate to
be able to open, the beam must be unobstructed
and a command must be activated.
5.1. Obstacle detection
During their movement, the panels may encounter
an obstacle.
• For safety purposes, if the motors are under too
much strain (the force is adjustable; see “Motor
Force” in the settings), the gate stops and
releases the pressure and the flashing light emits
double flashes for 30 seconds unless a command
is activated.
• On activating a command (the same one that was
used to start the movement), the gate starts to
move in the opposite direction.
• If an obstacle is detected during closure and
the operating mode is “automatic closure” or
“collective", the gate will open again and the time
delay will start again.
• If the gate has a large area of wind resistance
(solid gate), this can trigger obstacle detection in
windy weather. In this case, increasing the motor
force is recommended.
6. MANUAL MOVEMENT
To manually operate the gate, simply disengage
each motor using the key provided (part 21). Insert
the key into the override system under the engine
and turn counterclockwise (view from below). Refer
to the instructions on the motor next to the override
system.
To engage, perform the opposite operation (turn
clockwise), then move each panel until it locks.
WARNING:
When the motors are disengaged, the gate
may be set in motion by the wind or an external
push. It is therefore important to be careful or
block the gate to avoid any risk of injury.