SAFETY
Make sure that there is no one in the gate movement
area during the entire commissioning period and the
entire test period.
Starting self-learning
• Check that you are not in a prog menu by pressing
on prog 3 consecutive times.
• Press and hold the “
+
” button for 3 seconds.
The self-learning procedure may be interrupted at
any time by pressing OK.
Self-learning procedure
• The flashing light flashes.
•
Phase 0
: repositioning in central stop
Panel M2 closes up to the central stop.
Panel M1 closes up to the central stop.
•
Phase 1
: detection of side stops
Panel M1 opens up to the side stop.
Panel M2 opens up to the side stop.
•
Phase 2
: path detection
Panel M2 closes again up to the central stop
Panel M1 closes again up to the central stop.
•
Phase 3
: learning opening and closing
Panel M1 starts to open, gradually accelerating.
Panel M2 starts to open, gradually accelerating,
2.5 seconds (or more depending on the setting,
see MENU 3) after M1.
The panels reach their opening stops.
Panel M2 starts to close, gradually accelerating.
Panel M1 starts to close, gradually accelerating.
The panels reach the central stop (with a
difference of 2.5 seconds or more depending on
the setting, see MENU 3)
Error during self-learning
If self-learning does not work as described above
and stops earlier than expected (the motors and the
flashing light stop), some of the red LEDs will be on
or flashing, and others will be off. The configuration
of the red LEDs that are on provides an error code
allowing the installer to determine the source of the
incident that has occurred.
Below is a table indicating the self-learning error
codes:
: LED off
: LED on
: Flashing LED light
Make sure not to confuse the self-learning
error codes with error codes of events that
may occur during normal operation and which
are indicated in the same way by a combination
of red LEDs that are on / off / flashing.
(See page 47)
L1
L2
L3
L4
Description
In phase 0, panel M1
did not arrive at a stop
after closing for 60s,
disengagement or cable
section too weak?
In phase 0, panel M2
did not arrive at a stop
after closing for 60s,
disengagement or cable
section too weak?
In phase 0, motor M1
was not detected (not /
incorrectly connected?).
In phase 0, motor M2
was not detected (not /
incorrectly connected?).
In phase 1, motor M1
reached the stop after
opening for less than 3s:
reduce the speed.
In phase 1, motor M2
reached the stop after
opening for less than 3s:
reduce the speed.
In phase 1, panel M1 did
not reach a stop after
opening for 60s or cable
section too weak?
In phase 1, panel M2 did
not reach a stop after
opening for 60s or cable
section too weak?
D - BEGINNING OPERATION