EN
29
D - BEGINNING OPERATION
2.4.3 - DELETING ALL REMOTE CONTROLS
To deprogram all the remote control buttons
learnt, follow the procedure below
•
Press “–” for 3 seconds and L1 will switch on.
•
Press “+” twice and L1 will turn off and L3 will turn
on.
•
Press
SET
and the 5 red LEDs will switch on.
•
Press
SET
for 3 seconds and all the LEDs will
switch off and switch on to confirm the operation.
2.5 - MOTOR FORCE
This system controls the force of the motor by
limiting the maximum power it can absorb. In most
cases, it is not necessary to change this setting.
The force is adjustable from 0 to 5 and is set to 3
by default.
However, if the gate is very heavy, or there is too
much friction due to the guide rails, the force may
be insufficient.
In this case, it is necessary to increase the level of
force. After having completed the self-learning and
programmed a button on the remote control, initiate
the gate to open completely, to see if it opens fully,
without appearing to struggle.
If it is struggling, increase the force.
Note:
To meet the requirements of Standard EN 12453,
it may be necessary to change the force of the
motors.
To adjust the force, follow the procedure below
•
Press “
PROG
” for 3 seconds. L0 will flash once
and L1 will switch on.
•
Press “+” twice and L3 will switch on instead of
L1.
•
Press
“SET”
, and the number of LEDs lit will then
show the value of the force set.
•
Use the “+” and “-” buttons to change the force
and confirm with the
SET
button. All the LEDs will
switch on and off to confirm the operation.
NOTE: if the force setting is changed, self-
learning must be repeated.
2.6 - OPERATING MODE
This automatic gate opening mechanism has 3
operating modes.
Semi-automatic mode (mode 1) (default)
•
Closed gate -> to open the gate, press and
release the gate command.
•
Open gate -> to close the gate, press and release
the gate command.
While the gate is in motion, you can stop it by
pressing a command (complete or partial).
By pressing on the gate command again, the gate
swings in the opposite direction.
Automatic closing mode (mode 2)
•
Closed gate: one press on the command
(complete or partial) opens the gate, which
remains open for a certain time (adjustable time,
see “Time delay”), then closes automatically.
During the time delay, you can cancel the automatic
closure by pressing a command (complete or
partial). The gate stays open and you must press
the gate command to close the gate.
While the gate is in motion, you can stop it by
pressing a command (complete or partial).
By pressing on a command again, the gate starts in
the opposite direction.
Collective mode (mode 3)
This mode is used for a collective access gate.
•
Closed gate -> one press on the gate command
opens the gate, which remains open for a certain
time (adjustable time, see “Time delay”), then
closes automatically.
Unlike the automatic closure mode:
•
If you press a command during opening, it will not
be acknowledged.
•
If you press a command during the time delay,
instead of cancelling the automatic closure, the
time delay starts again at 0.
•
If you press a command during closure, the gate
stops, opens back up and starts the automatic
closure time delay.
You can only control the complete opening. The
partial command does not work.
CONNECTED MOTOR DRIVE KIT