EN
27
D - BEGINNING OPERATION
2.2 - PHOTOCELL ALIGNMENT PROCEDURE
The electronic card of this motorised gate is on
standby after 1 minute with no action. On standby,
the photocells no longer have power.
•
To prolong the “activation” time, press and release
one of the buttons.
When the photocells have power, a red indicator is
lit inside each one.
When the photocells are not aligned, a second
indicator light turns on in the RX photocells. When
the photocells are aligned, only one red indicator
light turns on inside the RX photocell.
•
Move your hand in front of it to hide the infrared
beam. The second indicator light turns on and
off. A relay click can be heard when the status
changes.
2.3 - SELF-LEARNING
The role of self-learning:
In order for the card to learn which motors are
connected and the path of the door, self-learning
must be launched.
In addition, if certain settings are changed (force,
obstacle reaction time), self-learning must be
repeated.
IMPORTANT:
• Before starting the self-learning procedure,
you can check that the gate opens in the
correct direction (manual control)
• Press SET for 3 seconds and then,
• Press and hold “+” › the gate should open ›
release the button.
• Press and hold “–” › the gate should close ›
release the button.
If the gate opens instead of closing, the motor
is connected backwards.
• Disconnect the power supply and fix
the problem (see “motor polarity” in the
“connections” chapter).
• If the gate opens in the correct direction ›
press PROG to exit manual control.
SAFETY
Make sure that there is no one in the gate movement
area during the entire commissioning period and the
entire test period.
Starting self-learning
•
Press “+” for 3 seconds. The self-learning
procedure may be interrupted at any time by
pressing
SET
.
Self-learning procedure
•
The flashing light starts (1 flash per
second).
• Phase 0:
detection of closing stop
The gate closes up to the closing stop.
• Phase
1:
measurement of opening length
The gate opens up to the opening stop.
• Phase
2:
measurement of closing length
The gate closes up to the closing stop.
Error during self-learning
If self-learning does not work as described above
and stops earlier than expected (the motors and the
flashing light stop), some of the red LEDs will be on,
and others will be off. The configuration of the red
LEDs that are on provides an error code allowing
the installer to determine the source of the incident
that has occurred.
Below is a table indicating the self-learning error
codes:
/
/
/
/
/
/
/
/
/
/
/
/
/
: LED
off
/
/
/
/
/
/
/
/
/
/
/
/
/
: LED
on
Make sure not to confuse the self-learning error
codes with events that may occur during normal
operation and which are indicated in the same way
by a combination of red LEDs that are on/off.
L1
L2
L3
L4 L5
Meaning
All LEDs are
off,
self-learning
was successful.
The motor is not
connected to the
electronic card.
The motor has run
for 60 seconds on
opening without the
gate finding a stop;
this is not normal.
CONNECTED MOTOR DRIVE KIT