![Avenview MLT-PROWALL-4K User Manual Download Page 21](http://html1.mh-extra.com/html/avenview/mlt-prowall-4k/mlt-prowall-4k_user-manual_3029197021.webp)
5.5.3 Example three
* Mode 06A – 1x3 (Ratio 1.69)
(Please apply portrait image content to get normal viewing angle. If the content is not at portrait position, then
user needs to use MLT-PROWALL-4K to rotate the content. )
5.6 Signal source output resolution selection
Video signal resolution setting will affect final video quality. Please follow below recommendation to set
signal source output resolution.
5.6.1 Basic concept for video source output resolution settings
d.
Horizontal direction: If only single unit is required in horizontal direction, please set the horizontal output
resolution at 1920. If multiple units of MLT-PROWALL-4K are required in horizontal cascade direction, then
please set the horizontal output resolution at 3840.
e.
Vertical direction: If only single unit is required in vertical direction, please set the vertical output resolution
at 1080. If multiple units of MLT-PROWALL-4K are required in vertical cascade direction, please set the
vertical output resolution at 2160.
5.6.2 Example for input resolution settings:
a.
When using single MLT-PROWALL-4K, please apply 1920x1080 @60Hz input resolution.
b.
For dual MLT-PROWALL-4K horizontal cascade, please set 3840x1080 @60Hz as input resolution.
c.
For dual MLT-PROWALL-4K vertical cascade, please set 1920x2160 @60Hz as input resolution
d.
For 2x2 four MLT-PROWALL-4K cascades, 3840x2160 @30Hz input resolution will get the best video quality.
e.
For more complicated cascade, please follow the instruction in section 9.
5.6.3 How to set input timing resolution:
a.
Please change the input resolution by [EDID] setting in page 49 or to change output resolution and select
correct aspect/scaling setting in PC output resolution setting.
b.
If the output resolution is not standard VESA standard timing, user needs to set the output resolution from
display card custom output timing setting.
5.6.4 Please confirm the setting result by [INFO] menu from IR remote controller.
Mode 06A means DIP SW pin #6 shall be set to “ON” position.
“A” means this mode is only be achieved by rotating the image from
signal source. If the image is not rotated from signal source, then it is
necessary to rotate the image by MLT-PROWALL-4K through IR remote
controller. Please pay attention to content aspect ratio.
MLT-PROWALL-4K output connection
1.1 MLT-PROWALL-4K TV1 output is connected to #1 LCD
1.2 MLT-PROWALL-4K TV2 output is connected to #2 LCD
1.3 MLT-PROWALL-4K TV3 output is connected to #3 LCD
1.4
MLT-PROWALL-4K TV4 will show full screen image same as signal source. It can
be connected to other LCD or monitor for system monitoring.