Aventics HF02 Operating Instructions Manual Download Page 78

Configuration

78

AVENTICS

 | INTERBUS | R412005655–BDL–001–AB

S1/8 switch baud rate

The baud rate (data transfer speed) can be set to either 

500 kBaud or to 2 MBaud.

The baud rate setting on the S1/8 switch must be identical 

to the data transfer speed set by the master. If there is a 

deviation, the entire bus cannot be operated!

Once the S1/1, S1/6 and S1/8 switches have been altered, 

it is important to reconfigure the bus as these switch 

positions affect the entire bus system.

S1/2 to S1/6 switches

diagnostic settings

See Fig. 2

NOTICE

The SMD switches can only be adjusted when the power 

supply is switched off, i. e. in a voltage-free state!

Table 8:

Diagnostic settings, SMD S1 switch assignment

Switch/Function

Effect

S1/2

Overload of valves, 
outputs/module, 
inputs/module

ON

Collective message (PF) on

OFF

Collective message (PF) off

S1/3

US1
Low voltage/
bus terminal overload

ON

Collective message (PF) on

OFF

Collective message (PF) off

S1/4

US2
Low voltage/Faulty fuse

ON

Collective message (PF) on

OFF

Collective message (PF) off

S1/5

US2
Emergency off

ON

Message on

1)

1)

Emergency off is only reported after approx. 200 ms.

OFF

Message off

S1/6

Single bit diagnosis

ON

Switched on

OFF

Switched off

Summary of Contents for HF02

Page 1: ...ns R412005655 10 2014 Replaces 08 2004 DE EN Ventilsystem HF03 HF02 und Buskoppler CMS L Design mit Lichtwellenleiter und Diagnose Valve system HF03 HF02 and bus coupler CMS L Design with Fiber Optics and Diagnosis INTERBUS Deutsch English ...

Page 2: ......

Page 3: ...abhängige Sicherheitshinweise 11 3 Systemübersicht 12 3 1 Aufbau 13 3 1 1 Buskoppler 13 3 1 2 Eingangsmodul 16 fach E24V 16f IB 14 3 1 3 Ausgangsmodul 8 fach A24V 0 5A IB 15 3 1 4 Power Modul PM12A 15 3 2 Strom und Spannungsversorgung 15 3 2 1 Buskoppler 15 3 2 2 Power Modul PM12A 17 3 3 Funktion 17 3 3 1 Buskoppler 17 3 3 2 E A Module 18 3 3 3 Power Modul PM12A 18 4 Konfiguration 19 4 1 Voreinste...

Page 4: ...uskoppler 39 6 3 2 Diagnoseanzeige am Eingangsmodul 16 fach E24V 16f IB 40 6 3 3 Diagnoseanzeige am Ausgangsmodul 8 fach A24V 0 5A IB 41 6 4 Diagnosemeldungen 41 6 4 1 Diagnosemeldungen zum Master 41 6 4 2 Spannungsdiagnose im Status Byte 43 6 4 3 Diagnose des Eingangsmoduls im Eingangsdatenbereich 46 6 4 4 Diagnose des Ausgangsmoduls im Eingangsdatenbereich 47 6 4 5 Beispiel 48 6 4 6 ID Kennungen...

Page 5: ...enthält wichtige Informationen um das Produkt sicher und sachgerecht zu montieren in Betrieb zu nehmen zu warten zu demontieren und einfache Störungen selbst zu beseitigen O Lesen Sie diese Dokumentation vollständig und insbesondere das Kapitel Sicherheitshinweise bevor Sie mit dem Produkt arbeiten 1 2 Erforderliche und ergänzende Dokumentationen O Nehmen Sie das Produkt erst in Betrieb wenn Ihnen...

Page 6: ...ingehalten werden Sicherheitshinweise sind wie folgt aufgebaut W Warnzeichen macht auf die Gefahr aufmerksam W Signalwort gibt die Schwere der Gefahr an W Art und Quelle der Gefahr benennt die Art und Quelle der Gefahr W Folgen beschreibt die Folgen bei Nichtbeachtung W Abwehr gibt an wie man die Gefahr umgehen kann SIGNALWORT Art und Quelle der Gefahr Folgen bei Nichtbeachtung O Maßnahme zur Gefa...

Page 7: ...rperverletzungen eintreten können wenn sie nicht vermieden wird ACHTUNG Sachschäden Das Produkt oder die Umgebung können beschädigt werden Tabelle 3 Bedeutung der Symbole Symbol Bedeutung Wenn diese Information nicht beachtet wird kann das Produkt nicht optimal genutzt bzw betrieben werden O einzelner unabhängiger Handlungsschritt 1 2 3 nummerierte Handlungsanweisung Die Ziffern geben an dass die ...

Page 8: ...s Produkt an Dritte stets zusammen mit den erforderlichen Dokumentationen weiter 2 2 Bestimmungsgemäße Verwendung Bei dem Produkt handelt es sich um eine elektropneumatische Anlagenkomponente Sie dürfen das Produkt wie folgt einsetzen W Setzen Sie den Buskoppler ausschließlich im industriellen Bereich ein Für den Einsatz im Wohnbereich Wohn Geschäfts und Gewerbebereich ist eine Einzelgenehmigung b...

Page 9: ...ht bestimmungsgemäßer Verwendung liegen allein beim Benutzer Als nicht bestimmungsgemäße Verwendung gilt wenn Sie das Produkt W außerhalb der Anwendungsgebiete verwenden die in dieser Anleitung genannt werden W unter Betriebsbedingungen verwenden die von den in dieser Anleitung beschriebenen abweichen W verändern oder umbauen 2 4 Qualifikation des Personals Die in dieser Dokumentation beschriebene...

Page 10: ...ehör und Ersatzteile um Personengefährdungen wegen nicht geeigneter Ersatzteile auszuschließen W Halten Sie die in der Produktdokumentation angegebenen technischen Daten und Umgebungsbedingungen ein W Wenn in sicherheitsrelevanten Anwendungen ungeeignete Produkte eingebaut oder verwendet werden können unbeabsichtigte Betriebszustände in der Anwendung auftreten die Personen und oder Sachschäden ver...

Page 11: ...spannungs und drucklos bevor Sie das Gerät montieren oder demontieren Sorgen Sie dafür dass die Anlage während der Montagearbeiten gegen Wiederanschalten gesichert ist W Erden Sie die Module und das Ventilsystem Beachten Sie die folgenden Normen bei der Installation des Systems DIN EN 50178 Klassifikation VDE 0160 VDE 0100 Bei der Inbetriebnahme W Die Installation darf nur in spannungsfreiem und d...

Page 12: ...eitert oder umgebaut werden Die Betriebsanleitung des Ventilsystems setzt sich aus einzelnen Komponenten zusammen Abb 1 Systemstruktur X72 OUT X72 OUT X71 IN X71 IN INTERBUS US1 US2 UL D RC BA RD LD US1 US2 UL D RC BA RD LD FO1 FO2 E IBDIA FO1 FO2 E IBDIA 015 S1 BTN Made in G ermany IB_DIA A24V 0 5A IB 015 1 827 030 179 1 827 030 179 Made in Germany Made in Germany 1 0 2 3 7 6 5 4 0 1 7 9 8 6 5 4 ...

Page 13: ...6 fach E24V 16f IB Ausgangsmodul 8 fach A24V 0 5A IB W Power Modul PM12A 3 1 1 Buskoppler BUS IN X71 und BUS OUT X72 Rugged Line Anschlüsse W LWL Anschluss für den Feldbus INTERBUS mit LWL zur Ansteuerung der Ventile und der Eingangs Ausgangsmodule W elektrischer Anschluss für die Spannungsversorgung für Ventilspulen und Ausgänge Logik und Eingänge Einstellelemente 8 fach SMD Schalter unter der PG...

Page 14: ...anzeige Beschriftungsfeld Unterhalb der jeweiligen Gerätedose Tabelle 5 LED Anzeige am Buskoppler INTERBUS für Versorgung und Fernbus LED Farbe Bedeutung US1 grün rot Logik und Eingangsversorgung US2 grün rot Ventil und Ausgangsversorgung UL D grün gelb Logikversorgung Sammeldiagnose RC grün Bus angeschlossen BA grün Datenaustausch RD gelb Fernbus abgeschaltet LD gelb Lokalbus abgeschaltet Tabelle...

Page 15: ...nzeige 1 LED grün für die Stromversorgung 3 2 Strom und Spannungsversorgung 3 2 1 Buskoppler Versorgung über Rugged Line Verbindung Über die Rugged Line Verbindung werden dem Ventilsystem die beiden Versorgungsspannungen US1 und US2 zugeführt ACHTUNG Falsche Polung Die beiden Spannungen US1 und US2 sind nicht galvanisch voneinander getrennt Die GND Verbindung beider Spannungen ist intern gebrückt ...

Page 16: ...A W für Ventilversorgung P24VV 2 3 A W für Ausgangsversorgung P24VA 6 0 A Verpolungsschutz Die Versorgungsspannungen L24V P24V und P24VV sind mittels Dioden gegen Verpolung geschützt Sicherung Die Versorgungsspannung P24VA für die Ausgänge ist über eine Schmelzsicherung abgesichert deren Defekt über das Blinken der LED US2 signalisiert wird US1 und US2 Unterspannungs überwachung 18 5 V Die Versorg...

Page 17: ...BUS entspricht der Norm DIN EN 19258 für den INTERBUS Einzelheiten entnehmen Sie bitte dieser Norm bzw der entsprechenden Literatur und der Betriebsanleitung des Busmasters Busklemme Der Buskoppler ist mit der Busklemmenbeschaltung für den Lichtwellenleiteranschluss Typ Rugged Line von Phoenix Contact ausgestattet VORSICHT Bei vorhandenem Power Modul besteht eine interne Verbindung des PGND Pin an...

Page 18: ...inem Ventilsystem eingesetzt werden Belastbarkeitsgrenzen einhalten Eingangsmodule am Buskoppler Der Buskoppler versorgt sämtliche Sensoreingänge der Eingangsmodule bis zu einem maximalen Summenstrom von 2 A die am Ventilsystem angeschlossen sind Ausgangsmodule am Buskoppler Der Buskoppler versorgt nur diejenigen Ausgänge der Ausgangsmodule bis zu einem maximalen Summenstrom von 6 A die am Buskopp...

Page 19: ...gen und die Einstellungen der Diagnosemeldungen zugänglich Alle Schalter befinden sich bei der Auslieferung in der OFF Position Die neue Einstellung wird erst beim Einschalten des Buskopplers übernommen Nach dem Ändern der Schalter S1 1 S1 6 und S1 8 ist der Busaufbau neu zu konfigurieren da sich diese Schalterstellungen auf das gesamte Bussystem auswirken Abb 2 SMD Schalter S1 des Buskopplers ACH...

Page 20: ...drate Die Baudrate Datenübertragungsgeschwindigkeit kann entweder auf 500 kBaud oder auf 2 MBaud eingestellt werden Die Baudrateneinstellung an Schalter S1 8 muss der vom Master vorgegebenen Datenübertragungsgeschwindigkeit entsprechen sonst kann der gesamte Bus nicht betrieben werden ACHTUNG Die SMD Schalter dürfen nur bei ausgeschalteter Versorgungsspannung d h in spannungslosem Zustand eingeste...

Page 21: ... Master frei wenn der betreffende Schalter auf ON steht Die Einstellungen wirken sich auf das Sammelsignal Peripheriefehler PF aus Auch bei ausgeschalteter Diagnosemeldung wird die Diagnosemeldung an der betreffenden LED angezeigt Schalter S1 6 Einzelbit Diagnose Um eine Einzelbit Diagnose z B einer SPS zugänglich zu machen kann das Eingangsfeld für alle Lokalbus Teilnehmer vergrößert werden Tabel...

Page 22: ...t werden 4 2 1 Lage der Module im E A Puffer Abhängig vom Modultyp Ventilträger Modul Eingangs oder Ausgangsmodul legen die Module ihre Daten im Ein bzw Ausgangsdatenpuffer des INTERBUS ab Das Power Modul gilt nicht als Teilnehmer 4 2 2 Belegung des Ausgangsdatenpuffers Je nach Einstellung am Schalter S1 1 belegt das Ventilträger Modul im Ausgangsdatenpuffer entweder 2 Byte bis 8 Ventile oder 4 By...

Page 23: ...sgangsmoduls Adressbelegung auf einem Ventilträger Modul bei AVENTICS kompatiblem Master Umschaltventile nutzen nur die Spule 14 Tabelle 10 Adressbelegung auf einem Ventilträger Ventilplatz Spule LED Byte Adresse 1 14 0 A0 0 12 A0 1 2 14 A0 2 12 A0 3 3 14 A0 4 12 A0 5 4 14 A0 6 12 A0 7 5 14 1 A1 0 12 A1 1 6 14 A1 2 12 A1 3 7 14 A1 4 12 A1 5 8 14 A1 6 12 A1 7 9 14 2 A2 0 12 A2 1 10 14 A2 2 12 A2 3 ...

Page 24: ...le 14 Tabelle 11 Adressbelegung auf einem Ventilträger Ventilplatz Spule LED Byte Adresse 1 14 1 A0 0 12 A0 1 2 14 A0 2 12 A0 3 3 14 A0 4 12 A0 5 4 14 A0 6 12 A0 7 5 14 0 A1 0 12 A1 1 6 14 A1 2 12 A1 3 7 14 A1 4 12 A1 5 8 14 A1 6 12 A1 7 9 14 3 A2 0 12 A2 1 10 14 A2 2 12 A2 3 11 14 A2 4 12 A2 5 12 14 A2 6 12 A2 7 13 14 2 A3 0 12 A3 1 14 14 A3 2 12 A3 3 15 14 A3 4 12 A3 5 16 14 A3 6 12 A3 7 ...

Page 25: ...ngsmodulen der Nummer des Bit der SPS Adresse Ist also Eingang 2 des 16 fach Eingangsmoduls mit der SPS Adresse E1 gesetzt kann das Signal an E1 1 gelesen werden Ist die Einzelbit Diagnose mit Schalter S1 6 aktiviert müssen das Status Byte und die Diagnose Byte in der Belegung des Eingangspuffers berücksichtigt werden Informationen zum Status Byte sind im Kapitel 6 4 2 ab Seite 43 zu finden Tabell...

Page 26: ... 5 6 1 52 66 1 M12x1 15 A B C 42 75 15 8 X72 OUT X72 OUT X71 IN X71 IN INTERBUS US1 US2 UL D RC BA RD LD US1 US2 UL D RC BA RD LD FO1 FO2 E IBDIA FO1 FO2 E IBDIA 015 S1 BTN Made in G ermany 1 1 2 0 1 7 9 8 6 5 4 3 2 1 1 4 1 2 1 0 1 1 1 3 5 D 7 IB_DIA D 1 0 5 4 D 2 3 D D D D E24V 16f IB 015 1 827 030 178 D 6 Made in Germany IO 1 n1 1 n Anzahl Ventilplätze A B 1 173 165 2 189 181 3 205 197 4 221 213...

Page 27: ... M12x1 75 42 20 X72 OUT X72 OUT X71 IN X71 IN INTERBUS INTERBUS US1 US2 UL D RC BA RD LD US1 US2 UL D RC BA RD LD FO1 FO2 E IBDIA FO1 FO2 E IBDIA 015 S1 BTN Made in Germany Made in Germany 52 IB_DIA A24V 0 5A IB 015 1 827 030 179 Made in Germany 1 0 2 3 7 6 5 4 IO 1 n1 1 n Anzahl Ventilplätze A B 1 178 5 169 5 2 198 5 189 5 3 218 5 209 5 4 238 5 229 5 5 258 5 249 5 6 278 5 269 5 7 298 5 289 5 8 31...

Page 28: ... Beschriftung des Buskopplers 5 3 2 E A Module E A Module Die Beschriftung der E A Anschlüsse erfolgt direkt auf den E A Modulen Abb 6 links Ausgangsmodul 8 fach rechts Eingangsmodul 16 fach S1 BTN POWER 3 0 1 7 9 8 6 5 4 3 2 1 1 4 1 2 1 0 1 1 1 3 5 D 7 IB_DIA D 1 0 5 4 D 2 3 D D D D E24V 16f IB 015 1 827 030 178 D 6 Made in Germany IB_DIA A24V 0 5A IB 015 1 827 030 179 Made in Germany 1 0 2 3 7 6...

Page 29: ...RM65M DG IB L befinden sich die beiden Rugged Line Steckverbinder X71 IN und X72 OUT für den Anschluss der Lichtwellenleiter Feldbuskabel Rugged Line Abb 7 Feldbus Anschluss mit ankommendem und weiterführendem Feldbuskabel VORSICHT Anliegende elektrische Spannung Verletzungsgefahr durch elektrischen Schlag O Verbinden oder trennen Sie die Anschlüsse immer nur in spannungslosem Zustand X72 OUT X72 ...

Page 30: ... L werden elektrisch versorgt W die Ventile W die Busklemme W alle Eingangsmodule und diejenigen Ausgangsmodule die am Buskoppler angereiht sind Nicht versorgt werden diejenigen Ausgangsmodule die am Power Modul angereiht sind Die Betriebsspannungen US1 und US2 sind gemäß Tabelle 13 anzuschließen Siehe Kapitel 8 1 Die Spezifikationen der Betriebsspannungen gemäß den elektrischen Kenngrößen sind ei...

Page 31: ...V Quelle versorgt O Die 24 V Versorgung muss aus einem Netzteil mit einer sicheren Trennung nach DIN EN 60742 Klassifikation VDE 0551 erfolgen Damit gelten die entsprechenden Stromkreise als SELV PELV Stromkreise nach EN 60364 1 2 4 5 3 US2 P24VN US1 P24VE L24V GND US1 GND US2 AC 24 V FE Tabelle 13 Belegung des Steckverbinders X71 IN und X72 OUT für die Spannungsversorgung am Buskoppler Pin X71 IN...

Page 32: ...Schutzkappe Zubehör zu verschließen um die Schutzart IP 65 zu gewährleisten Die Eingänge sind gemäß Tabelle 15 und die Ausgänge gemäß Tabelle 16 zu verdrahten Tabelle 14 Stromaufnahme am Buskoppler Anschluss Versorgung Gesamtstrom US1 Spannungsversorgung 1 max 2 4 A L24V Logik 0 4 A P24V Eingänge max 2 0 A US2 Spannungsversorgung 2 max 8 3 A P24VV Ventile max 2 3 A P24VA Ausgänge max 6 0 A VORSICH...

Page 33: ...x1 Gerätedose eignet sich der M12x1 Duostecker Max Kabellänge an den Eingängen 30 m 5 4 5 Belegung des Ausgangsmoduls 8 fach A24V 0 5A IB 4 5 1 3 2 Tabelle 15 Belegung der Eingänge beim Eingangsmodul 16 fach E24V 16f IB Pin Signal Belegung 1 P24V Sensorversorgung 2 Eingang 1 3 5 7 9 11 13 15 Sensorsignal 3 PGND Masse für P24V 4 Eingang 0 2 4 6 8 10 12 14 Sensorsignal 5 nicht belegt ACHTUNG Jeder A...

Page 34: ...rischen Kenngrößen einzuhalten 4 5 1 3 2 Tabelle 16 Belegung der Ausgänge beim Ausgangsmodul 8 fach A24V 0 5A IB Pin Signal Belegung 1 2 nicht belegt 3 PGND Masse für P24VA P24VN 4 Ausgang Speisung durch P24VA Buskoppler oder P24VN vom Power Modul 5 nicht belegt VORSICHT Gefährliche Spannungen Bei vorhandenem Power Modul besteht eine interne Verbindung des GND Pin an POWER X10 mit den GND Pins des...

Page 35: ...egung 1 FE Funktionserde 2 P24VN Spannungsversorgung Ausgänge 3 PGND Masse für P24VN 4 nicht belegt 5 nicht belegt 6 nicht belegt ACHTUNG Schaden am Buskoppler Wenn der Masseanschluss PGND nicht ausgeführt wird fließt der gesamte Rückstrom max 6 A max 12 A über den GND Anschluss des Buskopplers was zu Schäden führen kann O Der Masseanschluss PGND an POWER X10 des Power Moduls muss ausgeführt werde...

Page 36: ...en auf Position 1 stehen O Bringen Sie das System in einen definierten Zustand bevor Sie es einschalten O Stellen Sie alle Handhilfsbetätigungen auf Position 0 O Stellen Sie sicher dass sich keine Person innerhalb des Gefahrenbereichs befindet wenn Sie die Druckluftversorgung einschalten O Beachten Sie auch die entsprechenden Anweisungen und Warnhinweise der Betriebsanleitung Ihres VS O Bevor Sie ...

Page 37: ...oduls anschließen 6 Test Inbetriebnahme Diagnose 6 1 Test Vor der Inbetriebnahme sollte die Funktionsfähigkeit und Wirkungsweise der Aktor Sensorsteuerung überprüft werden Zustandsanzeige am Eingangsmodul 16 fach E24V 16f IB Zustandsanzeige am Ausgangsmodul 8 fach A24V 0 5A IB Tabelle 19 Zustandsanzeige am Eingangsmodul 16 fach LED Farbe Bedeutung E0 E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 ...

Page 38: ...Module werden über die LED angezeigt VORSICHT Unkontrollierte Bewegungen der Aktoren beim Einschalten der Pneumatik Es besteht Verletzungsgefahr wenn sich das System in einem undefinierten Zustand befindet und wenn die Handhilfsbetätigungen auf Position 1 stehen O Bringen Sie das System in einen definierten Zustand bevor Sie es einschalten O Stellen Sie alle Handhilfsbetätigungen auf Position 0 O ...

Page 39: ... Lastversorgung US2 vorhanden US2 18 5 V Unterspannung Lastversorgung US2 US2 18 5 V Sicherung defekt Sicherung wechseln siehe Kapitel 7 4 Lastversorgung US2 nicht vorhanden Notaus UL D grün gelb aus Logikversorgung UL vorhanden Logikversorgung UL vorhanden und Überlast Ventiltreiber Sammeldiagnose Logikversorgung UL nicht vorhanden RC grün aus Remotebus Check Anzeige ankommender Fernbus ordnungsg...

Page 40: ...ellenleiterstrecke nicht korrekt angeschaltet oder Systemreserve im geregelten Betrieb erreicht E aus rot Lokalbus ist fehlerfrei Fehler im Lokalbus aufgetreten LED wird vom Busmaster gesetzt IB DIA grün grün blinkt1 grün blinkt2 1 Blinkfrequenz 0 5 Hz 1 s an 1 s aus 2 Blinkfrequenz 2 Hz 0 25 s an 0 25 s aus INTERBUS Diagnose Anzeige der Ventile Lokalbus zu den Ventilen ist fehlerfrei und Bus Rese...

Page 41: ...sse sind nicht nur an den beiden LED Gruppen am Buskoppler bzw an den LED der Lokalbusteilnehmern sondern auch in der Steuerung CMD Software oder SPS erkennbar wenn die entsprechende Diagnosemeldung am SMD Schalter S1 aktiviert ist Tabelle 24 Diagnoseanzeige am Ausgangsmodul 8 fach LED Signal Fehler Beschreibung IB DIA grün grün blinkt1 grün blinkt2 1 Blinkfrequenz 0 5 Hz 1 s an 1 s aus 2 Blinkfre...

Page 42: ...kt Blinkfrequenz 0 5 Hz 1 s an 1 s aus PF Peripheriefehler BK Busklemme Erk Erkennung E Stat Status im Eingangsfeld VM Ventilträger Modul EM Eingangsmodul AM Ausgangsmodul Usp Unterspannung Ül Ks Überlast oder Kurzschluss Tabelle 26 Diagnoseanzeigen lokal am Eingangsmodul in Verbindung mit Diagnosemeldungen zentral an die Steuerung CMD SW bzw SPS Ereignis LED Signal CMD SPS Sensorversorgung P24VE ...

Page 43: ...ingangsdatenbereich sind u a die Spannungsdiagnose und die Ventil Überlastmeldungen enthalten Die Reihenfolge ist vom Typ des Masters abhängig Ein AVENTICS kompatibler Master liest die Eingangsdiagnose Byte in der hier angegebenen Reihenfolge ein bei Siemens kompatiblem Master ist das jeweilige High und Low Byte vertauscht Die Spannungsdiagnosen sind dem Status Byte wie folgt zugeordnet Tabelle 28...

Page 44: ...riebsbereits eines FU Die Kodierung Bits im Eingangsbyte der Fehler siehe Kapitel 6 4 Abb 10 Diagnose des Ventils 4 P24VA P24VV US2 Unterspannung 18 5 V 12 V 0 1 kein Fehler Fehler 5 P24VA P24VV US2 Unterspannung 12 V 0 1 kein Fehler Fehler 6 P24VV US2 Überlast Kurzschluss Sicherung defekt 0 1 kein Fehler Fehler 7 frei Tabelle 29 Spannungsdiagnose im Status Byte Bit Kennung Status Tabelle 30 Statu...

Page 45: ...plette Ventil ein Fehler gemeldet Wird ein Ventil mit nur einer Spule angeschlossen so wird auch ein Fehler gemeldet Tabelle 31 Ventilzuordnung bei Ventil Überlastmeldung Bit Kennung Status 0 Ventil 1 1 0 kein Fehler Fehler 1 Ventil 2 2 Ventil 3 3 Ventil 4 4 Ventil 5 5 Ventil 6 6 Ventil 7 7 Ventil 8 Tabelle 32 Ventilzuordnung bei Ventil Überlastmeldung Bit Kennung Status 0 Ventil 9 1 0 kein Fehler...

Page 46: ...ersucht bis der Anwender eine entsprechende Maßnahme ergreift Die Reihenfolge ist vom Typ des Masters abhängig Ein AVENTICS kompatibler Master liest die Eingangsdiagnose Byte in der hier angegebenen Reihenfolge ein bei Siemens kompatiblem Master ist das jeweilige High und Low Byte vertauscht Tabelle 33 Reihenfolge der Byte bei AVENTICS kompatiblem Master Byte Inhalt E n Diagnose Ventile 0 7 E n 1 ...

Page 47: ...sters abhängig Ein AVENTICS kompatibler Master liest die Diagnose Byte in der hier angegebenen Reihenfolge ein bei Siemens kompatiblem Master ist das jeweilige High und Low Byte vertauscht Die Diagnose LED und die Diagnosemeldungen werden nur gesetzt wenn der entsprechende Ausgang auf 1 angesteuert wird und der Treiberbaustein an diesem Ausgang Überlast Kurzschluss erkennt Tabelle 35 Reihenfolge d...

Page 48: ...rinzip der physikalischen Anordnung Busklemme Ausgangsmodul Eingangsmodul Eingangsmodul Lokalbus Ventilträgermodul Tabelle 38 Aufbau eines Ventilsystems Beispiel ohne Einzelbit Diagnose S1 6 OFF Module Anzahl der belegten Ausgangs Byte Anzahl der belegten Eingangs Byte Busklemme 8 Ventilplätze 2 Eingangsmodul 16 fach 2 Eingangsmodul 16 fach 2 Ausgangsmodul 8 fach 1 Tabelle 39 Aufbau eines Ventilsy...

Page 49: ... Prinzip der logischen Anordnung Abb 12 Prozessdaten Tabelle 40 Abbild des Ausgangsdatenpuffer Ausgangsdatenpuffer Bedeutung Byte 0 Bit 0 0 0 7 1 Byte Ausgänge Ventilträger Modul Byte 1 Bit 1 0 1 7 1 Byte Ausgänge Ventilträger Modul Byte 2 Bit 3 0 3 7 8 Bit Ausgänge Ausgangsmodul 8 fach ...

Page 50: ...Tabelle 42 ID Kennung des Ventilträgermoduls je nach Schalterstellung von S1 6 S1 6 Bedeutung Modultyp ID Kennung Datenbreite OFF keine Einzelbit Diagnose lokales Ausgangsmodul 125 7DHex 1 Wort oder 2 Worte je nach Schalter stellung von S1 1 ON Einzelbit Diagnose lokales Ein und Ausgangsmodul 127 7FHex Tabelle 43 ID Kennung des Eingangsmoduls je nach Schalterstellung von S1 6 S1 6 Bedeutung Modult...

Page 51: ...ucklos bevor Sie am Ventilträger Module elektrisch anschließen O Es dürfen maximal 12 E A Module an einem Ventilsystem montiert sein Strombelastung beachten System ohne Power Modul O Die maximal zulässige Strombelastung an US1 und US2 des Buskopplers für die Ein und Ausgänge muss beachtet werden System mit Power Modul O Unter EMV Aspekten sind die Eingangsmodule vorzugsweise am Buskoppler anzuordn...

Page 52: ... 5 3 Nm Siehe Kapitel 4 und Kapitel 5 5 Anschlüsse herstellen 6 Konfiguration anpassen Abb 13 E A Modul anbauen Bild zeigt HF03 7 2 Power Modul PM12A anbauen Siehe Abbildung 14 Das Ventilsystem soll um das Power Modul erweitert werden um weitere Ausgangsmodule aufnehmen und versorgen zu können Beachten Sie bitte folgendes 2 5 3 Nm X72 OUT X72 OUT X71 IN X71 IN INTERBUS US1 US2 UL D RC BA RD LD US1...

Page 53: ...g Verletzungsgefahr durch elektrischen Schlag O Schalten Sie immer den betreffenden Anlagenteil spannungsfrei und drucklos bevor Sie am Ventilträger Module elektrisch anschließen O Es dürfen maximal 12 E A Module an einem Ventilsystem montiert sein Strombelastung beachten O Unter EMV Aspekten sind die Eingangsmodule vorzugsweise am Buskoppler anzuordnen O Die maximale Anzahl von E A Modulen die di...

Page 54: ... anschrauben 3 Innensechskantschrauben M4 DIN 912 Schlüsselweite 3 Anzugsdrehmoment 2 5 3 Nm 4 Das Power Modul anfügen und anschrauben 3 Innensechskantschrauben M4 DIN 912 Schlüsselweite 3 Anzugsdrehmoment 2 5 3 Nm 5 DierestlichenEingangs AusgangsmoduleamPowerModul anreihen und anschrauben je 3 Innensechskantschrauben DIN 912 M4 Schlüsselweite 3 Anzugsdrehmoment 2 5 3 Nm 6 Nach dem letzten E A Mod...

Page 55: ...euen Buskoppler festschrauben 3 Innensechskantschrauben DIN 912 M4 Schlüsselweite 3 Anzugsdrehmoment 2 5 3 Nm 6 Seitendeckel links wieder anschrauben 3 Innensechskantschrauben DIN 912 M4 Schlüsselweite 3 Anzugsdrehmoment 2 5 3 Nm Siehe Kapitel 4 und Kapitel 5 7 Betriebsarten am neuen Buskoppler einstellen 8 Anschlüsse wieder herstellen VORSICHT Anliegende elektrische Spannung Verletzungsgefahr dur...

Page 56: ...US US1 US2 UL D RC BA RD LD US1 US2 UL D RC BA RD LD FO1 FO2 E IBDIA FO1 FO2 E IBDIA BO SC H 015 S1 BTN Made in G ermany X72 OUT X72 OUT X71 IN X71 IN INTERBUS US1 US2 UL D RC BA RD LD US1 US2 UL D RC BA RD LD FO1 FO2 E IBDIA FO1 FO2 E IBDIA BO SC H 015 S1 BTN Made in G ermany VORSICHT Anliegende elektrische Spannung Verletzungsgefahr durch elektrischen Schlag O Schalten Sie immer den betreffenden...

Page 57: ...ehrfachstecker verbunden sind 3 Die Frontplatte des Buskopplers mit den 6 Schrauben Torx T10 festschrauben Anzugsdrehmoment 2 5 bis 3 0 Nm Dabei Sitz der Dichtung prüfen damit IP 65 gewährleistet bleibt ACHTUNG Beschädigung der Kabelverbindung Die Frontplatte ist über ein Kabel mit Steckverbindung und über 2 Mehrfachstecker mit der Elektronik im Buskoppler verbunden O Damit die Kabelverbindung nic...

Page 58: ...Allgemein Einbaulage beliebig Schutzart nach EN 60529 IEC 529 IP 65 im montierten Zustand Umgebungstemperatur U 0 C bis 50 C Elektrik Nennspannung Logik Un 24 V DC 15 20 Nennspannung Leistung Un 24 V DC 15 20 Ventilansteuerung Ansteuerleistung 0 35 W Elektromagnetische Verträglichkeit Störfestigkeit EN 61000 6 2 Störaussendung EN 61000 4 2 ...

Page 59: ...erungsschaltern darf der Ruhestrom max 2 mA betragen Eingangsverzögerung 0 1 3 ms Eingangsverzögerung 1 0 3 ms Output Ausgänge nach EN 61131 2 8 Halbleiterausgänge Ausgangs Nennspannung 24 V DC Ausgangsspannung bei 1 Signal 24 V DC Spannungsabfall max 1 5 V Ausgangsstrom Nennwert 0 5 A max 0 6 A Ausgangsstrom bei 1 Signal 2 mA bis 0 6 A Allgemein Einbaulage beliebig Schutzart nach EN 60529 IEC 529...

Page 60: ... Rugged Line Phoenix Contact Blindstecker Rugged Line Bestellcode Bestellnummer Ausgangsmodul 8 fach1 1 Lieferung inkl 3 Befestigungsschrauben und Handbuch A24V 0 5A IB 1 827 030 179 Eingangsmodul 8 fach1 E24V 16f IB 1 827 030 178 Power Modul1 P12 1 827 030 161 Zubehör M12x1 Stecker gerade für E A Anschluss 1 834 484 222 M12x1 Stecker gewinkelt für E A Anschluss 1 834 484 223 M12x1 Duostecker gera...

Page 61: ...t and technology 68 3 System Overview 69 3 1 Design 70 3 1 1 Bus coupler 71 3 1 2 16 position E24V 16f IB input module 72 3 1 3 8 position A24V 0 5A IB output module 72 3 1 4 PM12A power module 72 3 2 Electric supply and power supply 72 3 2 1 Bus coupler 72 3 2 2 PM12A power module 74 3 3 Function 75 3 3 1 Bus coupler 75 3 3 2 I O modules 75 3 3 3 PM12A power module 76 4 Configuration 76 4 1 Prese...

Page 62: ... coupler 96 6 3 2 Diagnostic display on the 16 position E24V 16f IB input module 98 6 3 3 Diagnostic display on the 8 position A24V 0 5A IB output module 99 6 4 Diagnostic messages 99 6 4 1 Diagnostic messages to the master 99 6 4 2 Voltage diagnosis in the status byte 101 6 4 3 Input module diagnosis in input data range 104 6 4 4 Output module diagnosis in input data range 105 6 4 5 Example 106 6...

Page 63: ...formation for the safe and appropriate assembly and commissioning of the product It also contains information about operation and maintenance and how to remedy simple malfunctions yourself O Read this documentation completely especially the chapter Notes on Safety before working with the product 1 2 Required and supplementary documentation O Only commission the product once you have obtained the f...

Page 64: ... must be observed Safety instructions are set out as follows W Safety sign draws attention to the hazard W Signal word identifies the degree of hazard W Hazard type and source identifies the hazard type and source W Consequences describes what occurs when the safety instructions are not complied with W Precautions states how the hazard can be avoided SIGNAL WORD Hazard type and source Consequences...

Page 65: ...situation which if not avoided could result in minor or moderate injury NOTICE Indicates that damage may be inflicted on the product or the environment Table 3 Meaning of the symbols Symbol Meaning If this information is disregarded the product cannot be used or operated optimally O Individual independent action 1 2 3 Numbered steps The numbers indicate sequential steps Table 4 Abbreviations Abbre...

Page 66: ...ation in a location where it is accessible to all users at all times O Always include the documentation when you pass the product on to third parties 2 2 Intended use The product is an electropneumatic system component The product may be used as follows W Only use the bus coupler in normal industrial atmospheres An individual license must be obtained from the authorities or an inspection center fo...

Page 67: ...ct It is considered improper use when the product W is used for any application not stated in these instructions or W is used under operating conditions that deviate from those described in these instructions W is changed or converted 2 4 Personnel qualifications The work described in this documentation requires basic electrical and pneumatic knowledge as well as knowledge of the appropriate techn...

Page 68: ...s listed in the product documentation W If unsuitable products are installed or used in safety relevant applications this may result in unintended system operating states that may lead to injuries and or equipment damage Therefore only use a product in safety relevant applications if such use is specifically stated and permitted in the product documentation W You may only commission the product if...

Page 69: ... of the actuators electrical commissioning may only be carried out in a pressure free state W Do not put the system into operation before it is completely assembled as well as correctly wired and configured and after it has been tested 3 System Overview The versatility and flexibility of this valve system enable AVENTICS to support your automation tasks The valves are completely mounted and tested...

Page 70: ...4V 16f IB input module 8 position A24V 0 5A IB output module W PM12A power module X72 OUT X72 OUT X71 IN X71 IN INTERBUS US1 US2 UL D RC BA RD LD US1 US2 UL D RC BA RD LD FO1 FO2 E IBDIA FO1 FO2 E IBDIA 015 S1 BTN Made in G ermany IB_DIA A24V 0 5A IB 015 1 827 030 179 1 827 030 179 Made in Germany Made in Germany 1 0 2 3 7 6 5 4 0 1 7 9 8 6 5 4 3 2 1 1 4 1 2 1 0 1 1 1 3 5 D 7 IB_DIA IB_DIA D 1 0 5...

Page 71: ...s for displaying diagnostic messages for the valves and the fibre optic cable connection Diagnostic display left group Diagnostic display right group Label To identify the bus participant Table 5 LED display on the INTERBUS bus coupler for power supply and remote bus LED Color Meaning US1 Green red Logics and input supply US2 Green red Valves and output supply UL D Green yellow Logics collective d...

Page 72: ...A24V 0 5A IB output module M12x1 connections Module with 16 M12x1 outputs for connecting electrical actuator signals Display W 1 LED green INTERBUS diagnostic display W 8 LEDs yellow 1 LED per output system status display W 8 LEDs red 1 LED per output diagnostic display Label Below the corresponding socket 3 1 4 PM12A power module POWER X10 plug Connection for supplying additional output modules D...

Page 73: ...nsumption on US2 W 2 3 A for P24VV valve supply W 6 0 A for P24VA output supply Reverse polarity protection The L24V P24V and P24VV supply voltages are protected against reverse polarization by means of a diode Fuse The P24VA supply voltage for the outputs is protected against short circuits by a fuse The US2 LED will start blinking if the fuse is defect NOTICE Wrong polarization The US1 and US2 v...

Page 74: ...e valves and outputs is monitored at 18 5 V and 12 V If the value falls below 12 V an emergency signal off is generated and is reported via LEDs and diagnostic information 3 2 2 PM12A power module POWER X10 plug P24VN power supply for outputs whose output modules are connected directly to the power module CAUTION There is an internal connection between the PGND pin on the POWER X10 and the GND con...

Page 75: ...d or the A24V 0 5A IB output modules can also be connected Presettings The data capacity baud rate as well as the releases of diagnostic messages can be set using the SMD S1 switch on the INTERBUS bus coupler 3 3 2 I O modules The input output modules make it possible via separable plug connections to control electrical input and output signals via the valve system s bus connection A maximum of 12...

Page 76: ... The power module does not supply inputs with power The input modules have to be attached directly to the bus coupler for EMC reasons 4 Configuration 4 1 Presettings on the bus coupler Once the S1 screw cap on the bus coupler has been opened you can then use the SMD switch to make the necessary presettings and adjustments to the diagnostic messages When delivered all switches are set to the OFF po...

Page 77: ...tions to Tab 7 S1 1 switch data capacity for valve control The data capacity can be set to either 1 word or 2 words 1 word 16 output bits for 8 valves 2 words 32 output bits for 16 valves NOTICE The SMD switches can only be adjusted when the power supply is switched off i e in a voltage free state S1 BTN POWER 3 1 2 3 4 5 6 7 8 F F O N O Table 7 Presettings SMD S1 switch assignment Switch Function...

Page 78: ...hes diagnostic settings See Fig 2 NOTICE The SMD switches can only be adjusted when the power supply is switched off i e in a voltage free state Table 8 Diagnostic settings SMD S1 switch assignment Switch Function Effect S1 2 Overload of valves outputs module inputs module ON Collective message PF on OFF Collective message PF off S1 3 US1 Low voltage bus terminal overload ON Collective message PF ...

Page 79: ...e diagnostic message is switched off S1 6 switch Single bit diagnosis To make a single bit diagnosis e g accessible to a PLC the input field can be made larger for all local bus participants 4 2 Valve system configuration The valve system is constructed modularly corresponding to the order The local bus participants are connected to the INTERBUS via the bus terminal The order the modules occupy th...

Page 80: ...nect to outputs Output data buffer assignment The number of bits upon output activation is equal to the numbering of the M12x1 sockets on the input output modules If the PLC address A7 is assigned to an output module with 8 outputs then assign bit A7 3 to output 4 for this output module Table 9 Modules with outputs Modules with outputs Number of output bytes assigned1 1 Without single bit diagnosi...

Page 81: ...ble 10 Address assignment on a valve terminal Valve position Solenoid LED Byte Address 1 14 0 A0 0 12 A0 1 2 14 A0 2 12 A0 3 3 14 A0 4 12 A0 5 4 14 A0 6 12 A0 7 5 14 1 A1 0 12 A1 1 6 14 A1 2 12 A1 3 7 14 A1 4 12 A1 5 8 14 A1 6 12 A1 7 9 14 2 A2 0 12 A2 1 10 14 A2 2 12 A2 3 11 14 A2 4 12 A2 5 12 14 A2 6 12 A2 7 13 14 3 A3 0 12 A3 1 14 14 A3 2 12 A3 3 15 14 A3 4 12 A3 5 16 14 A3 6 12 A3 7 ...

Page 82: ...d 14 Table 11 Address assignment on a valve terminal Valve position Solenoid LED Byte Address 1 14 1 A0 0 12 A0 1 2 14 A0 2 12 A0 3 3 14 A0 4 12 A0 5 4 14 A0 6 12 A0 7 5 14 0 A1 0 12 A1 1 6 14 A1 2 12 A1 3 7 14 A1 4 12 A1 5 8 14 A1 6 12 A1 7 9 14 3 A2 0 12 A2 1 10 14 A2 2 12 A2 3 11 14 A2 4 12 A2 5 12 14 A2 6 12 A2 7 13 14 2 A3 0 12 A3 1 14 14 A3 2 12 A3 3 15 14 A3 4 12 A3 5 16 14 A3 6 12 A3 7 ...

Page 83: ...PLC address when the inputs are read If input 2 of an 16 position input module is set using PLC address E1 the signal can be read at E1 1 If the single bit diagnosis is activated with the S1 6 switch the status byte and the diagnosis byte must be taken into account with the input buffer assignment Information on the status byte can be found in chapter 6 4 2 from page 101 onward Table 12 Input data...

Page 84: ... 6 5 4 3 2 1 1 4 1 2 1 0 1 1 1 3 5 D 7 IB_DIA D 1 0 5 4 D 2 3 D D D D E24V 16f IB 015 1 827 030 178 D 6 Made in Germany IO 1 5 4 1 8 3 1 1 1 1 7 5 25 22 8 7 70 B A 5 3 2 4 50 111 118 R X 5 1 3 78 5 9 5 6 1 52 66 1 M12x1 15 A B C 42 75 15 8 X72 OUT X72 OUT X71 IN X71 IN INTERBUS US1 US2 UL D RC BA RD LD US1 US2 UL D RC BA RD LD FO1 FO2 E IBDIA FO1 FO2 E IBDIA 015 S1 BTN Made in G ermany 1 1 2 0 1 7...

Page 85: ...2x1 75 42 20 X72 OUT X72 OUT X71 IN X71 IN INTERBUS INTERBUS US1 US2 UL D RC BA RD LD US1 US2 UL D RC BA RD LD FO1 FO2 E IBDIA FO1 FO2 E IBDIA 015 S1 BTN Made in Germany Made in Germany 52 IB_DIA A24V 0 5A IB 015 1 827 030 179 Made in Germany 1 0 2 3 7 6 5 4 IO 1 n1 1 n number of valve positions A B 1 178 5 169 5 2 198 5 189 5 3 218 5 209 5 4 238 5 229 5 5 258 5 249 5 6 278 5 269 5 7 298 5 289 5 8...

Page 86: ...d identification of the bus coupler 5 3 2 I O modules I O modules The I O connections are inscribed directly on the I O modules Fig 6 left 8 position output module right 16 position input module S1 BTN POWER 3 0 1 7 9 8 6 5 4 3 2 1 1 4 1 2 1 0 1 1 1 3 5 D 7 IB_DIA D 1 0 5 4 D 2 3 D D D D E24V 16f IB 015 1 827 030 178 D 6 Made in Germany IB_DIA A24V 0 5A IB 015 1 827 030 179 Made in Germany 1 0 2 3...

Page 87: ... On the RM65M DG IB L bus coupler there are the Rugged Line X71 IN and X72 OUT plug connectors for connecting the Rugged Line fibre optic fieldbus cable Fig 7 Fieldbus connection with incoming and outgoing fieldbus cable CAUTION Applied voltage Danger of injury from electric shocks O Only connect or disconnect the connections in a voltage free state X72 OUT X72 OUT X71 IN X71 IN INTERBUS US1 US2 U...

Page 88: ...DG IB L bus coupler W the valves W the bus terminal W all input modules and output modules that are aligned to the bus coupler but not the output modules that are aligned to the power module The US1 and US2 operating voltages should be connected in accordance with Tab 13 See chapter 8 1 The operating voltages given in the electrical data characteristics must be adhered to NOTICE Wrong polarization...

Page 89: ...power supply must stem from a power supply unit which is electrically isolated according to DIN EN 60742 classification VDE 0551 The corresponding electrical circuits are thus SELV PELV circuits in accordance with EN 60364 1 2 4 5 3 US2 P24VN US1 P24VE L24V GND US1 GND US2 AC 24 V FE Table 13 X71 IN and X72 OUT plug connector assignment for the voltage supply on the bus coupler Pin X71 IN X72 OUT ...

Page 90: ...on class IP65 unassigned sockets should be covered with the M12x1protective cap accessories The inputs are to be wired in accordance with Tab 15 the outputs in accordance with Tab 16 Table 14 Power consumption on the bus coupler Connection Supply Total current US1 Voltage supply 1 Max 2 4 A L24V Logic 0 4 A P24V Inputs max 2 0 A US2 Voltage supply 2 Max 8 3 A P24VV Valves max 2 3 A P24VA Outputs m...

Page 91: ...th 1 signal each to one M12x1 socket Max cable length at inputs 30 m 5 4 5 Output assignments in the 8 position A24V 0 5A IB output module 4 5 1 3 2 Table 15 Input assignment in the 16 position E24V 16f IB input module Pin Signal Assignment 1 P24V Sensor supply 2 Input 1 3 5 7 9 11 13 15 Sensor signal 3 PGND Ground for P24V 4 Input 0 2 4 6 8 10 12 14 Sensor signal 5 Not connected NOTICE Every outp...

Page 92: ...ered to 4 5 1 3 2 Table 16 Output assignments in the 8 position A24V 0 5A IB output module Pin Signal Assignment 1 2 Not connected 3 PGND Ground for P24VA P24VN 4 Output Fed by P24VA from bus coupler or P24VN from power module 5 Not connected CAUTION Dangerous voltages There is an internal connection between the PGND pin on the POWER X10 and the GND connection on the bus coupler if a power module ...

Page 93: ... Functional earth 2 P24VN Output voltage supply 3 PGND Ground for P24VN 4 Not connected 5 Not connected 6 Not connected NOTICE Damage to the bus coupler If the PGND ground connection is not made all of the reverse current max 6 A max 12 A flows through the bus coupler s GND which could lead to damage O The PGND ground connection to POWER X10 on the power module must be made P24VN PGND AC 24 V FE 1...

Page 94: ...ed actuator movements when the pneumatics are switched on Danger of injury if the system is in an undefined state and the manual overrides are set to position 1 O Put the system in a defined state before switching it on O Set all manual overrides to position 0 O Make sure that no personnel are within the hazardous zone when the compressed air supply is switched on O Also observe the applicable ins...

Page 95: ...ility and operating method of the actuator sensor controls should be checked before start up LED display on the E24V 16f IB 16 position input module LED display on the A24V 0 5A IB 8 position output module Table 19 Status display on 16 position input module LED Color Meaning E0 E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 E15 Yellow Input signal level on high Off Input signal level on low Table ...

Page 96: ... Diagnostic display on the bus coupler The left LEDs on the front panel of the bus coupler show the messages listed in Tab 21 even if the corresponding diagnostic message is deactivated on the master CAUTION Uncontrolled actuator movements when the pneumatics are switched on Danger of injury if the system is in an undefined state and the manual overrides are set to position 1 O Put the system in a...

Page 97: ...ter 7 4 US2 load supply inactive emergency off UL D Green Yellow Off Logic supply UL available UL logics supply active and valve driver overload collective diagnosis Logic supply UL not available RC Green Off Remote bus check display The incoming remote bus has been properly connected and the bus master s bus reset is inactive Computer is in reset mode or the incoming remote bus is incorrectly con...

Page 98: ...ibre optic cable line is disabled or the system has no reserves in normal operation E Off Red No errors in local bus Error in local bus LED is set by bus master IB DIA Green Green blink1 Green blink2 1 Blinking frequency 0 5 Hz 1 s on 1 s off 2 Blinking frequency 2 Hz 0 25 s on 0 25 s off INTERBUS valve diagnostic display No errors in the local bus connected to the valves and the bus master s bus ...

Page 99: ...n Tab 25 are not only recognized by both the LED groups on the bus coupler or on the local bus participant s LED but are also recognized by the control CMD software or PLC if the corresponding diagnostic message on the SMD S1 switch is activated Table 24 Diagnostic display on the 8 position output module LED Signal Error Description IB DIA Green Green blink1 Green blink2 1 Blinking frequency 0 5 H...

Page 100: ... blink Blinking frequency 0 5 Hz 1 s on 1 s off PF Peripheral error BK Bus terminals Erk ID E Stat Status in input field VM Valve terminal module EM Input module AM Output module Usp Low voltage Ül Ks Overload or short circuit Table 26 Local diagnostic display on the input module with centralized diagnostic messages on the control CMD SW or PLC Event LED signal CMD PLC P24VE sensor supply active D...

Page 101: ... the type of master used A master compatible with AVENTICS systems reads the input diagnosis bytes in the order given below with masters compatible with Siemens the high and low bytes are exchanged The voltage diagnoses are assigned to the status byte as follows Table 28 Byte order with AVENTICS compatible masters Byte Contents E n Status byte E n 1 Diagnosis valve 1 8 E n 2 Empty byte E n 3 Diagn...

Page 102: ...e The diagnosis of the valve interruption short circuit is always reported and indicates that the valve is ready for operation compare with readiness for operation of a frequency converter For coding bits in input byte of the errors see chapter 6 4 Fig 10 Valve diagnosis Table 30 Status display Control Status no error in valve Status error in valve Off 1 0 interruption On 1 0 short circuit 24 V Co...

Page 103: ...rror is reported for the complete valve If a valve with only one solenoid is connected then an error is also reported Table 31 Valve assignment with valve overload message Bit ID Status 0 Valve 1 1 0 No error Error 1 Valve 2 2 Valve 3 3 Valve 4 4 Valve 5 5 Valve 6 6 Valve 7 7 Valve 8 Table 32 Valve assignment with valve overload message Bit ID Status 0 Valve 9 1 0 No error Error 1 Valve 10 2 Valve...

Page 104: ... to restart the system unless the user takes appropriate action The order depends on the type of master used A master compatible with AVENTICS systems reads the input diagnosis bytes in the order given below with masters compatible with Siemens the high and low bytes are exchanged Table 33 Byte order with AVENTICS compatible masters Byte Contents E n Inputs 0 7 E n 1 Inputs 8 15 E n 2 Empty byte E...

Page 105: ...ed A master compatible with AVENTICS systems reads the input diagnosis bytes in the order given below with masters compatible with Siemens the high and low bytes are exchanged The diagnostic LED and the diagnostic messages are only active if the output is set to 1 and the driver component acknowledges this overload short circuit on this particular output Table 35 Byte order with AVENTICS compatibl...

Page 106: ...assignment Bus terminals Output module Input module Input module Local bus Valve terminal module Table 38 Configuration of a valve system example without single bit diagnosis S1 6 OFF Modules Number of output bytes assigned Number of input bytes assigned Bus terminals 8 valve positions 2 16 position input module 2 16 position input module 2 8 position output module 1 Table 39 Configuration of a va...

Page 107: ...Testing start up diagnosis AVENTICS INTERBUS R412005655 BDL 001 AB 107 English Fig 11 Principle of logical assignment Fig 12 Process data ...

Page 108: ... OFF Input data buffer Meaning Byte 0 Bit 0 0 0 7 8 bit inputs 1 16 position input module Byte 1 Bit 1 0 1 7 8 bit inputs 1 16 position input module Byte 2 Bit 2 0 2 7 8 bit inputs 2 16 position input module Byte 3 Bit 3 0 3 7 8 bit inputs 2 16 position input module Table 42 ID of the valve terminal module depending on the S1 6 switch position S1 6 Meaning Module type ID Data capacity OFF No singl...

Page 109: ...nd output module 191 BFHex 1 Byte E 1 Byte A CAUTION Applied voltage Danger of injury from electric shocks O Make sure the relevant system component is not under voltage or pressure before electrically connecting modules to the valve terminal O A maximum of 12 I O modules can be mounted on one valve system Observe the current load System without a power module O The maximum permissible current loa...

Page 110: ...2 M4 wrench width 3 Tightening torque 2 5 3 Nm See chapter 4 and 5 5 Reestablish connections 6 Adjust configuration Fig 13 Adding an I O module picture shows HF03 2 5 3 Nm X72 OUT X72 OUT X71 IN X71 IN INTERBUS US1 US2 UL D RC BA RD LD US1 US2 UL D RC BA RD LD FO1 FO2 E IBDIA FO1 FO2 E IBDIA BO SC H 015 S1 BTN Made in G ermany X72 OUT X72 OUT X71 IN X71 IN INTERBUS US1 US2 UL D RC BA RD LD US1 US2...

Page 111: ... 0 5 4 D 2 3 D D D D E24V 16f IB 015 1 827 030 178 D 6 Made in Germany CAUTION Applied voltage Danger of injury from electric shocks O Make sure the relevant system component is not under voltage or pressure before electrically connecting modules to the valve terminal O A maximum of 12 I O modules can be mounted on one valve system Observe the current load O The input modules should preferentially...

Page 112: ...dd the power module and screw it tight 3 hexagon socket head screws DIN 4 M912 wrench width 3 Tightening torque 2 5 3 Nm 5 Line up the rest of the input output modules on the power module and screw them tight 3 hexagon socket head screws each DIN 912 M4 wrench width 3 Tightening torque 2 5 3 Nm 6 Screw the left side cover back on after the last I O module 3 hexagon socket head screws DIN 4 M912 wr...

Page 113: ...ews DIN 912 M4 wrench width 3 Tightening torque 2 5 3 Nm 6 Screw the left side cover back on 3 hexagon socket head screws Din 912 M4 wrench width 3 Tightening torque 2 5 3 Nm See chapter 4 and 5 7 Set the operating modes on the new bus coupler 8 Reestablish connections Fig 15 Exchanging the bus coupler 2 5 3 Nm X72 OUT X72 OUT X71 IN X71 IN INTERBUS US1 US2 UL D RC BA RD LD US1 US2 UL D RC BA RD L...

Page 114: ...8 A FF8A CAUTION Applied voltage Danger of injury from electric shocks O Make sure the relevant system component is not under voltage or pressure before electrically connecting modules to the valve terminal NOTICE Damage to the cable connection The front panel is connected to the plug connector via a cable and to the bus coupler s electronics via 2 multiple plugs O In order to prevent damage to th...

Page 115: ...The front panel should be reattached far enough to connect the tight plug contacts on both the multiple plugs 3 Screw the front panel of the bus coupler in place with the 6 Torx T10 screws Tightening torque 2 5 to 3 0 Nm To assure the IP 65 protection level make sure the gasket is correctly seated FF8A Fig 16 Position of the fuse on the back of the bus coupler s front panel ...

Page 116: ...s coupler General Mounting orientation Any Protection class according to EN 60529 IEC 529 IP 65 when assembled Ambient temperature U 0 C to 50 C Electrics Logic nominal voltage Un 24 V DC 15 20 Output nominal voltage Un 24 V DC 15 20 Valve control Control power 0 35 W Electromagnetic compatibility Interference immunity EN 61000 6 2 Interference emission EN 61000 4 2 ...

Page 117: ...witch with idle current of max 2 mA connectable Input delay 0 1 3 ms Input delay 1 0 3 ms Output Outputs according to EN 61131 2 8 semiconductor outputs Rated output voltage 24 V DC Output voltage at 1 signal 24 V DC drop in voltage max 1 5 V Output current Nominal value 0 5 A max 0 6 A Output voltage at 1 signal 2 mA to 0 6 A General Mounting orientation Any Protection class according to EN 60529...

Page 118: ...nnection cable Phoenix Contact Rugged Line dummy plug Order code Order number 8 position output module1 1 Delivery includes 3 attachment bolts and manual A24V 0 5A IB 1 827 030 179 8 position input module1 E24V 16f IB 1 827 030 178 Power module1 P12 1 827 030 161 Accessories M12x1 plug straight for I O connection 1 834 484 222 M12x1 plug angled for I O connection 1 834 484 223 M12x1 duo plug strai...

Page 119: ...Characteristics service parts and accessories AVENTICS INTERBUS R412005655 BDL 001 AB 119 English ...

Page 120: ... obligation of own judgement and verification It must be remembered that our products are subject to a natural process of wear and aging An example configuration is depicted on the title page The delivered product may thus vary from that in the illustration Translation of the original operating instructions The original operating instructions were created in the German language R412005655 BDL 001 ...

Reviews: