BCM450 Hardware & Installation
32
NN40011-001 Issue 1.2 BCM450 Rls 6.0
configured within Element Manager. During the MBM‘s configuration by
Element Manager, the required dipswitch settings will be displayed within the
Element Manager interface. The example below is for illustrative purposes
only with dipswitch settings that may differ from those required for your own
configuration.
Media bay modules can be installed as follows:
Note:
Do not install MBM‘s whilst the BCM is powered up, as the Media Bay
Modules are
not
‗hot swappable‘.
1.
Verify that the Media Bay Module‘s dipswitches have been set
correctly. Please refer to the
BCM450 Media Bay Modules Guide
for
details.
2. Attach one end of a grounding strap to your wrist and the other end to a
grounded metal surface.
3. With the face of the MBM facing toward you, insert the MBM into the
required MBM bay on the main unit or the expansion cabinet.