BCM450 Hardware & Installation
38
NN40011-001 Issue 1.2 BCM450 Rls 6.0
Powering Up the BCM
1. Ensure your BCM450 power supply is connected to the BCM450
system and to an AC wall outlet or a UPS.
2. Ensure the telephony cables are connected to the BCM450 main unit
and BCM450 expansion unit.
3.
The BCM‘s power on / off switch is located to the rear of the unit.
4. If you have a BCM450 with a Redundant Power Supply, ensure both on
/ off switches are in the on position.
5. When the power is turned on the BCM will start the boot sequence.
Check the Power and Status LEDs on the main unit.
6. After the BCM450 starts, both LEDs must be solid green.
7. If either LED is not solid green, there is a problem with the main unit.
8. If this system has an expansion cabinet, check the Power and Status
LEDs on the media bay modules (MBM) in the expansion cabinet. Both
LEDs must be solid green. If either LED is not solid green, there is a
problem with the MBM or the expansion cabinet.
9. Once the system has powered up the system can then be configured.
LED Status
Information regarding the status of the BCM450 system can be obtained from
the LEDs that are visible on the front of the main unit of the BCM. The LEDs
can be viewed to help determine if the BCM is functioning properly and if there
are any system generated alarms.