CHAPTER 5
Instructions, use and maintenance manual
Page 40
D r a g o P 1 P L U S
5.5.3.
OVEN INSTALLED OUTDOORS, WITH OVEN LOADING DOOR IN A
SEPARATE ROOM (INDOORS)
In this case, the oven in which the burner is installed is outdoors, while the oven loading door is positioned
indoors.
However, for proper operation, the burner and the oven loading door have to take in air from the same environment
in order to avoid pressure differences that may result in malfunctions.
In case the burner has to be installed in this type of environment, the following needs to be done:
STEP
ACTION
1
Create an air intake opening under the oven loading door with minimum dimensions of 500 x 500 mm.
2
Completely close the external perimeter of the oven base, so that the burner can take in air only from
the same environment as the oven loading door.
3
Carry out all the operations described in the paragraph “OVEN INSTALLED INDOORS”.
The proper installation is shown in the following figures:
CORRECT
OK
INCORRECT
NO