1
9
Service lift door switch
1.
Open the service lift door.
2. Press the
UP and DOWN buttons on the Main control box.
The green light must be OFF and the service lift must not move
UP
or
DOWN
.
3.
Close the service lift door and ascend the lift electrically a few centimeters at a height no
corresponding to the platform.
The service lift door is only able to open by turning the emergency release lever up.
Fall arrest device
1.
Ascend the lift electrically a few centimetres and observe the centrifugal weight during this
process.
2.
Activate the fall arrest device by turning the lock lever counterclockwise.
3.
Press and hold the down button of the user control box.
The service lift should not descend.
4.
Try to perform a manual descent and observe the centrifugal weight during this process.
The
fall arrest device must support the load (if not, leave the lift and tag it out).
5.
Ascend electrically again to unload the fall arrest device.
6.
Unlock the fall arrest device by turning the unlock lever clockwise.
There is an alternative method for checking the fall arrest device functionality, called the
Stomp-test. The procedure is explained in the Stomp-test
/TYZX[IZOUT'VVKTJO^
.
Top obstruction device
1.
Activate the top stop by pressing it down.
The service lift should not ascend until top obstruc
tion device is released.
EMERGENCY top limit switch
1.
Press the
UP button on the Main control box and during upward travel, press the
EMERGENCY top limit switch manually.
The service lift shall stop immediately. Neither upward nor downward travel should
now be possible.
Function/System
Operations
Bottom obstruction device
1.
Descend the service lift until the bottom obstruction device hits the bottom platform.
The serv
ice lift must stop before the rubber bumpers hit the bottom platform.
The
service lift door and
the fence door must be unlocked.
Manual descent
1.
Perform a manual descent test for one meter.
The service lift must descend and the buzzer must sound
.
Trapped key (if installed)
1.
Turn the Trapped key to the OFF position (if installed)
The service lift should not move
UP or DOWN.
DANGER
)FANYFAULTSOCCURDURINGWORK
s
3TOPWORKING
s
)FREQUIREDSECURETHEWORKPLACE
s
2ECTIFYTHEFAULT
DANGER
-AKESURETHATNOBODYISEXPOSEDTODANGERBELOWTHESERVICELIFTFORINSTANCEFROMFALLINGPARTS