3.3 Space Heating, Space Cooling and Domestic Hot Water
Floor heating loops & Heating radiator & Fan coil units are used for space heating , fan coil units are used
for space cooling. Domestic hot water is supplied from the domestic hot water tank connected to the hydronic
box. The unit switches to heating or cooling mode according to the temperature detected by the room
thermostat. In space cooling mode, the 2way valve is closed to prevent cold water entering the floor heating
loops & Heating radiator.
REMARK
1
Outdoor unit
12
Mixing valve and mixing water pump
2 Hydronic
box
13
Distributor
3
Plate heat exchanger
14
Distributor
4
Backup electric heater(optional)
15
Bypass valve
5
Internal circulator pump
16
Electric heating
6
Wired controller
17
Domestic hot water tank
7
Stop valve
18
Coil in the water tank
8
Motorized 3way valve
RDT Heating Radiator
9
Balance water tank
FLH Floor heating loops
10
External circulation pump
FCU Fan coil units
11 Twoway
valve
RT
Room
thermostats