12
5 Electrical connection
►
Disconnect power.
►
Connect device (depending on the type selected):
Cor colours
BK
black
BN
brown
BU
blue
WH
white
Colours to DIN EN 60947-5-2
OUT1 Switching output
OUT2 Teach: Programming wire
Cor colours
BK
black
BN
brown
BU
blue
WH
white
Colours to DIN EN 60947-5-2
OUT1 Switching output - IO-Link
OUT2 Analogue output
Technical data and further information at →
www.autosen.com
6 Set-up
Note the LED behaviour for the set-up:
Echo LED green
On
Echo is received.
Off
No echo (object / background not detected).
Off
For the time of resetting to factory setting.
Status LEDs yellow
Function acknowledgement
Flashes 1 Hz
Programming mode active.
Flashes 2.5 Hz
Setting distance P1 completed.
Flashes 4 Hz
Setting distance P2 completed or
assignment acknowledgement of the setting.
Flashes 10 Hz
Inverting the switching characteristics.
L-
L+
BN
BU
WH
4
2
1
3
BK
2:Teach
4
2
1
3
BN
BU
WH
BK
L-
L+
Pin 4: IO-Link
AU001-AU003
AU004-AU010
Summary of Contents for AU001