15
AU004-AU010
Start programming mode of the device.
(7.2)
►
Objekt auf Position P1.
►
Taste 1 x 1 s drücken
> LED blinkt (2,5 Hz).
►
Objekt auf Position P2.
►
Taste 1 x 1 s drücken
> LED blinkt (4 Hz).
> If programming is not completed
successfully, the LED does not
flash and the instrument returns to
the previous setting.
10 Inverting the output response
► Connect teach input > 6 s → 7 Wire programming. (AU001-AU003)
►
Press button > 6 s. (AU004-AU010)
> LED flashes (> 10 Hz).
> Output functions are inverted (NO becomes NC or vice versa).
11 Restore factory setting
►
Align the device so that no echo is received.
►
Go into the programming mode of the unit.
► Connect teach input 1 s → 7 Wire programming. (AU001-AU003)
►
Press button once for 1 s. (AU004-AU010)
> LED flashes shortly with 4 Hz.
12 Operation
►
Check whether the unit operates correctly.
> Display by LEDs:
Green LED is lit.
Echo is received.
Yellow LED is lit.
Switching output is switched.
Green LED flashes.
Short circuit at the output.
The minimum distance between the “Proximity Switch Metal Enclosure“ and any “External uninsulated live part“
shall be at least 12.7 mm.
B
P1/P2
Y
X
Y
X
1
2
Output response of the switching
/ analogue output
X: Distance
Y: Output response
①:
OUT1 (switching output)
②:
OUT2 (switching output / analogue output)
B: Blind zone
P1: Setting point 1 (OUT1)
P2: Setting point 2 (OUT2)
Summary of Contents for AU001