5
UK
3.1 Applications
Type of pressure: Relative pressure
Order
number
Measuring range
Pressure resistance
(max. permissible
pressure) *
)
Bursting
pressure
bar
psi
bar
psi
bar
psi
Pressure sensors with G¼ internal thread
AP010
0���400
0…5800
800
11580
1700
24650
AP009
0���250
0…3625
500
7250
1200
17400
AP008**
0���100
0…1450
300
4350
650
9400
AP007**
-1���25
-14,5…362,5
150
2175
350
5075
AP006**
-1���10
-14,6…145
75
1087
150
2175
*
)
With static overload pressure or max� 100 million pressure cycles�
**
)
Use devices with a measuring range ≥ 250 bar for gas applications > 25 bar!
MPa = (measured value in bar) ÷ 10
kPa = (measured value in bar) x 100
Avoid static and dynamic overpressure exceeding the specified overload
pressure by taking appropriate measures�
The indicated bursting pressure must not be exceeded�
Even if the bursting pressure is exceeded only for a short time, the unit
may be destroyed� ATTENTION: Risk of injury!
The units are vacuum resistant. With a nominal pressure range ≤
300 mbar observe the specifications in the data sheet!
Pressure Equipment Directive (PED):
The units comply with the Pressure Equipment Directive and are designed
and manufactured for group 2 fluids in accordance with the sound
engineering practice�
Use of group 1 fluids on request!