23
UK
Display colour change with parameter
[r-cF]
independent of OUT1�
Display colour change with parameter
[G-cF]
independent of OUT1�
1
cFL
2
cFH
1
cFL
2
cFH
Measured value between cFL and cFH;
Display = red
Measured value between cFL and cFH;
Display = green
Colour change display green
Colour change display red
1
Initial value of the measuring range
2
Final value of the measuring range
cFL Lower limit value (independent of the output function)
cFH Upper limit value (independent of the output function)
10 Operation
After power on, the unit is in the Run mode (= normal operating mode)� It carries
out its measurement and evaluation functions and provides output signals
according to the set parameters�
Operation indication → 7 Operating and display elements.
10.1 Read set parameters
► Press [●].
► Press [
▲
] or [
▼
] until the requested parameter is displayed�
► Briefly press [●].
> The unit displays the corresponding parameter value for approx� 30 s; then it
changes to the process value display�