5. Drive by PC
45
© Copyright Reserved Autonics Co., Ltd.
5.3.2
Parameter Tab
Configure operation parameter and required parameter for X or Y-axis.
The configurable range of each item is displayed in Range of Value. In online status, if each value is
changed, the value is automatically added to the main body�
The Parameter tab is listed in the following table�
For more information, refer to"3�1�2 Parameter"
Display
Input range
Factory default
Speed Multiplier
1 to 500
10
Acceleration Rate
1 to 8,000
400
Deceleration Rate
1 to 8,000
400
Start Speed
1 to 8,000
50
Drive Speed 1
1 to 8,000
10
Drive Speed 2
1 to 8,000
100
Drive Speed 3
1 to 8,000
1,000
Drive Speed 4
1 to 8,000
8,000
Post Timer 1
1 to 65,535 (msec)
10
Post Timer 2
1 to 65,535 (msec)
100
Post Timer 3
1 to 65,535 (msec)
1,000
Home Search Low Speed
1 to 8,000
20
Home Search High Speed
1 to 8,000
1,000
Home Search Offset
-8,388,608 to +8,388,607
※
1
+100
Soft Ware Limit +
-8,388,608 to +8,388,607
※
1
+8,388,607
Soft Ware Limit -
-8,388,608 to +8,388,607
※
1
-8,388,608
End Pulse Width (msec)
1 to 65,535 (msec)
100
Pulse Scale Numerator
1 to 65,535
1,000
Pulse Scale Denominator
1 to 65,535
1,000
※
1: When the numerator and the denominator of pulse scale are equal�