3. Configuration of the Operating Mode and System Parameters
21
© Copyright Reserved Autonics Co., Ltd.
(2)
Home Signal Level (nSTOP1)
With the step 2, this mode configures the active level of the home signal (nSTOP1).
Display
Selection
Factory default
Home Signal Level (nSTOP1)
Low (GEX connection)/High (Open)
Low
Home signal on each axis is pin #10 of connector CN4 and 5.
For the active level, in case of selecting Low, the detecting operation of the step 2 started�
If the signal is connected to the GEX, the drive stops evaluating that the signal is active.
In case of High, the drive goes slow and stops evaluating that the opened signal is active�
(3)
Z Signal Level (nSTOP2)
With the step 3, this mode configures the active level of the Encoder Z-phase signal (nSTOP2).
Display
Selection
Factory default
Z Signal Level (nSTOP2)
Low (GEX connection)/High (Open)
Low
The encoder Z-phase signal (nSTOP2) of each axis is pin #9 of connector CN4 and 5.
For the active level, in case of selecting Low, the detecting operation of the step 3 starts�
If the signal is connected to the GEX, the drive stops evaluating that the signal is active. When high, the
drive stops evaluating that the opened signal is active�
(4)
Step 1 to Step 4 Enable
This mode configures the Enable/Disable for each step.
Display
Selection
Factory default
Step 1 Enable to Step 4 Enable
Disable / Enable
Disable
If Disable is selected, the step is disabled and move to the next step�
If Enable is selected, the search operation of each step is carried in the specified direction.
(5)
Step 1 to Step 4 Direction
This mode configures the direction of each mode.
Display
Selection
Factory default
Step 1 Direction to Step 4 Direction
+/-
Step 1, 2
:-
Step 3, 4
:+
If + is configured, the drive pulse comes out to the + direction of the detection direction.
If - is configured, the drive pulse comes out tn the - direction of the detection direction.
(6)
Position Clear
When the home search ends, this mode clears the position counter�
Display
Selection
Factory default
Position Clear
Disable / Enable
Enable