3. Configuration of the Operating Mode and System Parameters
26
© Copyright Reserved Autonics Co., Ltd.
Caution
1� Step 1 and Step 2 have the same direction�
2� Step 4 must be enabled and step 1 and step 2 are ended after escaping the limit in reverse�
3� Step 3 is entered in the opposite direction of step 1 and step 2�
4. Limit Stop Mode is set as Slow in Mode tab.
[Mode]
Item
Configuration value
Note
Limit Stop Mode
Slow
Deceleration stop
Limit Active Level
Low
[Parameter]
Item
Configuration value
Note
Speed Multiplier
10
Acceleration Rate
400
Able to decelerate to stop within the active block
of limit signal (In case Deceleration Value is set to
Accel in Mode tab.)
Start Speed
50
Start Speed of trapezoid drive
Home Search Low Speed
20
Slower than the start speed of 200 pps
Home Search High Speed
1,000
10,000pps
Home Search Offset
500
Required distance to escape the limit range