6 Installation and network wiring
26
© Copyright Reserved Konics Co., Ltd.
6.2
Network wiring
This network consists of below items.
DeviceNet cable (arterial and feeder)
DeviceNet power
Terminating resistances
Tap (selectable)
Grounding
Thick line: arterial, Thin line: feeder
NODE
The point of connection the DeviceNet master and a slave device.
Arterial
At this cable, terminating resistances are installed at both ends.
Feeder
This cables are divided from arterial.
Branch
When dividing as feeders from an arterial, use branch taps.
(When not using branch taps, it is Multi Drop method wiring.)
(1)
DeviceNet cable
Power and communication signal are within one cable.
White and blue cables are communication signal cable and red and black cables are power
cable.
You must use the DeviceNet standard cable.
Com.
speed
Cable
Feeder length Total feeder
length
Thick cable
Thin cable
125K
Max. 500m
100m
Max. 6m
Max. 156m
250K
Max. 250m
-
Max. 6m
Max. 78m
500K
Max. 100m
500m
Max. 6m
Max. 39m
Summary of Contents for ARD Series
Page 1: ... Copyright Reserved Autonics Co Ltd iii USER MANUAL ...
Page 2: ...ii Copyright Reserved Autonics Co Ltd ...
Page 9: ...1 Product overview Copyright Reserved Autonics Co Ltd 9 ...
Page 13: ...1 Product overview Copyright Reserved Autonics Co Ltd 13 ...
Page 16: ...3 Dimensions 16 Copyright Reserved Konics Co Ltd 3 Dimensions unit mm Panel cut out ...
Page 17: ...3 Dimensions Copyright Reserved Autonics Co Ltd 17 ...
Page 29: ...6 Installation and network wiring Copyright Reserved Autonics Co Ltd 29 ...
Page 81: ...8 Unit parameter setting Copyright Reserved Autonics Co Ltd 81 ARD AO04 ...
Page 103: ...9 DeviceNet Explicit Message Copyright Reserved Autonics Co Ltd 103 ...
Page 113: ...10 Parameter Copyright Reserved Autonics Co Ltd 113 MOO ARDAU1 V1 0 1303US ...