PRE-INSTallaTION ChECkS
Preliminary checks
The garage door should operate manually without any points of resistance. Check that it is in good mechanical condition (pulleys, supports, etc.)
and perfectly balanced (spring tension).
It is dangerous to perform any operation on the door springs (the door may fall).
The structures of your garage (walls, lintel, partitions, cross members, door rails, etc.) enable the Spider Pro 600 to be fixed securely. Strengthen
these if necessary.
Do not spray water onto the device. The Spider Pro 600 must not be fitted in an area prone to water splashes.
The bottom of the door must be equipped with a rubber profile to avoid rough contact and to increase the contact surface area.
If the garage door is the only access to the garage, fit an external back release (external lock unlocked by a key or an external unlocking device and
incorporate a backup battery.
If the garage door faces a public road, fit an orange light type signal device.
Check that there are no dangerous parts accessible on the door; if necessary protect them.
Unlocking the door can cause uncontrolled movement if the door is incorrectly balanced.
Safety instructions
The safety instructions must be followed throughout the installation:
• Take off your jewellery (bracelet, chain, etc.) during installation.
•
For drilling and welding operations, wear special glasses and appropriate protection.
•
Use the appropriate tools.
•
Be careful when handling the motorisation system to prevent any risk of injury.
•
Do not connect the unit to the power supply or to the backup battery before the installation process is complete.
• Never use high pressure cleaning equipment.
INSTallaTION
height of the installation
fig. 3
Measure the distance “D” between the highest point of the door and the ceiling.
If “D” is between 35 and 200 mm, secure the assembly directly to the ceiling.
If “D” is greater than 200 mm, secure the assembly so that the height “H” is between 10 and 200 mm.
Information about the various installation stages
fig. 4 to 14
mounting the lintel yoke and door yoke (fig. 4)
In the case of a door being installed directly on the ceiling (attached ceiling), the lintel yoke may be fixed to the ceiling and, if necessary, have an
offset of 200 mm max in relation to the lintel.
(fig. 4- )
.
assembling the 2-part rail (fig. 5)
[1] [2] [3]
.
Unfold the 2 sections of the rail.
Ensure that the chain or belt is not twisted.
[4]
.
Assemble the 2 sections of the rail using the sleeve.
[5]. Secure the assembly using 8 mounting screws.
[6]. Tighten the nut to tension the chain or belt. The compressed rubber must measure between 18 and 20 mm.
The mounting screws must not penetrate the rail (do not drill).
In the case of an attached ceiling installation, do not use the sleeve mounting screws.