background image

automatismos

 pujol - 

7

 - 

english

SPIDER PRO 600

memorising the remote controls for operation in «Total opening» mode 

fig. 25

The remote controls supplied in the kit have already been memorised.
It is possible to memorise up to 32 control channels.
If this procedure is carried out using a channel which has already been memorised, this channel will be cleared.

SPECIfIC OPERaTION

See the user booklet.

ClEaRING ThE REmOTE CONTROlS aND all SETTINGS

Clearing the remote controls 

fig. 26

Press button “

B

” until the light flashes (7 secs).

Causes all memorised remote controls to be cleared.

Reinitialising all settings 

fig. 27

[1]. Press button “

a

” 3 times to access the 

auto-programming parameter.

[2]. Press button «

B

” to enter auto-programming mode. Warning light B flashes twice continuously. 

[3].  Control the motor with button “

a

” so that the transmission shuttle is engaged on the carriage and brings the door to the closed position.

[4].  Press “

B

” to launch the auto-programming cycle. 

 

The door performs a complete Opening-Closing cycle.

 - If the auto-programming is correct, warning light B goes out.
 -

If the auto-programming cycle was not successful, warning light B flashes twice continuously.

REfITTING ThE COvER flaP 

(fig. 28)

Fit the cover flap.

DIaGNOSTICS

Warning light B 

meaning

Solution?

 

Motor waiting for auto-programming

Start auto-programming

 

 

Cell fault

Check that no obstacles prevent the cells from detecting.

Check the wiring of the cells or create a bridge between 

terminals 1 and 2 if no cells are installed.

Check the correct alignment of the cells.

 

 

Motor thermal protection device

Leave the motor to cool until the fault disappears.

 

 

Motor current measuring circuit fault or sensor fault

Switch off the power supply (mains and backup battery), wait 

a few minutes then reconnect the power supply.  

Perform an auto-programming cycle. If the fault remains, 

contact automatismos pujol technical assistance.

7

Maximum power delivered by the motor reached during the 

auto-programming phase 

Product has reached operating limit.

https://appceso.com

Summary of Contents for SPIDER PRO 600

Page 1: ...nstructions de montage et r glage Installation and adjustment instructions SPIDER PRO 600 Servicio T cnico Post Venta Service Technique Apres Vente After sales Technical Service 5072365A T 34 902 199...

Page 2: ...https appceso com...

Page 3: ...los mandos a distancia para el funcionamiento en Apertura total 5 prueba de funcionamiento 6 Utilizaci n de los telemandos 6 Funcionamiento de la detecci n de obst culos 6 Funcionamiento de la luz in...

Page 4: ...jable guardarlo a proximidad inmediata de la puerta Pegue bien la etiqueta relativa al dispositivo de accionamiento manual cerca de su elemento de maniobra Pegue bien las etiquetas de advertencia cont...

Page 5: ...cadenas u otros durante la instalaci n En el caso de las operaciones de taladrado y soldadura utilice gafas especiales y las protecciones adecuadas Utilice las herramientas adecuadas Manipule con pre...

Page 6: ...n el primer agujero del ra l en el exterior de los finales de carrera Procure insertar al m ximo el cojinete de manera que la pesta a de posicionamiento sobresalga por el exterior del ra l Verificaci...

Page 7: ...rendizaje es correcto el indicador B se apaga Si el ciclo de autoaprendizaje no se ha desarrollado correctamente el indicador B sigue intermitente dos intermitencias Durante el autoaprendizaje Si la p...

Page 8: ...rico general Fig 19 C lulas fotoel ctricas Fig 20 Al colocar las c lulas suprima el puente realizado entre los bornes 1 y 2 Si se suprimen las c lulas es preciso volver a hacer el puente entre los bor...

Page 9: ...ciclo completo de apertura y cierre Si el autoaprendizaje es correcto el indicador B se apaga Si el ciclo de autoaprendizaje no se ha desarrollado correctamente el indicador B parpadea dos veces en co...

Page 10: ...V 15 W Salida para alimentaci n de los accesorios 24 V 500 mA m x Entrada de antena desplazada S Entrada para bater a auxiliar Autonom a S 24 horas de 5 a 10 ciclos en funci n de la puerta Tiempo de...

Page 11: ...l commandes pour le fonctionnement en Ouverture totale 5 essai de fonctionnement 6 Utilisation des t l commandes 6 Fonctionnement de la d tection d obstacle 6 Fonctionnement de l clairage int gr 6 Rac...

Page 12: ...e de manoeuvre amovible il est recommand de le ranger proximit imm diate de la porte Fixer demeure l tiquette concernant le dispositif de d pannage manuel pr s de son organe de manoeuvre Fixer demeure...

Page 13: ...z vos bijoux bracelet cha ne ou autres lors de l installation Pour les op rations de per age et de soudure portez des lunettes sp ciales et les protections ad quates Utilisez les outils appropri s Man...

Page 14: ...uniquement Positionner chacun des coussinets dans le premier trou du rail l ext rieur des fins de courses Veiller enfoncer au maximum le coussinet de fa on que l ergot de positionnement d passe l ext...

Page 15: ...verture Fermeture complet Si l auto apprentissage est correct le voyant B s teint Si le cycle d auto apprentissage ne s est pas d roul correctement le voyant B reste clignotant 2 clignotements Durant...

Page 16: ...lectrique g n ral Fig 19 Cellules photo lectriques Fig 20 Lors de la mise en place des cellules supprimer le pont r alis entre les bornes 1 et 2 Si suppression des cellules il est imp ratif de refair...

Page 17: ...r lancer le cycle d auto apprentissage La porte effectue un cycle Ouverture Fermeture complet Si l auto apprentissage est correct le voyant B s teint Si le cycle d auto apprentissage ne s est pas d ro...

Page 18: ...orange 24 V 15 W Sortie alimentation accessoires 24 V 500 mA max Entr e antenne d port e Oui Entr e batterie de secours Autonomie Oui 24 heures 5 10 cycles suivant porte Temps de charge 72 h FONCTIONN...

Page 19: ...programming 5 Memorising the remote controls for operation in Total opening mode 5 Operating test 6 Using the remote controls 6 Obstacle detection operation 6 Integrated lighting operation 6 Connecti...

Page 20: ...the ground In the case of a removable mobile component it is recommended to store it in the immediate proximity of the door Permanently affix the label concerning the manual repair device near to its...

Page 21: ...ellery bracelet chain etc during installation For drilling and welding operations wear special glasses and appropriate protection Use the appropriate tools Be careful when handling the motorisation sy...

Page 22: ...12 For chain rails only Position each of the bearings in the first hole in the rail outside the end limits Ensure that the bearing is fully pushed in so that the positioning lug protrudes past the ou...

Page 23: ...is correct warning light B goes out If the auto programming cycle was not successful warning light B continues to flash 2 flashes During auto programming If the door is moving the movement is stopped...

Page 24: ...iagram Fig 19 Photoelectric cells Fig 20 When positioning the cells remove the bridge created between terminals 1 and 2 If cells are removed it is essential to recreate the bridge between terminals 1...

Page 25: ...ress B to launch the auto programming cycle The door performs a complete Opening Closing cycle If the auto programming is correct warning light B goes out If the auto programming cycle was not success...

Page 26: ...orange light 24 V 15 W Accessories supply output 24 V 500 mA max Offset aerial input Yes Backup battery input Battery life Yes 24 hours 5 to 10 cycles depending on the door Charging time 72 hours OPE...

Page 27: ...https appceso com...

Page 28: ...19 141 913 419 540 F 913 419 539 Legan s 28916 Madrid apmadrid pujol com Pais Vasco Navarra Rioja Burgos Pol gono Sondikalde Portu Bidea n 4 pabe ll n 6 T 944 712 154 F 944 711 063 Sondika 48150 Vizca...

Reviews: