GDO-10V1 Toro
®
Owner Installation Instructions
Adjusting Safety Obstruction Force
The Safety Obstruction Force is calculated automatically
during setup. Adjusting this is normally only necessitated
by environmental conditions such as windy or dusty areas,
and areas with extreme temperature changes.
WARNING:
Doors requiring over 400N of force to
move must have PE Beams fi tted for safety.
Step 9.1 Force Pressure For Close Cycle.
Navigating To “Current Trips”
Press NEXT or PREV to navigate to the Menu 2
current trips.
Press SET
(Fig. 18)
MENU 2.1: CLOSE Margin is displayed
(Fig. 19)
.
Press OPEN to increase or CLOSE to decrease
value
Press SET to save the new value.
Test the force again as per
“Safety Obstruction
Force test” on page 19.
Step 9.2 Force Pressure For OPEN Cycle.
Navigating To “Current Trips”
Press NEXT to navigate to the Menu 2 current
trips.
Press SET
(Fig. 18)
MENU 2.2: OPEN Margin is displayed
(Fig. 20)
Press OPEN to increase or CLOSE to decrease
value
Press SET to save the new value.
Test the force again as per “Safety Obstruction
Force test” on page 19.
Step 9.3 To Recalculate Force Margins
Reprofi ling is a simplifi ed way of re-learning the
travel characteristic of a previously setup Limit
Switch travel installation. Re-profi ling can be used
when the travel characteristics of the door change
due to mechanical adjustments etc. To initiate a re-
profi le simply locate “MENU 11.2 Reprofi le Travel”
and press SET then follow the prompts. The door
will start to move and re-calculate force margins.
The door can move between the open and close
limit positions up to two (2) times (depending on the
position of the door and the power up condition).
A single beep will be heard once the process is
complete.
Test the force again as per “Safety Obstruction
Force test” on page 19.
1.
2.
3.
4.
5.
6.
1.
2.
3.
4.
5.
6.
a.
b.
•
Adjusting Safety Obstruction Forces
18
fi g
19
fi g
20
fi g
Menu 2
Current Trips
PRESS
1: CLOSE Margin
(Amps) 0.5
PRESS
2: OPEN Margin
(Amps) 0.7
PRESS
Parameter
Min
Max
Default
Step
Unit
Menu No.
CLOSE MARGIN
0.0
2.0
0.5
0.1
AMPS
2
Open Margin
0.0
2.0
0.7
0.1
AMPS
2