Owner Installation Instructions
GDO-10V1 Toro
®
17
Setting Limits Menu 11
12
fi g
PULL DOWN TO
ENGAGE/DISENGAGE
To Desired
CLOSE Limit,
SET
To Desired
OPEN Limit,
SET
14
fi g
Step 6.1 - Setting Travel Limits
WARNING!
Use caution when operating the manual
release with the door open since it may fall rapidly
due to weak or broken springs, or an improperly
balanced door.
CAUTION!
Do not disengage the opener to manual
operation with children, persons or any objects
including motor vehicles within the doorway.
Secure the engage/disengage handle and string
with the accessory supplied in such a manner so
that the string is away from the moving parts.
Move the door to half way open. If necessary,
disengage the opener by pulling the cord down
(Fig.12)
.Re-engage the opener by pulling the cord
down.
Turn on the power to the opener.
The controller will
go through a start up sequence .
After a short delay the MAIN SCREEN
(Fig. 13)
will
be displayed. If this is the fi rst time the GDO-10 is
being used the MAIN SCREEN should enter into
limit set mode and blue close led will be fl ashing. If
the display shows that an input is active then rectify
the situation before continuing with the procedure
for setting the travel limits.
Press and hold the
CLOSE button - the door should start closing.
If the door opens, release the CLOSE
button and press the STOP button once
to change the motor’s direction. Press and
hold the CLOSE button until close position
of the door is reached.
If the door overshoots press the OPEN
button to move the door in the open
direction.
When the door is at the desired close position, press
the SET button to record the close limit position. The
display will change and green open led will start to
fl ash
(Fig. 14)
Press and hold the OPEN button to open the door
When the door is at the desired open position.
Release the OPEN button
If the door overshoots press the CLOSE
button to move the door in the CLOSE
direction.
WARNING!
Once the next step is performed, the
door will automatically close and open to calculate
force settings. Keep persons and objects clear of the
door .
Press the SET button to store the open limit. The
door will now automatically close and open to calculate
the safety obstruction settings. After this, If PE Beams
are installed then the opener can be operated with
the OPEN or CLOSE button on the wall control unit or
from the transmitter else controller will be loaded with
“Safety Close Mode” see page 30.
a.
b.
c.
d.
»
»
f.
g.
»
i.
13
fi g