![AUMA SVC 05.1 Operation Instructions Manual Download Page 20](http://html1.mh-extra.com/html/auma/svc-05-1/svc-05-1_operation-instructions-manual_3016510020.webp)
5.4.3.
Terminal compartment: close
Figure 15: Example: Version S
[1]
Cover
[2]
Screws for cover
[3]
O-ring
[4]
Screws for socket carrier
[5]
Socket carrier
[6]
Cable entry
[7]
Blanking plugs
[8]
Cable gland (not included in delivery)
Short-circuit due to pinching of cables!
Risk of electric shock and functional failures.
→
Carefully fit socket carrier to avoid pinching the cables.
1.
Insert the socket carrier [5] into the cover [1] and fasten with screws [4].
2.
Clean sealing faces of cover [1] and housing.
3.
Check whether O-ring [3] is in good condition, replace if damaged.
4.
Apply a thin film of non-acidic grease (e.g. petroleum jelly) to the O-ring and
insert it correctly.
5.
Fit cover [1] and fasten screws [2] evenly crosswise.
6.
Fasten cable glands [8] applying the specified torque to ensure the required
enclosure protection.
5.5.
Earth connection, external
The housing is equipped with an external earth connection (U-bracket) to integrate
the device in equipotential earth bonding.
20
SVC 05.1 – SVC 07.5/ SVCR 05.1 – SVCR 07.5
Electrical connection