9.5.
Test run
Perform test run only once all settings previously described in the Commis-
sioning clause have been performed.
9.5.1 Rotational direction check
1. Move actuator manually to intermediate position or to sufficient distance
from end position.
2. Set selector switch to position
Local control
(LOCAL).
3. Operate push button CLOSE and observe the direction of rotation.
4. Switch off before reaching the end position.
For actuators equipped with indicator disc
Ò
Observe direction of rotation on the indicator disc.
The direction of rotation is correct, if: The actuator moves in direction
CLOSE while the indicator disc turns counterclockwise.
51
Multi-turn actuator SAExC 07.1 – SAExC 16.1/SARExC 07.1 – SARExC 16.1
Non-Intrusive
Operation instructions
with actuator controls AUMATIC ACExC 01.1 Profibus DP
Valve damage due to incorrect direction of rotation!
Ò
If the direction of rotation is wrong, switch off immediately (press STOP).
Ò
Eliminate the cause, e.g. correct phase sequence for wall bracket cable set.
Ò
Repeat test run.
0
I
I
auma
NOTICE